USCGC George Cobb Watertight doors and scuttles 70Z08526Q0023425
Summary
AI-generated · Mar 09, 2026Fabricate seven steel watertight doors and two scuttles for the USCGC George Cobb, built to the specified drawings (USCG DWG FL-1602-89; NAVSEA DWG 803-1401890 and 803-1401892). Doors are 26" x 66" and come in multiple swing configurations (right- or left-hand) with hasp and staple, and various fixed-light options or none, all in weather-tight construction per the drawings. Scuttles are two sizes (18" and 21" diameter) with specific locking provisions, coaming height of 12", and per-drawing features such as internal toggle pin lock for one and hasp & staple for the other.
All items must be new manufacture and fully compliant with the referenced drawings and specifications. Delivery must occur within 12 months of contract award, with tracking information provided to the government within 48 hours of each shipment, to the designated delivery address in San Pedro, CA.
SCOPE OF WORK U. S. COAST GUARD CUTTER GEORGE COBB NAVSEA Doors and Scuttles. SECTION 1 GENERAL INFORMATION 1.1 Scope of Work Provide seven doors (USCG DWG FL-1602-89) and two scuttles (NAVSEA DWG 803-1401890 and 803-1401892) in accordance with below description. Steel construction. Doors (Total Qty. 7) (1) x DOOR - 26" X 66" C.O ., WEAT, RH W/ HASP AND STAPLE, W/0 FIXED LIGHT, USCG DWG FL- 1602- 89 (1) x DOOR - 26" X 66" C.O ., WEAT, LH W/ HASP AND STAPLE, W/0 FIXED LIGHT, USCG DWG FL- 1602- 89 (1) x DOOR - 26" X 66" C.O ., WEAT, LH W/ HASP AND STAPLE, W/0 FIXED LIGHT, USCG DWG FL- 1602- 89 (1) x DOOR - 26" X 66" C.O., WEAT, RH W/ HASP AND STAPLE W/ 14" X 18" FIXED LIGHT, USCG DWG FL- 1602- 89 (1) x DOOR - 26" X 66" C.O., WEAT, LH W/ HASP AND STAPLE W/ 14" X 18" FIXED LIGHT, USCG DWG FL- 1602- 89 (1) x DOOR - 26" X 66" C.O., WEAT, LH W/ HASP AND STAPLE AND 9" DIA FIXED LIGHT, USCG DWG FL- 1602- 89 (1) x DOOR - 26" X 66" C.O., WEAT, RH W/ HASP AND STAPLE AND 9" DIA FIXED LIGHT, USCG DWG FL- 1602- 89 Scuttles (Total Qty. 2) (1) x 18" DIA C.O., RSD, QA, WT, W/ INTERNAL TOGGLE PIN LOCK, COAMING 12" HEIGHT (NAVSEA DWG 803-1401890) (1) x 21" DIA C.O., RSD, QA, WT. W/ HASP & STAPLE, COAMING 12" HEIGHT (NAVSEA DWG 803-1401892) 1.2 Contact for questions: 1.1.5.1 Any questions regarding scope of work must be directed to the Contracting Officer. All items shall be new manufacture and fully compliant with the referenced drawings and any specifications identified in the scope of work. 1.3 Required Delivery Date and Address Required supplies shall be delivered to the below address within 12 months of contract award and tracking info must be supplied to the Government representative listed below within 48 hours of each individual supply being shipped. ATTN: MKCS William Gentry USCGC GEORGE COBB (WLM-564) 1001 South Seaside Avenue San Pedro, CA 90731
From Combined Synopsis/Solicitation posted on Mar 08, 2026Notice history
1Details
Award Information
Not yet awarded
Contacts
Phone
Phone
Agency
Place of Performance
USA