Contacts, documents and full notice history are available with a subscription.
Solicitation Expired 2 notices 3 documents

FY25 DHA SRM FACILITY REPAIRS, BUILDING 1585, YOKOTA AIR BASE, JAPAN W912HV25B0005

Solicitation W912HV25B0005 Copied Notice ID a5682f7fd1d249288ba850ebf1336a48 Copied DEPT OF DEFENSE — W2SN ENDIST JAPAN
SAM.gov
Posted
Jul 25, 2025
Deadline
Aug 22, 2025
Set-aside
None
NAICS
236220
PSC
Z2DB

Summary

AI-generated · Aug 24, 2025

Replace the HVAC system for Building 1585 at Yokota Air Base, including the building chiller and pumps, five Central Station Air Handling Units with associated Variable Air Volume boxes, installation of a new hydronic reheat system, and implementation of new DDC controls. Modernize the sterile processing department by moving it from the second to the first floor and creating a new three-room standard template for decontamination, sterile assembly, and sterile storage; the existing sterilization space will be repurposed for a different use.

Access all project documents through the PIEE website; amendments have updated specifications, drawings, and RFIs, and include revised site visit details.

25 July 25: Amendment 0002 posted. Revised specifications, drawings, and answered RFIs. Please read amendment for details. 14 May 25: Amendment 0001 posted Site Visit Date has changed to 27 May 25. Please read amendment for details. This project will replace the HVAC system including the building chiller and associated pumps, 5 Central Station Air Handling Units and associated Variable Air Volume Boxes, installation of a new hydronic reheat system, and implementation of new DDC Controls along with modernizing the sterile processing department for building 1585. A new layout for the sterilization department will provide a three-room standard template for decontamination, sterile assembly and sterile storage. The sterilization department will move from the second floor to the first floor. The existing sterilization department will be converted to a different use. Please download all files in PIEE Website.

From Solicitation posted on Jul 25, 2025

28 August 25: Bid opened and OF 1419 Bid Abstract posted. 31 July 25: Extended bid due date to 28 Aug 25. 25 July 25: Revised specifications, drawings, and answered RFIs. 14 May 25: Site Visit Date has changed to 27 May 25. Please read amendment for details. This project will replace the HVAC system including the building chiller and associated pumps, 5 Central Station Air Handling Units and associated Variable Air Volume Boxes, installation of a new hydronic reheat system, and implementation of new DDC Controls along with modernizing the sterile processing department for building 1585. A new layout for the sterilization department will provide a three-room standard template for decontamination, sterile assembly and sterile storage. The sterilization department will move from the second floor to the first floor. The existing sterilization department will be converted to a different use. Please download all files in PIEE Website.

From Solicitation posted on Aug 28, 2025

Notice history

2
  1. Solicitation Posted Jul 25, 2025
  2. Solicitation LATEST Posted Aug 28, 2025
    • Description: Description was updated
    • Response Deadline: Aug 22, 2025Aug 28, 2025

Details

Solicitation number W912HV25B0005
Notice ID a5682f7fd1d249288ba850ebf1336a48
Notice type Solicitation
Product / Service (PSC) Z2DB
NAICS 236220
Place of performance YOKOTA AB
Archive date Jul 25, 2026

Award Information

Not yet awarded

Contacts

primary
Charles Qi

Email

secondary
Ruben Romero

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE ARMY
US ARMY CORPS OF ENGINEERS
ENGINEER DIVISION PACIFIC OCEAN
W2SN ENDIST JAPAN

Place of Performance

YOKOTA AIR BASE, TOKYO, JAPAN
YOKOTA AB
JPN

Dates

Posted Jul 25, 2025 1 year ago
Last Updated Aug 06, 2026 1 day ago
Due Aug 22, 2025 11 months ago