Summary
AI-generated · Feb 11, 2026Repairs and maintenance of a single vertical aboveground storage tank (Tank 5) at Facility 2186, Joint Base Langley-Eustis. Tank 2186 Repair (R) covers a broad scope: replace the tank roof; repair issue, receipt, and low-suction piping; remove mechanical tape gauge; remove and replace spiral stairs; repair the stilling well; re-install the tank’s ATG system; repair shell manholes; replace tank chime sealant; repair the containment area and tank grounding; repair weld spacing; and provide the tank data plate. Tank 2186 Maintenance (M) covers coating replacement on tank and piping, provide tank strapping charts, and perform the final API 653 inspection.
This is a sources-sought notice to identify capable contractors with experience in aboveground storage tank repairs and API 653 inspections for a military facility, outlining both repair and maintenance tasks and the need to complete the specified inspections and documentation. No further details are provided here beyond the described scope.
This project involves repairs and maintenance of one vertical aboveground storage tank ? Facility 2186 (Tank 5) at Joint Base Langley-Eustis. All Work Complete for Tank 2186 Repair (R) including replace tank roof, repair issue piping, repair receipt piping, repair low suction piping, remove mechanical tape gauge, remove and replace spiral stairs, repair stilling well, re-install tank ATG system, repair shell manholes, replace tank chime sealant, repair containment area, repair tank grounding, repair weld spacing, and provide tank data plate. All Work Complete for Tank 2186 Maintenance (M) including replace tank and piping coatings, provide tank strapping charts, and perform final API 653 inspection.
From Sources Sought posted on Feb 10, 20262. The purpose of this amendment is to extend the closing date to 11 March 2026.1. This project involves repairs and maintenance of one vertical aboveground storage tank ? Facility 2186 (Tank 5) at Joint Base Langley-Eustis. All Work Complete for Tank 2186 Repair (R) including replace tank roof, repair issue piping, repair receipt piping, repair low suction piping, remove mechanical tape gauge, remove and replace spiral stairs, repair stilling well, re-install tank ATG system, repair shell manholes, replace tank chime sealant, repair containment area, repair tank grounding, repair weld spacing, and provide tank data plate. All Work Complete for Tank 2186 Maintenance (M) including replace tank and piping coatings, provide tank strapping charts, and perform final API 653 inspection.
From Sources Sought posted on Mar 06, 2026Notice history
2-
-
Sources Sought LATEST Posted Mar 06, 2026View changes (2)
- Description: Description was updated
- Response Deadline: Mar 03, 2026 → Mar 11, 2026
Details
Award Information
Not yet awarded
Contacts
Phone
Agency
Place of Performance
23665