Z1DA--Improve CLC and Facility Security 539-25-506 36C25025Q0554

Solicitation 36C25025Q0554 Copied Notice ID 57d7f071bf324bb496e7fa0ce6d6f8c3 Copied VETERANS AFFAIRS, DEPARTMENT OF — 250-NETWORK CONTRACT OFFICE 10 (36C250)
SAM.gov
Posted
Jul 07, 2025
Deadline
Jul 14, 2025
Set-aside
None
NAICS
238210
PSC
Z1DA

Summary

AI-generated · Aug 23, 2025

Provide complete construction services to install additional security cameras at the Cincinnati VAMC, covering Building 2 (CLC) and Building 1, including all labor, materials, equipment, and supervision needed for installation and integration with the facility network.

Updated guidance specifies CAT6A Ethernet (Power over Ethernet) cabling for all new cameras, with these routing details: the camera in A731A runs only to A731; the six cameras on Building 2, Floor 1 (CLC) run to the 1144 teledata closet; the camera in A728D runs to the B505G teledata closet; and the camera outside C3024 runs to the C176 current / C1022 future teledata location in the primary care construction area. All camera feeds (except the A731A path) tie back to the Police Watch Office switch. The SOW still requires 12x4 basket-type cable trays. Additionally, a separate SSHO, and proof of BICSI certification (Certified Installer Level 1/2 or Technician) are required.

The chosen contractor shall provide complete construction services for labor, materials, equipment, and supervision required to complete the Improved CLC & Facility Security project for the Cincinnati VAMC, Cincinnati Campus. This project will install additional security cameras in building 2, the CLC, as well as building no. 1 at the Cincinnati VAMC.

From Solicitation posted on Jun 03, 2025

Q&A Q: Spec section 01 35 26 states the SSHO needs to be separate from the superintendent. Can this be change to where the superintendent can act as the SSHO. A separate SSHO will add considerable cost to the project. A: I need both superintendent and a SSHO. Q: Will a BICSI RCDD and BICSI certifies installers be required for this project? A: 28 05 00 8 The Contractor shall provide proof project superintendent with BICSI Certified Commercial Installer Level 1, Level 2, or Technician to provide oversight of the project. Q: The SOW 3.1.c.iii states to use 12 x 4 basket type cable tray for communication cables in corridors. Can we get updated drawings of where the cable trays are? The SOW 4.1.a states that all new cameras must be tied into either directly or via an adjacent fiber patch panel in a nearby teledata closet. All new cameras will have to run fiber back to the switch in the Police Watch Office. Are these cameras to be installed with the use of fiber optic cable and not Cat 6 copper cable? Can you call out which cameras can go to which teledata closets and which need to be run all the way to the Police Watch Office? A: 3.1 Contractor to verify. 1 Yes, we want these using Fiber Optic Cable. 2 All cameras will need to run to the police watch office besides the camera in A731A. This feed will only run to A731.

From Solicitation posted on Jul 02, 2025

Page 2 of 2 Q: The SOW 3.1.c.iii states to use 12 x 4 basket type cable tray for communication cables in corridors. Can we get updated drawings of where the cable trays are? The SOW 4.1.a states that all new cameras must be tied into either directly or via an adjacent fiber patch panel in a nearby teledata closet. All new cameras will have to run fiber back to the switch in the Police Watch Office. Are these cameras to be installed with the use of fiber optic cable and not Cat 6 copper cable? Can you call out which cameras can go to which teledata closets and which need to be run all the way to the Police Watch Office? UPDATED ANSWER: 3.1 Contractor to verify. 1 We want these using standard CAT6A power over ethernet. 2 The camera in A731A will only run to A731. The 6 cameras in the (CLC) building 2 floor 1 will all run to 1144 teledata closet. The camera in A728D will run to B505G teledata closet. The camera in the hallway directly out side of C3024 will run to (C176 Current / C1022 Future)(same location) in the primary care construction area.

From Solicitation posted on Jul 07, 2025

Notice history

3
  1. Solicitation Posted Jun 03, 2025 View
  2. Solicitation Posted Jul 02, 2025
    • Description: Description was updated
    • Response Deadline: Jul 07, 2025Jul 14, 2025
  3. Solicitation LATEST Posted Jul 07, 2025
    • Description: Description was updated

Details

Solicitation number 36C25025Q0554
Notice ID 57d7f071bf324bb496e7fa0ce6d6f8c3
Notice type Solicitation
Product / Service (PSC) Z1DA
NAICS 238210
Archive date Aug 13, 2025

Award Information

Awardees
0

Contacts

primary
Stacie I Hill

Contract Specialist

Email

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
250-NETWORK CONTRACT OFFICE 10 (36C250)

Place of Performance

Dates

Posted Jul 07, 2025 1 year ago
Last Updated Aug 06, 2026 1 day ago
Due Jul 14, 2025 1 year ago