USCGC Penobscot Bay Water Mist Suppression System 70Z08526Q0000870-1
Summary
AI-generated · Dec 02, 2025Perform a 5-year and annual inspection of the Hi-Fog water mist fire suppression system on the USCGC Penobscot Bay (Bayonne, NJ). A HI-FOG certified technician must set up the system for testing, complete the water mist system test, and return the system to normal operation, ensuring all connections, fittings, and equipment within the system are functioning correctly. Use MPC guidance R-A-13380, R-M-13373, and R-C-14526 during the work. Replacement parts to be included in the inspection package include 30 hoses (36 inch, 8 mm for GPU UU1168), 1 hose assembly - N2 regulator (A20079.1), 2 water filters (R1 1/2, 60-micrometer, E31048), 1 low-pressure fresh water safety valve (M-0010165), 2 SVM20 DNV valve rebuild kits (V14020), and a Jockey Pump.
Discrepancies found during inspection shall be noted, and corrections made only if no additional cost is required. If correcting a discrepancy would incur costs beyond the quote, route the issue to the customer for approval before proceeding.
STATEMENT OF WORK CGC PENOBSCOT BAY OPFAC: 17507 LOCATION: Bayonne, NJ EQUIPMENT: Hi-Fog Water Mist Fire Suppression System COMPONENT AFFECTED: 5YR and ANNUAL INSPECTION OF SYSTEM/ Renewal of 29 Bottles and certified MPC: R-A-13380, R-M-13373, R-C-14526 Contractor must be HI-FOG certified Technician. Contractor must set up water mist system for testing; complete the water mist system test; and place water mist system back in normal operation once test is completed. Contractor must ensure all connections, fittings, and equipment within the water mist system are operating correctly as well. Contractor shall use MPC R-A-13380, R-M-13373, R-C-14526 as guidance. Replacement Parts to be included in 5-Year Annual Inspection: 30 - HOSE 36INCH 8MM FOR GPU (UU1168) 1 - HOSE ASSEMBLY - N2REGULATOR (A20079.1) 2 - FILTER WATER FILTER R1 1/2, 60-MICROMETER (E31048) 1 - LOW PRESSURE FRESH WATER SAFETYVALVES (M-0010165) 2 - SVM20 DNV VALVE REBUILD KITS (V14020), Jockey Pump Any discrepancies found shall be noted; and corrected only if no other cost is needed. If any discrepancy causes cost outside the quote, this shall be routed through customer before discrepancy is corrected. POP: 08DEC25-12DEC25 LOCATION/POC: Ricciardi, Vincent CWO-2 USCG CGC PENOBSCOT BAY (USA) Vincent.Ricciardi@uscg.mil Address: CGC Penobscot Bay (WTGB-107) 85 Port Terminal Blvd. Slip 2 Bayonne NJ. 07002 252-619-6669
From Combined Synopsis/Solicitation posted on Dec 01, 2025Notice history
1-
Combined Synopsis/Solicitation LATEST Posted Dec 01, 2025
Details
Award Information
Not yet awarded
Contacts
Phone
Phone
Agency
Place of Performance
USA