Contacts, documents and full notice history are available with a subscription.
Special Notice Expired 1 notice 1 document

6515--Intent to Sole Source 36C25925Q0611

Solicitation 36C25925Q0611 Copied Notice ID 90e872d905c3417c9490e5cff67104a9 Copied VETERANS AFFAIRS, DEPARTMENT OF — NETWORK CONTRACT OFFICE 19 (36C259)
SAM.gov
Posted
Jul 14, 2025
Deadline
Jul 21, 2025
Set-aside
None
NAICS
334516
PSC
6515

Summary

AI-generated · Aug 27, 2025

Procure a Finapres NOVA Plus NC System (Basic) from ADInstruments to support a VA-funded exercise trial in HFpEF. The package includes the NANO CORE double finger cuff system with finger cuffs in small/medium/large sizes, a Height Correction Unit, an upper-arm calibration module (sizes S/M/L), an analog input-output module (2 in/8 out), and a user manual. The system must deliver continuous non-invasive brachial and finger blood pressure with beat-to-beat hemodynamic parameters, 24/7 monitoring, and heart-rate/interbeat-interval data, using a Windows 10-based architecture to generate systolic, mean, diastolic pressures, BP curves, and related metrics.

A standout capability is uninterrupted monitoring during exercise on a stationary bike, enabled by the Height Correction Unit so arm movement does not disrupt data collection. The Finapres NOVA Plus is highlighted as the sole finger cuff option capable of estimating cardiac output, stroke volume, cardiac contractility, left ventricular ejection time, and total peripheral resistance non-invasively. The purchase is fixed-price, one-time, with a six-month period of performance from award, shipping to Salt Lake City VA Medical Center, and no security accreditation package required. This is an intent to sole-source procurement, with upgrades to be provided as specified in the corresponding quote.

STATEMENT OF NEED Contracting Officer: Jacqueline O Bryan VA Name: George E. Wahlen VAMC VA Address: 500 S Foothill Dr., SLC, UT 84148 E-Mail Address: Jacqueline.Obryan@va.gov Vendor Name: ADInstruments Contract Title: NOVA Plus NC System (Basic) Background: Currently, the VA utilizes arm blood pressure cuffs that use sphygmomanometry or automated oscillometry. These devices require that the patient remains completely still during the measurements and provides a single blood pressure value that requires 30-45 seconds per assessment. The Finapres NOVA is a clinical grade, non-invasive, continuous blood pressure monitor for accurate measurement of blood pressure that is determined with every heartbeat. Using proprietary technology, this device also estimates physiologic parameters such as: cardiac output, stroke volume, cardiac contractility, left ventricular ejection time, and total peripheral resistance. Traditional blood pressure cuffs do not provide this information, which are otherwise only available using costly, invasive hemodynamic monitoring. This equipment will be used to support Walter Wray s VA funded project E3343-R titled Efficacy of exercise training in patients with HFpEF . The proprietary finger cuff monitoring system will make it so that accurate measurements of blood pressure and the additional parameters outlined above can be determined during physical activity, ensuring patient safety. Scope: NANO CORE module (double finger cuff system) 3 finger cuffs (small, medium, large) Height Correction Unit (HCU) Upper arm module for brachial calibration with upper arm cuffs (small, medium, large) Analog Input- Output module (2 in 8 out) User Manual The vendor is to supply the needed system and upgrade as outlined and defined by the quote provided: Additional Information/Requirements: Features & Parameters Continuous non-invasive brachial and finger blood pressure No arm movement restrictions thanks to the HCU Beat-to-beat basic hemodynamic parameters 24/7 continuous patient-friendly monitoring System architecture based on Windows 10 Systolic, mean and diastolic pressure Blood pressure curves Heart rate and interbeat interval Unique Characteristics During clinical trials, the veteran will be monitored while riding a stationary bike. Traditional arm cuffs require the veteran to remain still during monitoring. However, the finger cuff can monitor cardiac variability at a continuous rate while the veteran is riding the stationary bike. This benefit allows for more accurate results. The Finepres NOVA Plus is the only finger cuff monitor that can estimate physiological parameters such as cardiac output, stroke volume, cardiac contractility, left ventricular ejection time, and total peripheral resistance. This system increases the cardiac variability in a non-invasive manner. Contract Type: Fixed price, one time buy. Period of Performance: From the date of award for six months. Place of Performance: Ship to: SLC VAMC 500 S Foothill Dr. #151 WHSE 7/ Research/ Liz Weld Salt Lake City, UT 84148 Security Requirements: The C&A requirements do not apply, and a Security Accreditation Package is not required.

From Special Notice posted on Jul 14, 2025

Notice history

1
  1. Special Notice LATEST Posted Jul 14, 2025

Details

Solicitation number 36C25925Q0611
Notice ID 90e872d905c3417c9490e5cff67104a9
Notice type Special Notice
Product / Service (PSC) 6515
NAICS 334516
Archive date Aug 20, 2025

Award Information

Awardees
0

Documents

1
View on SAM.gov

Contacts

primary
Jacqueline O'Bryan (CO)

Contract Officer

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
NETWORK CONTRACT OFFICE 19 (36C259)

Place of Performance

Dates

Posted Jul 14, 2025 1 year ago
Last Updated Aug 06, 2026 2 days ago
Due Jul 21, 2025 1 year ago