Contacts, documents and full notice history are available with a subscription.
Award Notice 3 notices 1 document

3540--766-26-1-401-0004 -Charleston CMOP Induction Sealer 36C77026Q0040

Solicitation 36C77026Q0040 Copied Notice ID 53303b8f67114c9ca324b510eba31b96 Copied VETERANS AFFAIRS, DEPARTMENT OF — NATIONAL CMOP OFFICE (36C770)
SAM.gov
Posted
Nov 03, 2025
Deadline
Nov 07, 2025
Set-aside
None
NAICS
333993
PSC
3540

Summary

AI-generated · Nov 04, 2025

Induction sealer for Charleston CMOP required to apply a tamper-evident seal to automated bottle handling in the Controlled Substances portion of the APFS, improving patient safety and confidence in packaging integrity.

One inline bottle induction sealer, either freestanding or with a stand, designed to integrate with existing conveyors and powered by 120 VAC or 208–240 VAC, with minimal assembly. Configuration can be performed by vendor or CMOP personnel. Throughput must meet at least 150 bottles per minute with approximately 6-inch bottle spacing, and handle 120 cc or 250 cc bottles with a 43 mm child-resistant cap. Features include remote start/stop via conveyor control, jam detection, and status indicators; a freestanding unit or stand-adaptable for placement over the conveyor; adjustable for 120 cc or 250 cc bottles (not necessarily both simultaneously). Positive factors include foil detection, crooked-cap detection, and stalled-backup detection. Delivery and installation timeline specifies delivery-ready equipment within 60 days of award, with installation potentially completed within 10 business days if included in the quote. VA will provide loading dock, engineering support for minor assembly and configuration, escorts, and required electrical power. Offerors must be manufacturers or authorized distributors, equipment must meet the stated specifications, and on-site work must be performed by qualified personnel, in compliance with applicable safety regulations. This is a sources-sought market-research notice; responses should address capability to meet the requirements and include company points of contact, SAM Unique ID, and a capability statement; responding does not guarantee a solicitation.

PURPOSE: This is a Sources Sought announcement only. This is not a solicitation announcement. The NCO 15 Consolidated Mail Outpatient Pharmacy(CMOP), Contracting office is conducting market research only to gain knowledge of potential qualified sources and is issuing this sources sought notice for induction sealer. Offers are not being solicited at this time. The Government does not intend to award a contract on the basis of this request for information. Vendors are required to address the following questions to be considered a viable source for future needs; Can you meet the requirement as described in attached the Statement of Requirements? Any responses to this sources sought must include an answer to all of the above question in order to adequately assess the capabilities of the marketplace in relation to the requirements of this procurement. When responding please include; Your company s POCs: Name Phone Number Email Address Your Company s SAM Unique ID Number Your Company s Capability Statement Interested sources may respond to this notice via email to kayla.powers@va.gov , on or before November 7th, 2025 @ 10:00 am CDT. This Request for Information does not obligate VA to the release of a solicitation. STATEMENT OF REQUIREMENTS DEPARTMENT OF VETERANS AFFAIRS CONSOLIDATED MAIL OUTPATIENT PHARMACY (CMOP) CHARLESTON INDUCTION SEALER BACKGROUND: Charleston CMOP located at 4136 Carolina Commerce Parkway, North Charleston, SC 29456 requires automated bottle sealing capability for the Controlled Substances portion of the Automated Pharmacy Fulfillment System (APFS) to meet increased patient safety for Veteran patients. An important part of this equipment is maintaining consistency and improving patient confidence in the integrity of their medication packaging. Medication bottles that are sent via the mail stream are handled by many people, and providing a tamper evident seal on these bottles provides better patient safety and improved patient confidence that their prescription is intact and proper. STATION INFORMATION: ONSITE REQUIREMENTS: There is no on-site requirement for this equipment purchase SITE SPECIFIC DATA: All dimensions, measurements, existing equipment, and site conditions represented herein are for estimating purposes only. Vendor shall verify all site-specific data prior to offering a proposal. SERVICES: The vendor shall provide one (1) inline bottle induction sealer shall be free standing or equipped with an optional stand that provides adjustment to work with existing conveyor equipment. The sealer shall be powered by either 120VAC or 208VAC. The sealer shall require minimal assembly that can be completed by a technician with minimal experience. Configuration shall be completed by vendor personnel, or it should be able to be performed by CMOP personnel without extensive training. Other requirements include: Power: 120VAC with NEMA 5-15 plug and minimum 5 ft cord, or 200-240VAC with NEMA 5-15 plug and minimum 5 ft cord. Throughput: Sealer shall be able to accept either 120cc or 250cc bottles with approximately 43mm diameter Child Resistant Cap (CRC). The minimum system capacity should be 150 bottles per minute with an anticipated 6in spacing between bottles. Features: Sealer shall have the ability to be remotely started/stopped via input from the conveyor control logic. Sealer shall have jam detect to prevent melting bottles that become jammed/stopped in the sealer. Light indicators that identify running condition, faults, and other important states Free standing (or with a stand accessory) that allows the unit to be placed over existing conveyor. The stand/sealer shall be adjustable to work with both 120cc or 2500cc bottles. It does not have to do both types simultaneously, but that would be considered a positive factor. Additional features not required but considered a positive factor are foil detection, crooked cap detection, and stalled bottle/bottle back-up detection. Installation: Unit shall be delivered and ready for installation and configuration within 60 days of award. All manuals and instructions for installation and configuration shall be delivered prior to or at unit delivery. If the vendor chooses to provide installation as part of the equipment cost, then installation shall take place within 10 business days of unit delivery. VA Responsibilities: VA will provide: Loading dock for the offload of equipment. Engineering staff to provide minor assembly, installation, and basic configuration. Escorts for vendor staff for any on-site portion of the installation. Electrical power meeting the specifications of the equipment provided. General Requirements: WORKMANSHIP: All work will be performed by trained, qualified technicians in accordance with the manufacturer s recommendations and all applicable Federal, State, local and VA regulations. All items for consideration shall conform to current regulations, codes and standards, to include but not limited to, OSHA, USP, NIOSH, local/state and federal codes, National Medical Device Amendments of 1976, and Safe Medical Device Amendments of 1998. PERIOD OF SERVICE: The term of this contract is for the procurement of the induction sealer, installation if provided, and the warranty period of the equipment. QUALIFICATION OF OFFERORS: Offerors must be manufacturers or authorized distributors for the products offered. Equipment must meet the specifications listed. Any vendor personnel performing work on-site must be qualified and knowledgeable on the equipment proposed. SAFETY REQUIREMENTS: In the performance of this contract, the contractor shall comply with all federal, state, VA and local safety regulations. The Contracting Officer or his designee will notify the contractor of any noncompliance with the foregoing provisions and action to be taken. After receipt of such notice, the contractor shall immediately correct the conditions to which attention has been directed. Such notice, when served on the contractor, his representative at the site of the work, shall be deemed sufficient for this purpose. All electrical work shall conform to NFPA 70, 70B and 70E standards. SECURITY REQUIREMENTS: The C&A requirements do not apply, and that a Security Accreditation Package is not required. STANDARDS OF CONDUCT: IAW VA Policy, when on site, vendors must comply with VA standards of conduct. The on-site Contracting Officer s Representative shall refer to the Contractor for immediate action (including, but not limited to, removal from the work site) any contract technician whose personal or professional conduct jeopardizes or interferes with the regular and ordinary operation of the CMOP facility. Breaches of conduct include, but are not limited to, intoxication or debilitation resulting from drug use; theft; dereliction; negligence in performing tasks or other conduct resulting in complaints by staff or management.

From Sources Sought posted on Nov 03, 2025

See attached

From Solicitation posted on Dec 02, 2025

Notice history

3
  1. Sources Sought Posted Nov 03, 2025
  2. Solicitation Posted Dec 02, 2025
    • Description: Description was updated
    • Notice Type: Sources SoughtSolicitation
    • Response Deadline: Nov 07, 2025Dec 12, 2025
    • Set-Aside: NoneTotal Small Business Set-Aside (FAR 19.5)
  3. Award Notice LATEST Posted Mar 10, 2026

Details

Solicitation number 36C77026Q0040
Notice ID 53303b8f67114c9ca324b510eba31b96
Award number 36C77026P0037
Notice type Sources Sought
Product / Service (PSC) 3540
NAICS 333993
Place of performance LADSON, SC
Archive date Jan 06, 2026

Award Information

Awardee
1
Total Awarded
$15,973.00
Award Date
Feb 26, 2026

Awardees

Company Name UEI CAGE Code Location
LALANDERS LLC L1M7QGN9B1C5 9VCZ5 FREDERICK

Documents

1
View on SAM.gov

Contacts

primary
Kayla Powers

Contracting Specialist

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
NATIONAL CMOP OFFICE (36C770)

Place of Performance

Department of Veterans Affairs Charleston CMOP 766A
4136 CAROLINA COMMERCE PKWY
LADSON, SC 29456

Dates

Posted Nov 03, 2025 9 months ago
Last Updated Aug 06, 2026 2 days ago
Due Nov 07, 2025 9 months ago