Weapons Umbilical Reliability Test Set (WURTS) W50S8F25QA019
Summary
AI-generated · Aug 24, 2025Provide a stand-alone Weapons Umbilical Reliability Test Set (WURTS) to quickly assess end-to-end functionality of MIL-STD-1760 weapons umbilical cables and Joint Miniature Munition Interface (JMMI) cables, with a single cable test completed in 45–60 seconds from initiation. The unit must require no calibration and operate on standard, commercially available D-cell batteries, be portable (under 40 lbs), and housed in a weatherproof, rugged case with a closable lid to protect the umbilical interface and components.
It should deliver a quick, simple pass/fail indication (LED or display) and test each wire for continuity, open, and short circuits, including a self-contained diagnostic aid that identifies failures and maps them to the corresponding pin or wire. Compatibility must cover umbilicals from all current MIL-STD-1760 vendors, including Red Ring/FRCS and JMMI cables.
Looking for sources that can provide Weapons Umbilical Reliability Test Set (WURTS). The WURTS will be used as a stand-alone test set used to quickly assess the end-to-end functionality of MIL-STD-1760 weapons umbilical cables and Joint Miniature Munition Interface (JMMI) Cables. Description/Specifications 1 Testing Ability: MIL-STD-1760 and Joint Miniature Munition Interface Cables (JMMI). 2 Test Duration: Must complete a single cable test within 45-60 seconds from initiation. 3 Calibration: The test set must accurately test the required umbilicals without the need for calibration. 4 Operation: The test set must be stand-alone, powered by standard, commercially available D-Cell batteries. 5 Mobility: The test set must be portable and less than 40 lbs. 6 Protection: The test set must be in a weatherproof, rugged case with a closable lid to protect the umbilical interface and components from damage. 7 Testing Requirements: The item must assist an operator by allowing a quick and simple indication of the status of an umbilical of pass or fail, illuminated with either a LED or pass/fail display, and must test each wire for continuity, open, and short circuit conditions. A self-contained diagnostic aid will be included to allow failures to be identified or referenced to each pin or wire corresponding to the failure. 8 Compatibility: The item must be compatible with umbilicals from all current vendors producing MIL-STD-1760 including Red Ring /FRCS cables and JMMI cables.
From Sources Sought posted on Aug 19, 2025Notice history
1Details
Award Information
Not yet awarded
Contacts
Phone
Phone
Agency
Place of Performance
USA