USCGC POLAR STAR WINDINGS EVALUATION 70Z08526Q003195

Solicitation 70Z08526Q003195 Copied Notice ID f119dcda0ed44087857bb872d3e0e8dc Copied HOMELAND SECURITY, DEPARTMENT OF — SFLC PROCUREMENT BRANCH 2(00085)
SAM.gov
Posted
Feb 19, 2026
Deadline
Feb 23, 2026
Set-aside
8AN
NAICS
336611
PSC
J020

Summary

AI-generated · Feb 20, 2026

Assess and document the condition of USCGC Polar Star’s #2 ship service generator (750 kW, 450 VAC, 720 RPM) via an on-site field inspection conducted with an OEM-certified technical representative and in the presence of designated USCG personnel. The visit must be coordinated with the specified points of contact, and power requirements must be provided in advance; USCG will supply power sources. Because of an overheated event that left visibly burnt field winding poles, initial and final operational tests are not advised. The contractor will perform an in-depth assessment to identify damage and repair options (including a generator groom) and must deliver a Condition Found Report detailing findings, recommended actions, part numbers/lead times if additional work is needed, and a trip report. The contractor must provide all instruments and equipment, observe safety protocols, and align with OEM standards and referenced guidance.

Place of performance includes USCGC Polar Star in Hobart, Australia, and USCGC Polar Sea in Benicia, CA, with a period of performance from 23 February to 20 March 2026. Security requires a valid government ID and Coast Guard escort; access will be coordinated through a CG sponsor. This is a sole-source, firm-fixed-price action to TECO Westinghouse under FAR Parts 12 and 13, with no solicitation available; responses may be considered only to determine if competition would be advantageous, and must be submitted in writing by the stated deadline.

NOTICE OF INTENT TO SOLE SOURCE 70Z08526Q003195 The Department of Homeland Security {DHS}, United States Coast Guard {USCG} Surface Forces Logistics Center {SFLC}, located at 1 Eagle Road Bldg. 55, Alameda CA 94501 is issuing this Notice of Intent {NOI} to inform industry contractors of the Government's intent to Award a Sole Source Firm Fixed Price {FFP} Contract IAW Federal Acquisition Regulation {FAR} Part 12 and 13 procedures. The intended Contractor TECO WESTINGHOUSE, 5100 N. IH35, Round Rock, TX, 78681 United States. USCG SFLC requires: USCGC POLAR STAR generator testing and assessment. This procurement is being conducted using commercial item procedures pursuant to Federal Acquisition Regulation {FAR} Part 12 and FAR Part 13, specifically FAR 13.106-1{b}{1}, allowing the Contracting Officer {KO} to solicit from one source. The North American Industry Classification System {NAICS} for this requirement is 336611 - Ship Building and Repairing. The Product of Service Code for this requirement is 2090. This will not be a small business under the Small Business Administration {SBA} size standard for this sector. This notice of intent is neither a formal solicitation nor a request for competitive proposals. No solicitation document is available, and telephone requests will not be honored. No award will be made on the basis of unsolicited quotations or offers received in response to this notice. Any response to this notice must show clear, compelling and convincing evidence that competition will be advantageous to the Government. The intent of this synopsis is for informational purposes only. Information received will normally be considered solely for the purpose of determining whether to conduct competitive procurement. A determination by the Government not to complete this action based on this notice is solely within the discretion of the Government. All inquiries and concerns must be addressed in writing via e-mail to Ms. Oneal at donna.j.oneal@uscg.mil with the following information referenced in the subject line, Solicitation 70Z08526Q003195. A determination by the Government not to complete this proposed procurement based on the responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct competitive procurement. All interested parties who are responsible, certified, and capable may identify their interest and may submit an offer or quotation which shall be considered by the agency no later than 8:00 AM Pacific Time {PST} on February 23, 2026, to Ms. Oneal at donna.j.oneal@uscg.mil The interested parties bear full responsibility to ensure complete transmiss TECHNICAL SERVICES USCGC POLAR STAR (WAGB-10) Z14501 ASSESSMENT OF #2 SHIP SERVICE GENERATOR Objective. The objective of this requirement is to conduct an inspection and assessment of the #2 ship service generator (750 KW, 450 VAC, 720 RPM) on USCGC Polar Star. References. USCG Technical Publication 4397A_311_B, SHIP SERVICE DIESEL GENERATOR (SSDG) GENERATOR USCG SFLC Standard Specification 3020, OVERHAUL AC ELECTRICAL MOTORS COMDTINST 9077.1 (series), Equipment Lockout/Tags-Plus Process American National Standards Institute (ANSI/EASA) AR100, 2015, Recommended Practice for the Repair of Rotating Electrical Apparatus Background. This requirement is for the contractor to conduct an in-depth inspection and assessment of the #2 ship service generator on USCGC Polar Star (WAGB-10) and USCGC Polar Sea (WAGB-11). Ship s crew identified visibly burnt field winding poles following an overheat condition due to failed components in saltwater cooling system. The ship s crew technical expertise and onboard equipment is insufficient to conduct a comprehensive damage assessment to identify required repairs. Tasks. The contractor shall provide labor services and technical expertise to assess #2 ship service generator, of which includes but may not be limited to: Coordinate field visit with provided points of contact for an Original Equipment Manufacturer (OEM) certified technical representative. Services must be conducted in the presence of designated USCG personnel. Specific location instructions will be provided once Contractor receives approval for services by a warranted Contracting Officer (KO). USCG personnel will operate all shipboard machinery and equipment. USCG personnel will secure and tag applicable equipment prior to the start of any work. Due to known equipment damage, an initial and final operational test of equipment is not advised and required. Observe safety precautions when working with electrical and electronic equipment. Failure to comply exposes personnel to the danger of electrical shock and personal injury. In accordance with applicable references listed in section 2 of this document, and according to OEM standards, the Contractor shall perform a groom for the ship service generator on USCGC Polar Star and USCGC Polar Sea. The assessment on USCGC Polar Star is to identify the full extent of damage to the equipment and recommended repair options. The assessment on USCGC Polar Sea is to identify the existing condition of the equipment to identify necessary shop work if used as a replacement unit on USCGC Polar Star. The Contractor must provide all instruments and equipment to perform inspection and evaluation. Prior to field visit, the Contractor must specify power requirements for all equipment to be used. USCG will coordinate providing power sources. Any additional material and labor (and associated costs) outside the scope of the field visit, or above the not to exceed price, must receive approval from a warranted Contracting Officer (KO) prior to proceeding. The Contractor shall submit a Condition Found Report. Provide an invoice and trip report including at least the following: service dates and location, issue description with any errors/symptoms, inspection and troubleshooting steps, findings, resolution, and recommendations (if any). If parts are needed for additional work, the contractor must provide part number, the quantity needed, price per unit, lead time, and potential source(s) with contact information. Government Furnished Property. None. Security Requirement. Government facility access is required. Contractor shall have a valid government issued ID (or driver s license) and show identification at the security gate. A Coast Guard representative from the cutter or Product Line will sponsor and escort vendor to the cutter. Place of Performance. The Contractor shall coordinate travel for services to the following locations: USCGC Polar Star: Hobart, Tasmania, Australia USCGC Polar Sea: Suisun Bay Reserve Fleet, 2595 Lake Herman Rd, Benicia, CA 94510 Period of Performance. 23-February to 20 March 2026 Points of Contact. USCG-SFLC-LREPL, Asset Manager: LT Mikael Axelsson, Mikael.J.Axelsson@uscg.mil, 571-607-1134 USCGC POLAR STAR, Engineer Officer: LCDR Joshua Herring, Joshua.C.Herring@uscg.mil Photos. Data nameplate for #2 ship service generator on USCGC Polar Star.

From Special Notice posted on Feb 19, 2026

Notice history

1
  1. Special Notice LATEST Posted Feb 19, 2026

Details

Solicitation number 70Z08526Q003195
Notice ID f119dcda0ed44087857bb872d3e0e8dc
Notice type Special Notice
Product / Service (PSC) J020
NAICS 336611
Set-aside 8(a) Sole Source
Place of performance Benicia, California
Archive date Mar 10, 2026

Award Information

Not yet awarded

Contacts

primary
DONNA O'NEAL

Email

Phone

secondary
ULISES BALMACEDA

Email

Phone

Agency

HOMELAND SECURITY, DEPARTMENT OF
US COAST GUARD
SFLC PROCUREMENT BRANCH 2(00085)

Place of Performance

Benicia, California 94510
USA

Dates

Posted Feb 19, 2026 5 months ago
Last Updated Aug 06, 2026 1 day ago