Contacts, documents and full notice history are available with a subscription.
Combined Synopsis/Solicitation SBA Expired 1 notice 11 documents

USCGC Patoka Generator Repair 70Z02925QNEWO0015

Solicitation 70Z02925QNEWO0015 Copied Notice ID 70b45f2299724e7d85dd15f161b62cad Copied HOMELAND SECURITY, DEPARTMENT OF — BASE NEW ORLEANS(00029)
SAM.gov
Posted
Sep 16, 2025
Deadline
Sep 24, 2025
Set-aside
SBA
NAICS
238210
PSC
Z2PZ

Summary

AI-generated · Sep 17, 2025

Replace and repair critical power equipment on USCGC Patoka: remove and replace the 600-amp switchgear; troubleshoot, repair, and service the 100 kW diesel generator and return it to fully mission capable status; and perform a generator load test to verify readiness. Ancillary work necessary to complete the project is included as part of the contract. A site visit is required, with full specifications, drawings, and site-visit details in the attached Statement of Work; work will be performed at the Patoka in Greenville, MS.

This is a firm-fixed-price construction contract awarded to the lowest-priced qualified quote, issued as a combined synopsis/solicitation for non-commercial items. Vendors must be SAM-registered, and all work and site access will be coordinated through the designated government point of contact per the RFQ. Submit quotes through the RFQ process and direct any questions through the RFQ channels as specified.

This is a combined synopsis/solicitation for non-commercial items prepared in accordance with the format in FAR Part 36, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and no other written solicitation will be issued. Instructions to offerors, (FAR Part 36) evaluation criteria, and all applicable FAR Provisions and Clauses are attached. The solicitation number is 70Z02925QNEWO0015 and is issued as a Request for Quotation (RFQ). The solicitation document and incorporated provisions and clauses. Federal Acquisition Regulation (FAR) Clauses and Department of Labor Wage Rates for Construction are included in this order and are applicable. Where Federal Acquisition Regulation clause language is inconsistent with FAR Part 36, Legal Effect of Quotations, that language is hereby tailored in accordance with FAR Part 36 to be consistent with a request for quotations. This tailoring includes but is not limited to the following: In accordance with FAR Part 36, a quotation is not an offer, and any clause provision to the contrary is hereby modified to be consistent with FAR Part 36. Where the word "offer/offeror" or a derivative of that word appears, it is changed to "quote/quoter" or a derivative of that word. This is a small business set aside, the applicable NAICS code is 238210 and PSC code is Z2PZ This solicitation will result in a Firm-Fixed Price Construction Contract awarded to the offeror with the Lowest Price. Offerors must actively be registered in System for Award Management - https://www.sam.gov The USCGC Patoka has a requirement for the vendor to provide all labor, materials, and equipment necessary to remove and replace the following: Contractor shall troubleshoot and repair the 600-amp switchgear. Contractor shall troubleshoot, repair, and service 100 kW diesel generator returning it to fully mission capable. Contractor shall perform a load test to ensure generator is fully mission capable. This summary is not all inclusive and delineates only the work items deemed as major to the contract. Ancillary work items necessary to attain the completed project shall be included in the contract as inherent to the work. Please see the attached Statement of Work for specifications of work, illustrations and POC s for setting up site visits. 30 DAY ARO FOB Destination to: USCGC Patoka 1797 Harbor Freight Road Greenville, MS 38701 FAR 52.237-1 - Site Visit. Offerors or quoters are urged and expected to inspect the site where services are to be performed and to satisfy themselves regarding all general and local conditions that may affect the cost of contract performance, to the extent that the information is reasonably obtainable. In no event shall failure to inspect the site constitute grounds for a claim after contract award. The Government Point of Contacts (POC) for this project is: MKC Jacob Newland Jaocb.m.newland@uscg.mil 662 394 9746 All work shall be coordinated through the POC. All quotes are due at by 5:00pm CST on September 24, 2025. Submit quotes to the following e-mail address: Wesley.k.hanna@uscg.mil, all questions regarding this solicitation shall be submitted to the Purchasing Agent at Wesley.k.hanna@uscg.mil no later than September 23, 2025, 5:00pm CST or the question may not be answered.

From Combined Synopsis/Solicitation posted on Sep 16, 2025

Notice history

1
  1. Combined Synopsis/Solicitation LATEST Posted Sep 16, 2025

Details

Solicitation number 70Z02925QNEWO0015
Notice ID 70b45f2299724e7d85dd15f161b62cad
Notice type Combined Synopsis/Solicitation
Product / Service (PSC) Z2PZ
NAICS 238210
Place of performance Greenville, Mississippi
Archive date Sep 25, 2025

Award Information

Not yet awarded

Contacts

primary
Wesley Hanna

Email

Phone

secondary
Joel Ivy

Email

Phone

Agency

HOMELAND SECURITY, DEPARTMENT OF
US COAST GUARD
BASE NEW ORLEANS(00029)

Place of Performance

Greenville, Mississippi 38701
USA

Dates

Posted Sep 16, 2025 10 months ago
Last Updated Aug 06, 2026 2 days ago