Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System 1333ND26QNB680282
Summary
AI-generated · Jun 13, 2026Three high-precision rotation stages are required to align three gratings about the roll axis in a far-field grating neutron interferometer used to measure the projection of the pair correlation function G(Z). Gratings are silicon wafers (~1 µm line period, 100 mm diameter) with ~100 g mass each, and the interferometer pattern is obtained by translating one grating, so the entire alignment assembly must be as light as possible while enabling full 360-degree rotation with very high resolution.
The stages must provide a resolution better than 0.00005 degrees and a clear aperture to pass the beam unattenuated and accommodate required cabling, control hardware, and software. Grating separations along the beam range from 1 mm to 300 mm for two gratings, with the third up to 5 m, and vertical translation of the gratings is required; the roll stages that translate must each weigh under 1 kg. Procurement is for three units, including necessary control hardware and software.
The NIST neutron imaging team, in the Radiation Physics Division of the Physical Measurement Laboratory, is developing a far-field grating neutron interferometer to measure the projection of the pair correlation function, G(Z), of a sample of interest. This interferometer geometry requires precision alignment of 3 gratings about the roll direction of the neutron beam. Since G(Z) is a vector quantity, aligned perpendicular to the grating direction, the grating alignment stages need to be able to rotate a full 360, with high resolution. The gratings are lines etched into silicon wafers, where the period of the lines is of order 1 micrometer and the wafers are 100 mm in diameter. The mass of a grating, including a holder is of order 100 g. The interferometer pattern is measured by translating one of the gratings, so that that mass of the alignment system must be kept to as low as achievable. For control hardware, the separation of two of the gratings along the beam ranges from 1 mm to 300 mm. The third grating is separated by up to 5 m. The overall grating alignment system requires translating the gratings in the vertical direction, requiring that the grating roll stages (which much also translate) be less than 1 kg in mass. This procurement is to obtain quantity three high precision rotation stages (resolution better than 0.00005 degrees) with a clear aperture to allow the beam to pass unattenuated and required cabling, control hardware, and control software.
From Solicitation posted on Jun 12, 2026Notice history
1-
Solicitation LATEST Posted Jun 12, 2026
Details
Award Information
Not yet awarded
Contacts
Phone
Agency
Place of Performance
USA