HVAC Replacement at USCG STA Washington 30252PR260000011
Summary
AI-generated · Apr 24, 2026Replace HVAC at USCG STA Washington per the attached SOW, including performing heat-load calculations using the existing ductwork to determine the appropriate size for indoor and outdoor units, and providing the owner with a written copy of those calculations. If the heat-load results require ductwork changes, the contractor must modify/resize and install them. Install a new EPA-approved A2L refrigerant system (R-454B or R-32, preferably R-454B); pull an entirely new line-set from the heat pump to the air handler, including new suction and liquid lines, and install a new liquid-line drier for each circuit indoors near the air handler to prevent corrosion.
Remove and dispose of the current indoor and outdoor units (the units will be without refrigerant during removal). Replace wiring and conduit from the existing service disconnects to the new equipment, and replace any corroded or damaged conduit or wiring discovered during demolition. If any disconnects are not fused, replace them with new fused disconnects. Replace all thermostat control wiring inside and outside with UV-rated wire, and provide and replace the existing thermostat to match the system function.
HVAC replacemet in accordance with the Attached SOW, to include: a. Determine heat load calculations for the HVAC system using installed ducting system. Use heat load calculations to determine an appropriate size/capacity for indoor and outdoor units utilizing installed ducting. Provide owner with a written copy of load calculations. If it is determined that any duct work needs to be modified, changed or resized in any way due to the heat load calculations, contractor shall provide and install. New unit shall be EPA approved A2L based refrigerant either R-454B or R-32, preferably R-454B. Contractor shall pull and entire new line-set to include new suction lines and liquid lines that run from heat pump to air handler. Contractor shall install a new liquid line drier for each circuit and locate the new liquid line drier indoors near the air handler to prevent unnecessary corrosion from outside elements. b. Remove and dispose of the current outdoor and indoor units. Unit will not have refrigerant in it. c. Replace wiring and conduit from existing service disconnects to new pieces of equipment. Replace any corroded or damaged conduit or wiring found during the demo of existing equipment. If disconnects are not fused, then contractor shall replace any and all associated disconnects with new fused ones. d. Replace all thermostat control wiring inside and outside with new UV rated wire. Provide and replace existing thermostat to match the system function.
From Combined Synopsis/Solicitation posted on Apr 23, 2026Notice history
1-
Combined Synopsis/Solicitation LATEST Posted Apr 23, 2026
Details
Award Information
Not yet awarded