J--GC26 FIRE ALARM SYSTEM REPLACEMENT 140R4026R0010
Summary
AI-generated · Feb 25, 2026Remove, dispose of, and replace the existing fire detection and alarm systems at three locations (Glen Canyon Powerplant and associated facilities near Page, AZ; Carl Hayden Visitor Center; and Facility Workshop Building). Design, furnish, and install a new, integrated fire detection and alarm system, including removal of old interconnection wiring, and supply a laptop to operate and monitor the system. The new system must communicate with and be integrated into existing fire alarm panels at the Government Project Warehouse Building, Carl Hayden Visitor Center, and Facility Workshop, and a hybrid water mist fire suppression system must be installed in the powerplant computer room. The project also requires modifying 120-volt electrical distribution for the new equipment, integrating with elevators, stairwell pressurization, generator CO release, transformer deluge, and HVAC systems; and testing and commissioning all components while planning work to minimize interruptions to critical plant loads.
Respondents should demonstrate relevant experience with similar fire alarm and suppression projects, and provide a capability statement and applicable certifications (e.g., NICET, manufacturer certifications). Include the company name, U.S. entity ID, SAM.gov registration status, and overall business size; indicate a recommended NAICS code if different. This is a market-research Sources Sought notice and not a solicitation; submit responses by the stated deadline and direct any questions to the contract specialist.
GC26 FIRE ALARM SYSTEM REPLACEMENT Sources Sought Notice Fire Detection and Alarm System Upgrade Glen Canyon Powerplant and Associated Facilities This is a Sources Sought Notice for market research purposes only. The Government is seeking qualified and capable contractors to perform the following work. This is NOT a solicitation for proposals or quotations. Project Location: Glen Canyon Powerplant, approximately 3 miles northwest of Page, Arizona, in Coconino County. Principal Components of Work: Remove, dispose of, and replace existing fire detection and alarm systems. Remove existing interconnection wiring for the fire detection and alarm system. Design, furnish, and install a new fire detection and alarm system at three locations: Glen Canyon Powerplant, Carl Hayden Visitor Center, and Facility Workshop Building. Provide a new laptop computer compatible with and able to operate and monitor the system. Communicate and integrate alarm signals from fire alarm panels at the Government Project Warehouse Building, Carl Hayden Visitor Center, and Facility Workshop. Design, furnish, and install a hybrid water mist fire suppression system in the powerplant computer room. Modify 120-volt distribution systems to accommodate new fire detection and alarm equipment. Integrate new fire alarm system with existing elevators, stairwell pressurization system, generator CO release system, transformer deluge system, and HVAC systems. Test and commission all systems. Plan and sequence work to eliminate or minimize interruptions of service to critical station loads within the plant. NAICS Code: 238210 Electrical Contractors and Other Wiring Installation Contractors (verify applicability). Business size standard is $19.0M Response Requirements: Company name, address, and point of contact Unique Entity ID Business size (Small Business, 8(a), HUBZone, SDVOSB, etc.) Relevant experience with similar fire alarm and suppression system projects Capability statement demonstrating ability to perform the work Applicable certifications (e.g., NICET, manufacturer certifications) Registered in SAM.gov (yes/no) Recommended North American Industry Code (NAICS CODE) if other the 238210. Submission Deadline: Please provide the responses to this source sought by March 10st 2026. Questions regarding this source sought shall be directed to Lisa Laughbon Contract Specialist at llaughbon@usabr.gov Disclaimer: This notice is for planning purposes only and does not commit the Government to any contractual action.
From Sources Sought posted on Feb 24, 2026GC26 FIRE ALARM SYSTEM REPLACEMENT The purpose of this amendment is to extend the closing date for the solicitation.
From Solicitation posted on Jul 13, 2026GC26 FIRE ALARM SYSTEM REPLACEMENT The purpose of this amendment is to post the questions and Answers that have been submitted to the Contracting Officer.
From Solicitation posted on Aug 07, 2026Notice history
3-
-
Solicitation Posted Jul 13, 2026View changes (4)
- Description: Description was updated
- Notice Type: Sources Sought → Solicitation
- Response Deadline: Mar 10, 2026 → Jul 28, 2026
- Status: Inactive → Active
-
Solicitation LATEST Posted Aug 07, 2026View changes (2)
- Description: Description was updated
- Response Deadline: Jul 28, 2026 → Aug 18, 2026
Details
Award Information
Not yet awarded
Contacts
Phone
4062477338