Byron White Courthouse Barrier Replacement EQ8PSCC-25-0023

Solicitation EQ8PSCC-25-0023 Copied Notice ID bbcf4a15f62c41cb8ca9c993e7742945 Copied GENERAL SERVICES ADMINISTRATION — PBS R8 ACQUISITION MANAGEMENT DIVISION
SAM.gov
Posted
Feb 23, 2026
Deadline
Mar 06, 2026
Set-aside
SBA
NAICS
236220
PSC
Z2AA

Summary

AI-generated · Feb 24, 2026

Demolish and remove the existing Delta wedge barriers at the Byron White Courthouse garage entrance and exit, and design and construct a new Active Vehicular Barrier (AVB) system using HySecurity StrongArm M30 and M50 barriers to secure the garage, including the necessary supporting infrastructure.

The current wedge barriers are inoperable due to power issues and heavy rust, and they lack safety devices to protect life and property. A HySecurity StrongArm drop arm is required for reliable operation in these conditions. The project is design-build and requires that all work be performed by USMS-approved security installers.

This project is a total small business set a side. The General Services Administration is intiating a design build project to demolish and remove the existing Delta wedge barriers at the garage entrace and exit location located at the Bryon White Courthouse. Upon complete removal of the wedge barriers and components, installation of Hysecurity StrongArm M30 and M50 barriers shall be installed to provide a secure environment to the garage. Currently the existing wedge barriers are inoperable due to current power issues and heavy rust corrosion. The existing setup also does not include safety devices to ensure the safe operation of the wedge barriers to life and property. The USMS require Hysecurity Strong Arm drop arm to provide acceptable operation due to the environmental conditions and proven operation. This project includes a design and construction of a new Active behicular barrier (AVB) system and supporting infrastructure at the garage entrace and exist. Only USMS approved securtiy installers can be used on this project.

From Presolicitation posted on Feb 23, 2026

This project is a total small business set a side. The General Services Administration is intiating a design build project to demolish and remove the existing Delta wedge barriers at the garage entrace and exit location located at the Bryon White Courthouse. Upon complete removal of the wedge barriers and components, installation of Hysecurity StrongArm M30 and M50 barriers shall be installed to provide a secure environment to the garage. Currently the existing wedge barriers are inoperable due to current power issues and heavy rust corrosion. The existing setup also does not include safety devices to ensure the safe operation of the wedge barriers to life and property. The USMS require Hysecurity Strong Arm drop arm to provide acceptable operation due to the environmental conditions and proven operation. This project includes a design and construction of a new Active behicular barrier (AVB) system and supporting infrastructure at the garage entrace and exist. Only electrical contractor is required to be USMS approved.

From Presolicitation posted on Feb 24, 2026

Notice history

2
  1. Presolicitation Posted Feb 23, 2026
  2. Presolicitation LATEST Posted Feb 24, 2026
    • Description: Description was updated

Details

Solicitation number EQ8PSCC-25-0023
Notice ID bbcf4a15f62c41cb8ca9c993e7742945
Notice type Presolicitation
Product / Service (PSC) Z2AA
NAICS 236220
Place of performance Denver, Colorado
Archive date Mar 21, 2026

Award Information

Not yet awarded

Documents

No files available

View on SAM.gov

Contacts

primary
Corey J Roundfield

Email

Phone

Agency

GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDINGS SERVICE
PBS R8 ACQUISITION MANAGEMENT DIVISION

Place of Performance

Denver, Colorado
USA

Dates

Posted Feb 23, 2026 5 months ago
Last Updated Aug 06, 2026 1 day ago
Due Mar 06, 2026 5 months ago