Contacts, documents and full notice history are available with a subscription.
Award Notice SBA 1 notice

XTLF 15-1018 Repair AA and E Storage at F527 FA3029-0003

Solicitation FA3029-0003 Copied Notice ID f66c69fc2a4348f68be09c8117d4413d Copied DEPT OF DEFENSE — FA3029 71 FTW CVC
SAM.gov
Posted
Oct 02, 2025
Deadline
No deadline
Set-aside
SBA
NAICS
236220
PSC
Z2JZ

Summary

AI-generated · Oct 09, 2025

Renovate building 527 to bring AA&E storage in line with UFC 04-026-01 and MIL-HNDBK 1013/1A, addressing the deviation VANCE AFB 97-01. The project focuses on strengthening the storage room and ensuring compliance with security and safety standards so the facility no longer poses risk to the base.

Scope includes reinforcing the AA&E storage room by adding steel and plywood to surrounding interior walls and ceiling, removing and reinstalling fixtures on the new wall/ceiling faces, and replacing the entry door with a compliant one. Window fasteners will be swapped for tamper-resistant types, interior electrical circuits dedicated to the room will be relocated to a new panel outside the room for better emergency access, and AA&E Risk Categories II–IV must be stored in a structure with at least 10 minutes of forced-entry resistance against threat severity level III. Without the renovation, the building would not meet UFC/MIL-HNDBK requirements and would remain a safety risk to the base.

This service will renovate building 527 to comply with UFC 04-026-01 and MIL-HNDBK 1013/1A. The building requires minor renovations to eliminate deviation request VANCE AFB 97-01. The scope of this work includes the reinforcement of the existing AA&E storage room by adding steel and plywood layers to surrounding interior walls and ceiling. Existing fixtures will be removed and reinstalled on the new wall and ceiling faces. Entry door will be replaced with a compliant door, and window fasteners will be replaced with compliant tamper-resistant fasteners. Circuits on the interior electrical panel dedicated to other areas of the facility will be relocated to a new panel outside the room, providing better access to emergency personnel. AA&E Risk Categories II through IV must be stored in a structure with a minimum forced entry resistance of 10 minutes against threat severity level III. If facility does not receive renovation, the building will not meet UFC and MIL-HNDBK code and remain potential risk of safety to the base.

From Award Notice posted on Oct 02, 2025

Notice history

1
  1. Award Notice LATEST Posted Oct 02, 2025

Details

Solicitation number FA3029-0003
Notice ID f66c69fc2a4348f68be09c8117d4413d
Award number FA302925C0005
Notice type Award Notice
Product / Service (PSC) Z2JZ
NAICS 236220
Place of performance Enid, Oklahoma
Archive date Oct 09, 2025

Award Information

Awardee
1
Total Awarded
$437,129.23
Award Date
Sep 24, 2025

Award Notices

XTLF 15-1018 Repair AA and E Storage at F527 View Notice

Posted: Oct 02, 2025

This service will renovate building 527 to comply with UFC 04-026-01 and MIL-HNDBK 1013/1A. The building requires minor renovations to eliminate deviation request VANCE AFB 97-01. The scope of this work includes the reinforcement of the existing AA&E storage room by adding steel and plywood layers t...

Awardees

Company Name UEI CAGE Code Location
WALDROP CONSTRUCTION INC T53ANRCADY13 59MY0 Oklahoma City, OK

Documents

No files available

View on SAM.gov

Contacts

primary
Alexis Bishop

Email

Phone

secondary
Thomas Patton

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE AIR FORCE
AIR EDUCATION AND TRAINING COMMAND
FA3029 71 FTW CVC

Place of Performance

Enid, Oklahoma 73705
USA

Dates

Posted Oct 02, 2025 10 months ago
Last Updated Aug 06, 2026 2 days ago
Awarded Sep 24, 2025 10 months ago