Contacts, documents and full notice history are available with a subscription.
Solicitation Expired 3 notices 11 documents

Y1NB--FY26: (PROJ: 546-23-105) Create Redundancy Capacity in Chiller Plant System/ Chilled & Condensed Water System Repair/Replacement 36C24826R0028

Solicitation 36C24826R0028 Copied Notice ID 964a3e2c32294ffa97119078cf6787ad Copied VETERANS AFFAIRS, DEPARTMENT OF — 248-NETWORK CONTRACT OFFICE 8 (36C248)
SAM.gov
Posted
Mar 06, 2026
Deadline
Apr 13, 2026
Set-aside
None
NAICS
236220
PSC
Y1NB

Summary

AI-generated · Mar 09, 2026

Provide construction services to create redundant capacity in the building’s chilled and condenser water systems and their auxiliary components. Key elements include adding a 1,250-ton water-cooled chiller on the second-floor addition, installing a two-cell cooling tower on the roof, and placing the electrical gear for the new equipment on the third level. The fourth level will house an additional electrical generator that is to be procured under a separate project. Site preparation per the 100% design, narrative, addenda, and specifications is required, including demolition/removal of existing structures and furnishing all labor and materials to complete the work per the SOW.

This is a full construction effort to implement redundancy for the chiller plant and integrate with existing systems, with the generator portion handled in a separate project. The period of performance is a long-term construction effort from notice to proceed.

The contractor shall provide construction services in accordance with the Statement of Work for Project Number: 546-23-105 Create Redundancy Capacity in Chiller Plant System. The primary objective of this project is to provide redundant capacity for the existing chilled and condenser water systems and their associated auxiliary systems. This includes adding a new water-cooled chiller, sized for 1,250 tons, on the second level of the building addition and installing a new two-cell cooling tower on the roof. Additionally, electrical gear supporting the new equipment will be located on the third level, and the fourth level will be the housing for an additional Electrical Generator (to be procured under a separate project). The Contractor shall prepare the site for building operations in accordance with the 100% Design, Narrative, Addendum, and Specifications. This includes demolition and removal of existing structures, furnishing labor and materials, and completing all tasks as per this Statement of Work (SOW). Period of Performance (POP) Dates: 1095 Calendar Days from the notice to proceed (NTP). PRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction. PRODUCT/SERVICE CODE: Y1NB - Construction of Heating and Cooling Plants.

From Solicitation posted on Mar 06, 2026

The contractor shall provide construction services in accordance with the Statement of Work for Project Number: 546-23-105 Create Redundancy Capacity in Chiller Plant System. The primary objective of this project is to provide redundant capacity for the existing chilled and condenser water systems and their associated auxiliary systems. This includes adding a new water-cooled chiller, sized for 1,250 tons, on the second level of the building addition and installing a new two-cell cooling tower on the roof. Additionally, electrical gear supporting the new equipment will be located on the third level, and the fourth level will be the housing for an additional Electrical Generator (to be procured under a separate project). The Contractor shall prepare the site for building operations in accordance with the 100% Design, Narrative, Addendum, and Specifications. This includes demolition and removal of existing structures, furnishing labor and materials, and completing all tasks as per this Statement of Work (SOW). Period of Performance (POP) Dates: 1095 Calendar Days from the notice to proceed (NTP). PRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction. PRODUCT/SERVICE CODE: Y1NB - Construction of Heating and Cooling Plants.

From Solicitation posted on Apr 16, 2026

The contractor shall provide construction services in accordance with the Statement of Work for Project Number: 546-23-105 Create Redundancy Capacity in Chiller Plant System. The primary objective of this project is to provide redundant capacity for the existing chilled and condenser water systems and their associated auxiliary systems. This includes adding a new water-cooled chiller, sized for 1,250 tons, on the second level of the building addition and installing a new two-cell cooling tower on the roof. Additionally, electrical gear supporting the new equipment will be located on the third level, and the fourth level will be the housing for an additional Electrical Generator (to be procured under a separate project). The Contractor shall prepare the site for building operations in accordance with the 100% Design, Narrative, Addendum, and Specifications. This includes demolition and removal of existing structures, furnishing labor and materials, and completing all tasks as per this Statement of Work (SOW). Period of Performance (POP) Dates: 1095 Calendar Days from the notice to proceed (NTP). PRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction. PRODUCT/SERVICE CODE: Y1NB - Construction of Heating and Cooling Plants.

From Solicitation posted on Apr 20, 2026

Notice history

3
  1. Solicitation Posted Mar 06, 2026
  2. Solicitation Posted Apr 16, 2026
    • Response Deadline: Apr 13, 2026Apr 21, 2026
  3. Solicitation LATEST Posted Apr 20, 2026
    • Response Deadline: Apr 21, 2026Apr 27, 2026

Details

Solicitation number 36C24826R0028
Notice ID 964a3e2c32294ffa97119078cf6787ad
Notice type Solicitation
Product / Service (PSC) Y1NB
NAICS 236220
Place of performance Florida
Archive date Aug 05, 2026

Award Information

Not yet awarded

Contacts

primary
Aldwyn Singleton

Contracting Officer

Email

Phone

secondary
Jean Olivier Pierre

Email

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
248-NETWORK CONTRACT OFFICE 8 (36C248)

Place of Performance

Florida 33125
USA

Dates

Posted Mar 06, 2026 5 months ago
Last Updated Aug 06, 2026 2 days ago
Due Apr 13, 2026 3 months ago