Contacts, documents and full notice history are available with a subscription.
Solicitation SBA Expired 1 notice

B16 Generator PLC Upgrade W50S7X26BA001

Solicitation W50S7X26BA001 Copied Notice ID 3159f3f843b94d24b76db96579b4cea2 Copied DEPT OF DEFENSE — W7M9 USPFO ACTIVITY KSANG 184
SAM.gov
Posted
Mar 19, 2026
Deadline
Apr 22, 2026
Set-aside
SBA
NAICS
238210
PSC
J059

Summary

AI-generated · Mar 20, 2026

Upgrade the B16 Generator PLC at 52010 Jayhawk Drive, Building 16, McConnell AFB, Wichita, KS. A single firm-fixed-price contract will cover all labor, transportation, materials, tools, equipment, appliances, and supervision to inspect, troubleshoot, and repair or replace the generator PLC controls; restore the PLC to its original installation parameters; verify restored generator operations and communications; and perform a function check of operations in both standalone and parallel modes. Base bid and an option are included; the option would install a Hot Switch Bypass to eliminate single points of failure and allow the current HMI to communicate with each generator’s PLCs.

The prime contractor must subcontract with 3E Company, Kohler’s OEM regional representative. The contract duration is 60 calendar days after notice to proceed, including inspection and punch list. This project is 100% set aside for small businesses. Funds are not currently available for this acquisition, and no contract will be awarded until funds are available.

The Kansas National Guard intends to issue an Invitation for Bids to award a single firm fixed-price contract for services, non-personal, to provide all plant, labor, transportation, materials, tools, equipment, appliances and supervision necessary for the upgrade B16 Generator PLC located at 52010 Jayhawk drive, building 16, McConnell AFB, Wichita Kansas. Line Items will include the Base Bid and an Option. The Base bid work shall consist of but is not limited to the following: Inspect, troubleshoot, and repair or replace generator PLC controls. The contractor is to troubleshoot and repair PLC to original installation parameters, verify restored PLC Generator set operations and communication and ensure repairs with a function check of generator operations in standalone and parallel modes. There is an option line to install a Hot Switch Bypass to remove the single points of failure and allow the current HMI to communicate all operations to each individual generators PLCs. NOTE: Prime contractor is required to subcontract with 3E Company (electrical Engineering and Equipment Co.) since they are the designated OEM regional representative of Kohler. The contract duration will be 60 calendar days after notice to proceed to include inspection and punch list. This project is set aside 100% for Small Businesses. The North American Industry Classification System (NAICS) Code is 238210, with a small business size standard of $19,000,000. The magnitude of construction is between $500,000 and $1,000,000. Funds are not presently available for this acquisition. No contract will be made until appropriate funds are made available.

From Solicitation posted on Mar 19, 2026

Notice history

1
  1. Solicitation LATEST Posted Mar 19, 2026

Details

Solicitation number W50S7X26BA001
Notice ID 3159f3f843b94d24b76db96579b4cea2
Notice type Solicitation
Product / Service (PSC) J059
NAICS 238210
Archive date May 08, 2026

Award Information

Not yet awarded

Documents

No files available

View on SAM.gov

Contacts

primary
Joshua Kingori

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE ARMY
NATIONAL GUARD BUREAU
JFHQ USPFO KS
USPFO KS PROCUREMENT
W7M9 USPFO ACTIVITY KSANG 184

Place of Performance

52010 Jayhawk drive, building 16, McConnell AFB, Wichita Kansas
67221

Dates

Posted Mar 19, 2026 4 months ago
Last Updated Aug 06, 2026 1 day ago