Contacts, documents and full notice history are available with a subscription.
Solicitation SBA Expired 2 notices 19 documents

XTLF 15-1018 Repair AA and E Storage at F527 FA3029-25-R-0007

Solicitation FA3029-25-R-0007 Copied Notice ID ff93bba946fc48e498ef4ca05fcb4a28 Copied DEPT OF DEFENSE — FA3029 71 FTW CVC
SAM.gov
Posted
Jul 29, 2025
Deadline
Aug 15, 2025
Set-aside
SBA
NAICS
236220
PSC
Z2JZ

Summary

AI-generated · Aug 24, 2025

Renovate Building 527’s AA&E storage room to meet UFC 04-026-01 and MIL-HNDBK 1013/1A, addressing the VANCE AFB 97-01 deviation. Work includes reinforcing the storage area by adding steel and plywood to surrounding interior walls and ceilings, removing and reinstalling existing fixtures on the new wall/ceiling faces, replacing the entry door with a compliant door, and substituting tamper-resistant fasteners for window fasteners. Interior electrical circuits dedicated to other areas will be moved to a new panel outside the room to improve access for emergency personnel. AA&E Risk Categories II–IV must be stored in a structure with at least 10 minutes of forced-entry resistance against threat severity level III.

Record 1 adds funding contingencies and award conditions: funds are not yet available, a bid guarantee will be required before award, and the government may cancel the solicitation with no reimbursement of offeror costs. Record 2 describes the same scope and requirements but does not include funding, bid guarantee, or cancellation provisions.

Notice to Offeror(s) and Supplier(s): Funds are not presently available for this effort. No award will be made under this solicitation until funds are available. Once funds are available, bid guarantee will be required before award. The Government reserves the right to cancel this solicitation, either before or after the closing date for receipt of proposals. In the event the Government cancels this solicitation, the Government has no obligation to reimburse an offeror for any cost. The purpose of this solicitation is to notify prospective contractors on the performance of construction services for project XTLF 15-1018 Repair AA and E Storage at F527. This service will renovate building 527 to comply with UFC 04-026-01 and MIL-HNDBK 1013/1A. The building requires minor renovations to eliminate deviation request VANCE AFB 97-01. These renovations include the reinforcement of the existing AA and E storage room by adding steel and plywood layers to surrounding interior walls and ceiling. In addition, existing fixtures will be removed and reinstalled on the new wall and ceiling faces, the entry door will be replaced with a compliant door, and window fasteners will be replaced with compliant tamper-resistant fasteners. Circuits on the interior electrical panel dedicated to other areas of the facility will be relocated to a new panel outside the room, providing better access to emergency personnel. AA and E Risk Categories II through IV must be stored in a structure with a minimum forced entry resistance of 10 minutes against threat severity level III.

From Solicitation posted on Jul 02, 2025

The purpose of this solicitation is to notify prospective contractors on the performance of construction services for project XTLF 15-1018 Repair AA and E Storage at F527. This service will renovate building 527 to comply with UFC 04-026-01 and MIL-HNDBK 1013/1A. The building requires minor renovations to eliminate deviation request VANCE AFB 97-01. These renovations include the reinforcement of the existing AA and E storage room by adding steel and plywood layers to surrounding interior walls and ceiling. In addition, existing fixtures will be removed and reinstalled on the new wall and ceiling faces, the entry door will be replaced with a compliant door, and window fasteners will be replaced with compliant tamper-resistant fasteners. Circuits on the interior electrical panel dedicated to other areas of the facility will be relocated to a new panel outside the room, providing better access to emergency personnel. AA and E Risk Categories II through IV must be stored in a structure with a minimum forced entry resistance of 10 minutes against threat severity level III.

From Solicitation posted on Jul 29, 2025

Notice history

2
  1. Solicitation Posted Jul 02, 2025 View
  2. Solicitation LATEST Posted Jul 29, 2025
    • Title: XTLF 15-1018 Repair AA&E Storage at F527XTLF 15-1018 Repair AA and E Storage at F527
    • Description: Description was updated

Details

Solicitation number FA3029-25-R-0007
Notice ID ff93bba946fc48e498ef4ca05fcb4a28
Notice type Solicitation
Product / Service (PSC) Z2JZ
NAICS 236220
Place of performance Enid, Oklahoma
Archive date Jul 09, 2026

Award Information

Not yet awarded

Contacts

primary
Alexis Bishop

Email

Phone

secondary
Thomas Patton

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE AIR FORCE
AIR EDUCATION AND TRAINING COMMAND
FA3029 71 FTW CVC

Place of Performance

246 Brown Parkway Suite 225, Enid Oklahoma 73705
Enid, Oklahoma 73705
USA

Dates

Posted Jul 29, 2025 1 year ago
Last Updated Aug 06, 2026 2 days ago
Due Aug 15, 2025 11 months ago