J065--Aria/Eclipse Truebeam Maintenance John D. Dingell VA Medical Center 36C25026Q0007

Solicitation 36C25026Q0007 Copied Notice ID 7b5d6400c6f44fd98cc47d1e37ec3f2e Copied VETERANS AFFAIRS, DEPARTMENT OF — 250-NETWORK CONTRACT OFFICE 10 (36C250)
SAM.gov
Posted
Sep 24, 2025
Deadline
Oct 03, 2025
Set-aside
None
NAICS
811210
PSC
J065

Summary

AI-generated · Aug 24, 2025

Procure maintenance, preventive maintenance, and emergency repair services for Varian Aria/Eclipse Truebeam systems at the John D. Dingell VA Medical Center in Detroit, including two Truebeam linear accelerators, Eclipse calculation workstations, Aria workstations, and RGSC. The contractor shall provide all parts, labor, and technical phone support, perform a wellness check before the service plan begins, and supply everything needed to keep the equipment operating per OEM specifications and the government’s requirements. Work includes scheduled preventive maintenance, on-site repairs, and performance verification after every service event, with the equipment located at the VA facility.

Key requirements include unlimited on-site emergency repair with a four-hour response window, one-hour remote diagnostic capability, and same-day on-site arrival for calls placed before noon; eight hours to have necessary parts and supplies on site after an emergency call; and all required parts (new or reconditioned) supplied by the contractor. Maintenance cycles must follow OEM schedules, and the contractor must cover standard warranties (60 days for parts and repairs when installed by an FSE). The contractor must inspect for safety and calibration, provide on-site and remote support as needed, and escalate to a manufacturer senior engineer if problems persist or are repeating (more than five failures in one month). Responses from eligible businesses to participate in this market survey are requested with company and contact details and relevant certifications.

This Sources Sought/Market Survey Notice is being conducted by John D. Dingell VA Medical Center, 4646 John R. St., Detroit, MI 48201 to identify all sources that are capable of providing Varian Aria/Eclipse Truebeam Services for the period of February 19, 2026 February 18, 2027, at the discretion of the Government in strict accordance with all schedules, specifications, terms, conditions and provisions of any resulting contract. SCOPE OF WORK: The Contractor shall provide all parts, labor, application and technical phone support necessary to perform service and emergency repair on the Truebeam Linear accelerator SN: 193947 and 1911582, the Eclipse calculation workstations and the Aria workstations (HIT3652), and RGSC (HGSA0CU). The equipment is located at the John D. Dingell VA Medical Center (VAMC) 4646 John R Street Detroit, MI 48201, and is in strict accordance with all schedules, specifications, terms, conditions and provisions of this contract. The equipment shall be maintained for operation and performance. The contractor shall be required to perform a wellness check of the current products before the service plan begins. The contractor shall provide all parts, labor, and materials needed because of this wellness check PERFORMANCE REQUIREMENTS: The Contractor shall have all necessary supplies/parts, manuals and schematic drawings necessary to perform scheduled preventive maintenance service, emergency repair work and performance evaluation on the listed medical instrumentation. Contract shall include all normal spare parts, supplies necessary for repair and maintenance. Contractor shall have access and readily available manufacturer's replacement parts. Equipment placed under this service contract shall be in good operating condition. Preventive maintenance shall be done during normal working hours, Monday through Friday from 8:00 a.m. to 9:00 p.m., excluding federal holidays, unless arranged with Biomed or Radiation Oncology. Scheduled preventive maintenance cycles shall be completed within one working day; extensions beyond one working day require the approval of the Unit Supervisor and Chief, Biomedical Engineering department. Preventive maintenance schedule shall be according to OEM specifications. This schedule shall be provided before the contract begins. Unlimited emergency repair service shall be available on site, when necessary, Monday-Friday with a response time for emergencies within four (4) hours after the initial call placed by the COR or a delegate. The Contractor's service personnel shall respond within one (1) hour to telephone request or emergency service to determine the scope of the problem and make recommendations including scheduling for on-site repairs, should it be determined that on-site repairs are required. The Contractor shall arrive the same working day to start repairs when the initial call is made before noon. If the Contractor is initially contacted after 12 noon, then the Contractor shall make every effort to arrive during the same day, or no later than start of the next working day. Contractor shall supply remote diagnostic capability via telephone media. This service shall provide the ability to remotely diagnose current or potential equipment repairs, provide software workarounds, and assistance to the technologists operating the equipment. For each instrument system identified herein, the Contractor shall perform at a minimum those services as determined necessary by Biomedical Engineering and service supervisor. The using service specification on the listed medical instrument is based on: The equipment manufacturers recommended service and preventive maintenance procedures and schedules. The medical utilization of the instrument. Performance verification shall be required after every preventive maintenance and emergency repair event. This verification procedure may include performance testing for accuracy and precision of the instrument. If any procedures were performed that would in any way affect the calibration status of the instrument, the results of performance testing shall conform to established performance criteria for the instrument. Each maintenance or emergency repair event shall include inspection for internal and/or external causes of medical and electronic problems, including: Wear, misalignment, maladjustment, damage or other malfunctions with respect to the manufacturer specifications. Inspection for electrical safety and fire hazards. Cleaning and lubrication of equipment as required. Repair or replacement of all defective components necessary to conform to instrument specifications. Calibration or standardization of instruments required. Testing for proper operation of entire system and subsections. Document proper function and performance of instrument. Contractor shall have necessary equipment, parts and supplies on site within eight (8) hours after initial emergency service call is placed. For scheduled maintenance service, the Contractor shall have all necessary equipment, parts and supplies on site at the start of the service call. Any operating supplies necessary to perform service or repairs shall be provided by the Contractor at no cost to the Government. Should the Contractor need to use Government materials to effect emergency repairs, these materials shall be recorded to the field service report and replaced without cost within thirty (30) days from completion of the service call. Only new standard parts or reconditioned parts shall be furnished by the Contractor in effecting repairs. Parts supplied by the Contractor shall be installed by the Contractor. Parts that must be replaced for maintenance objectives and emergency repairs shall carry standard commercial warranties of sixty (60) days, if FSE installs. Likewise, the repair work itself shall carry at least sixty (60) day's warranty, if FSE does the work. All parts replaced within plan type coverage shall be identified by part number as shown on the schematics/parts list. Actual cost of parts shall be placed on service report but shall be billed as a no charge item on Contractor's invoice. All parts replaced, shall be new/exchange replacement parts, as suggested by the original manufacturer. If performance does not conform to the contract specification, the Government will require the Contractor to perform the service again in order to conform to contract specifications, at no increase in the contract cost. When the defects in service cannot be corrected by re-performance, the Government may: Require the Contractor to call in a certified technical expert on the listed instrument. Specifically require the Contractor to call in a senior technical engineer from the manufacturer. Repeated malfunctions of any systems component or subsection for more than five times within one month shall not be tolerated. The Contractor is responsible for repairing all faulty equipment and identifying the nature and cause if repeated failures. The Contractor in this situation shall either: Make repairs such that the identified problems are corrected to the extent that repeated failures are eliminated. Prove that the equipment is not faulty and that an external cause for the problem exists with recommendations for resolution. If this is a service your business can provide, respond to this Sources Sought by Tuesday, August 05, 2025; 3:00 P.M. Eastern time. Responses should include: (1) Business Name and Address (2) Point of Contact Name, Phone Number, and E-mail Address (3) SAM UEI and NAICS code (4) Business Size SMALL or LARGE (5) Type of Business SERVICE DISABLED VETERAN OWNED, VETERAN OWNED, 8A, HUBZone, WOMEN-OWNED etc. (6) Applicable GSA/FSS Contract Number (if applies). All businesses eligible to provide this service are encouraged to reply as this information may be used to determine potential set-asides for the above noted service. E-mail responses to: Alexis Alexander, at Alexis.Alexander1@va.gov. (Note: This is NOT A REQUEST FOR QUOTE or an announcement of a solicitation.)

From Sources Sought posted on Jul 25, 2025

SPECIAL NOTICE: Department of Veterans Affairs (VA), John D. Dingell VA Medical Center, 4646 John R. St., Detroit, Michigan, is soliciting and intends to award a firm fixed price contract for preventative maintenance and emergency repairs to Aria/Eclipse Truebeam Maintenance Agreement Services. NAICS Code 811210, size standard $34.0 million. The Government intends, in accordance with FAR 6.302.1 (only one responsible source and no other supplies or services will satisfy agency requirements), to negotiate on a sole source basis with Varian Medical Systems (3100 Hansen Way, Palo Alto, CA 94304), for this procurement due to the proprietary nature of the hardware, software, and firmware of this system. The Contractor shall provide all parts, labor, equipment, materials, supervision, necessary to service the Varian equipment located at the John D. Dingell VA Medical Center, 4646 John R. St., Detroit, Michigan, for the period of February 19, 2026 February 18, 2027 in strict accordance with the statement of work, all schedules, and terms and conditions of the resultant contract. No solicitation package is available. A determination not to compete is solely within the discretion of the Government. Any response to this notice must show clear and convincing evidence that competition would be advantageous to the Government. Responses must be received NLT 3:00 Eastern on 10/03/2025. All responses must be emailed to Alexis.Alexander1@va.gov.

From Special Notice posted on Sep 24, 2025

Notice history

2
  1. Sources Sought Posted Jul 25, 2025 View
  2. Special Notice LATEST Posted Sep 24, 2025
    • Title: Varian Aria/Eclipse Truebeam MaintenanceJ065--Aria/Eclipse Truebeam Maintenance John D. Dingell VA Medical Center
    • Description: Description was updated
    • Notice Type: Sources SoughtSpecial Notice
    • Response Deadline: Aug 05, 2025Oct 03, 2025
    • Set-Aside: No Set aside usedNone

Details

Solicitation number 36C25026Q0007
Notice ID 7b5d6400c6f44fd98cc47d1e37ec3f2e
Notice type Special Notice
Product / Service (PSC) J065
NAICS 811210
Archive date Dec 02, 2025

Award Information

Awardees
0

Documents

1
View on SAM.gov

Contacts

primary
Alexis S. Alexander

Contracting Officer

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
250-NETWORK CONTRACT OFFICE 10 (36C250)

Place of Performance

Dates

Posted Sep 24, 2025 10 months ago
Last Updated Aug 06, 2026 1 day ago
Due Oct 03, 2025 10 months ago