Patrick SFB, Florida - DECA Commissary Architectural and Refrigeration Upgrades GNFR-FC-PAT-25-25152
Summary
AI-generated · Nov 26, 2025Patrick SFB, Florida DECA Commissary upgrades require alterations to renovate and modernize the commissary, including architectural and refrigeration upgrades with electrical, mechanical, and plumbing improvements, restroom renovations, and new LED lighting and décor to meet DeCA standards. The project also includes modifications to prefabricated insulated coolers and freezers, new floor finishes (ceramic tile in restrooms, VCT in admin/entry areas, polished concrete on the main sales floor), wall painting, suspended acoustical ceiling panels and gypsum wallboard, replacement of display cases throughout the sales area, and updates to the central refrigeration system and RMCS. Additionally, repair of the roofing system for new rooftop mechanical units and replacement of the fire alarm system are required.
To bid, refer to the provided solicitation portal; amendments will be posted there and must be acknowledged when submitting a proposal.
GNFR-FC-PAT-25-25152 AAFES Project Number: 3784-25-000011 / DECA Project Number: EA17MI02 Patrick SFB, Florida DECA Commissary Architectural and Refrigeration Upgrades. This project makes alterations to the existing Patrick SFB Commissary as follows: a. Architectural and refrigeration upgrades including electrical upgrades and modifications, mechanical and plumbing improvements and modifications, restroom renovations, new LED lighting throughout and new Dcor package to meet the current DeCA standards b. Modifications to prefabricated insulated coolers and freezers; floor finishes in various areas to include new ceramic tile in the restrooms, VCT in the admin and entry areas and polished concrete in the main sales floor; wall finishes of paint; ceiling finishes of suspended acoustical panels and gypsum wallboard c. Replace display cases indicated throughout Sales Area, including the central Refrigeration system and Refrigeration Monitoring Control System (RMCS) d. Repair of roofing system at new rooftop mechanical units e. Replace Fire Alarm system In order to participate in this solicitation, please refer to link provided. Any and all amendments will be posted on our website, and must be acknowledged, when submitting a proposal. https://odin.aafes.com/ConstructionSolicitations/
From Solicitation posted on Nov 25, 2025Notice history
1Details
Award Information
Not yet awarded
Contacts
Phone
Agency
Place of Performance
USA