FLUID CHILLER W912CH25QA017
Summary
AI-generated · Aug 24, 2025Fluid chiller rated at 61,000 BTU/hr requiring 1 1/4" NPT inlet/outlet piping, with a minimum 26-gallon reservoir and an outlet temperature of 50°F. Dimensions are 42" L x 28" W x 66" H and a dry weight around 760 lb, with a footprint no larger than 42" x 28" and a height under 80"; designed for year-round outdoor operation.
Must include a chiller pump capable of at least 5 GPM continuous duty with stainless-steel construction, non-ferrous piping, and a digital temperature display/control. Pump must meet 18 GPM at 38 PSI. Refrigeration uses R407c and a highly efficient scroll compressor. Acceptable electrical configurations are 230/1, 230/3, or 460/3 with rated load of 11 A at 460/3. Provide at least 1 year of parts and labor warranty.
FLUID CHILLER:61,000 BTU?s / Hr Inlet /Outlet Piping needs to be 11/4? NPT. Pump Specifications must be 18 GMP at 38 PSI. Voltage / Phase must be 230/1, 230/3, 460/3Rated load amps at 11A@460/3. Dimensions must be 42?L X 28?W X 66?H. Dry Weight must be approximately 760 lbs. Chiller outlet temp should be 50 degrees Fahrenheit. Must have at least a 26-gallon reservoir. Chiller pump must be rated for no less than 5gpm. Pump must be continuous duty and of stainless-steel construction. All piping must be non-ferrous. Shall have a footprint no larger than 42? x 28? and less than 80? in height. Shall have a digital display for temperature display and control. Shall use R407c refrigerant. Shall have a highly efficient scroll compressor. Shall include at least a 1-year parts and labor warranty. Must be rated to operate outside all year.
From Combined Synopsis/Solicitation posted on Jun 17, 2025Notice history
1Details
Award Information
Not yet awarded
Contacts
Phone