66--ENVIRONMENTAL CHAMBER 140R8125Q0351
Summary
AI-generated · Sep 28, 2025For market research purposes, the agency seeks one environmental chamber to perform routine testing of concrete, aggregate, soil, and rock. Maintenance should be doable by local facility staff without complex or proprietary training or tooling. A firm fixed price purchase order is planned with delivery within 26 weeks after award, and a solicitation is expected to be posted around October 9, 2025; responses to this notice are not quotes or offers and no information costs will be reimbursed.
Amendment 01 adds draft specifications with a name-brand or equal requirement, currently identified as Russells Elite GD-83-3-AC (CLIN 00010). The unit must be indoor, reach-in freestanding, 75–85 cubic feet (2,124–2,405 L) of internal volume, internal dimensions 48 x 48 x 48 inches, temperature range -30 C (or lower) to 180 C, humidity 10%–95% RH, and load capacity at least 450 lbs with two shelves. It must use 480V power, UL 508A control panel, stainless steel interior liner, no exposed heating elements, forced air convection, a digital controller with Celsius/Fahrenheit display, a dedicated main power disconnect, a touch-screen controller with Windows OS, a dry air purge system at 10 CFM, a 6 kW boost heater, and a minimum one-year manufacturer’s warranty.
THIS IS A PRESOLICITATION NOTICE ONLY The Bureau of Reclamation, requires one (1) environmental chamber to perform routine concrete, aggregate, soil, and rock testing. Typical maintenance shall not require complex, costly, or proprietary training or tooling, allowing local facility maintenance staff to perform upkeep. This Pre-solicitation Notice is issued solely for informational, market research, and planning purposes only. It does not constitute a Request for Quote (RFQ) or a promise to issue an RFQ in the future. This Pre-solicitation Notice does not commit the Government to contract for any supply or service whatsoever. The Bureau of Reclamation is not seeking quotes at this time and will not accept unsolicited quotes. Respondents are advised that the United States (U.S) Government will not pay for any information or administrative cost incurred in response to this Pre-solicitation Notice. All costs associated with responding to this Pre-solicitation Notice will be solely at the responding party's expense. Responses to the Pre-solicitation Notice will not be returned. Please be advised that all submissions become Government property and will not be returned. Not responding to this Pre-solicitation Notice does not preclude participation in any future RFQ, if any is issued. Responses to this notice are not offers and cannot be accepted by the U.S Government to form a binding contract. It is the responsibility of the interested parties to continue to monitor the Beta Sam Opportunities (www.betasam.gov) site. The Bureau of Reclamation, Service Office, Denver, Colorado plans to award a Firm Fixed Price purchase order with a delivery within twenty-six (26 ) weeks from the date of award.. This Pre-solicitation Notice seeks to provide information to interested parties about potential opportunity. This office plans to post a solicitation on or about October 9, 2025.
From Presolicitation posted on Sep 22, 2025ENVIRONMENTAL CHAMBER- Amendment 01- Draft specifications Specifications This requirement is Name Brand or Equal- Russells Elite- GD-83-3-AC- CLIN 00010: One (1) EA- Environmental Chamber Requirements: a. Suitable for indoor use b. Reach-in freestanding unit c. Internal workspace (volume within cabinet): Minimum: 75 cu. ft. (2,124 liters) Maximum: 85 cu. ft. (2,405 liters) d. Minimum internal dimensions: 48 x 48 x 48 e. Temperature range: Low: -30 C (-22 F) or lower High: 180 C (356 F) or higher f. Humidity: 10% to 95% RH g. Load capacity: Shelves: 75 pounds per shelf minimum Total: 450 pounds minimum h. Include two (2) internal shelves i. Utilize 480V power j. UL 508A compliant control panel k. Stainless steel interior liner l. No exposed heating elements m. Forced air convection n. Digital controller capable of displaying temperature in C or F to the nearest 1 degree o. Dedicated Main Power Disconnect Switch p. User manual Touch screen controller with Windows OS Dry Air Purge system capable of 10 cfm 6 kW boost heater Minimum 1-year manufacturer s warranty
From Special Notice posted on Sep 26, 2025ENVIRONMENTAL CHAMBER
From Solicitation posted on Dec 10, 2025ENVIRONMENTAL CHAMBER
From Award Notice posted on Jan 28, 2026Notice history
4-
-
Special Notice Posted Sep 26, 2025View changes (2)
- Description: Description was updated
- Notice Type: Presolicitation → Special Notice
-
Solicitation Posted Dec 10, 2025View changes (5)
- Title: 66--ENVIRONMENTAL CHAMBER → ENVIRONMENTAL CHAMBER
- Description: Description was updated
- Notice Type: Special Notice → Solicitation
- Response Deadline: Sep 29, 2025 → Dec 17, 2025
- Set-Aside: None → Total Small Business Set-Aside (FAR 19.5)
-
Award Notice LATEST Posted Jan 28, 2026
Details
Award Information
Award Notices
Awardees
| Company Name | UEI | CAGE Code | Location |
|---|---|---|---|
| RUSSELLS TECHNICAL PRODUCTS INC | GENCJ3JK7NS1 | 60210 | Holland, MI |
Contacts
Phone