7510--Document Scanners 36C24826Q0609
Summary
AI-generated · Apr 21, 2026A potential procurement is being explored for a high-speed document scanner to support the C. W. Bill Young (Bay Pines) VA Health Care System’s Medical Records Scanning section, aimed at reducing a scanning backlog and increasing productivity. The scanner will connect to VA workstations and the VA VISTA software to capture patient medical records, including Community Care exams and other VA records, to help deliver timely patient care.
Respondents should offer brand-name or equal equipment that meets or exceeds the specified characteristics for the Ricoh fi-8950 or an equivalent device. Required features include ADF/Manual Feed, duplex scanning at up to 300 ipm (200/300 dpi) and simplex speeds around 115–150 ppm (depending on orientation and dpi), 600 dpi optical resolution, 50–600 dpi output (up to 1,200 dpi via driver), color/grayscale/monochrome outputs, CIS x2 image sensors with RGB LED lighting, support for documents up to 304.8 x 431.8 mm and down to 48 x 70 mm, and selectable white/black backgrounds. No additional training is required; a standard manufacturer warranty is requested (extended warranties requiring advance payment are not accepted). Delivery is to be made after receipt of a purchase order to the Bay Pines address. This is a market-sounding activity to assess SDVOSB capacity and may lead to a SDVOSB-set-aside, or a VOSB/SB set-aside if SDVOSB responses are insufficient; capability statements should be submitted via email.
Good day, SDVOSB s, VOSB s, SB s This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue a solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SDVOSB businesses. This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside in which case all interested parties responding shall be eligible to compete. Please direct reply in the affirmative via email if you are interested and can provide the required service/product for this requirement. Please provide your capability statement, I will accept responses for this Sources Sought until the 30th of April, 2026 at 14:00, thanks. STATEMENT OF NEED GENERAL: C. W. Bill Young (Bay Pines) VAHCS 10000 Bay Pines Blvd, Bay Pines, Florida 33744, has a requirement for the Business Office Service, Medical Records Scanning section to increase productivity and relieve a scanning backlog. BACKGROUND: The C.W. Bill Young has a requirement to reduce scanning backlog (Action Item) PURPOSE: Scanners will connect to VA Workstations and connects to VA VISTA software to accommodate the scanning of patient medical records.. These records include Community care exams, other VA s medical records, and are a crucial component in delivering patient care. SCOPE: C. W. Bill Young (Bay Pines) is requesting contractors provide brand name or equal equipment that meets or exceed the physical, functional and performance of the listed salient characteristics in this section. The equipment feature is essential to the technical requirements to meet the need of the government. PHYSICAL CHARACTERISTICS: Equipment must have the physical characteristics to enable the government to perform the capabilities: RICOH fi-8950: ADF (Automatic Document Feeder)/Manual Feed, Duplex Scanning Speed (A4 Landscape)(Color /Grayscale / Monochrome )Simplex: 150 ppm (200/300 dpi) Duplex : 300 ipm (200/300 dpi) Scanning Speed (A4 Portrait)(Color /Grayscale /Monochrome ) Simplex: 115 ppm (200/300 dpi) Simplex: 115 ppm (200/300 dpi) Image Sensor Type CIS x 2 (front x 1, back x 1) Light Source RGB LED x 4 (front x 2, back x 2) Optical Resolution 600 dpi Output Resolution (Color/Grayscale/Monochrome) 50 to 600 dpi (adjustable by 1 dpi increments), 1,200 dpi (driver) Output Format Color: 24-bit, Grayscale: 8-bit, Monochrome: 1-bit Background Colors White/Black (selectable) Document Size Max 304.8 x 431.8 mm Document Size Min 48 x 70 mm FUNCTIONAL AND PERFORMANCE CHARACTERISTICS: Equipment must provide the functional and performance capability as listed above in section in above. SOFTWARE: N/A TRAINING: Government will not require additional training. WARRANTY OF EQUIPMENT: Government requirement for standard manufacturer industry warranty term. Government does not accept extended warranty, which requires advance payment. DELIVERY SCHEDULE: All items to be delivered after receipt of purchase order PLACE OF Delivery C. W. Bill Young (Bay Pines) VAHCS 10000 Bay Pines Blvd, Bay Pines, Florida 33744,
From Sources Sought posted on Apr 20, 2026Notice history
1-
Sources Sought LATEST Posted Apr 20, 2026
Details
Award Information
Contacts
Contracting Officer
Phone
Agency
Place of Performance
10000 Bay Pines Blvd
Bay Pines, Florida 33744
USA