Contacts, documents and full notice history are available with a subscription.
Combined Synopsis/Solicitation Due Soon 2 notices

Trailer W911S226U3970

Solicitation W911S226U3970 Copied Notice ID 3c3937a6f62c48e9abe0536dd59ab6ad Copied DEPT OF DEFENSE — W6QM MICC-FT DRUM
SAM.gov
Posted
Aug 07, 2026
Deadline
Aug 12, 2026
Set-aside
None
NAICS
336212
PSC
4210

Summary

AI-generated · Aug 06, 2026

Design, manufacture, and deliver one custom-built, heavy-duty Mobile Command Center trailer, 42 feet long by 8 feet wide, to serve as a multi-agency incident command post for FES, Police, Guards, and Garrison Command Staff during large-scale emergencies. Platform and exterior requirements include a heavy-duty 5th-wheel kingpin or gooseneck hitch, minimum two flat-floor slide-outs, a heavy-duty automatic hydraulic leveling system, a curbside motorized awning with wind-retraction sensor, a full exterior vinyl wrap with branding and reflective striping (graphics package to be approved post-award), plus a lighting package with multiple high-lumen LEDs and a full emergency warning light system.

Power, climate, and interior/tech features include a minimum 20 kW diesel generator with remote interior start, three 15,000 BTU HVAC units, and a heavy-duty shore power connection with a suitable cord (50A or 100A and length as needed). A rack-mounted UPS is required. Inside, the trailer must have two zones—Main Operations Area and secure Conference Area—separated by a sound-deadening door, six workstations (one for a Dispatch Console), heavy-duty desks and cabinetry, two large magnetic whiteboards, and a full-height server rack. It must be pre-wired for Government Furnished Equipment including Motorola and Harris radios with roof antenna bases and coax to all workstations, CAT6 ethernet drops to the server rack, and pre-wiring for Government-installed FirstNet routing equipment, plus one large touchscreen monitor in the Conference Area. No lavatory or kitchenette. Graphics package must be approved by the Government post-award.

Procurement: 42 ft. Mobile Command Center (MCC) TrailerSCOPE:The contractor shall design, manufacture, and deliver one (1) custom-built, heavy-duty Mobile Command Center (MCC) trailer. The MCC will serve as a multi-agency incident command post for FES, Police, Guards, and Garrison Command Staff during large-scale emergencies.PLATFORM AND EXTERIOR SPECIFICATIONS:Dimensions: Minimum 42 ft. Length x 8 ft. Width (nominal).Hitch Type: Heavy-duty 5th-Wheel Kingpin (or Gooseneck) configuration, matched to a GVWR appropriate for the fully loaded trailer.Slide-Outs: Minimum of two (2) flat-floor slide-outs to maximize interior operational space.Leveling System: Heavy-duty automatic hydraulic leveling system (minimum 4-point).Awning: One (1) heavy-duty motorized awning on the curbside, positioned to cover the exterior monitor, with an automatic wind-retraction sensor.Graphics: Full custom exterior vinyl wrap with Department of War / Garrison FES branding and reflective striping (graphics package to be approved by the Government post-award).Lighting:Minimum of two (2) high-lumen LED scene lights per side (8 total).Full emergency warning light package (Red/Blue LEDs) conforming to emergency vehicle standards.POWER AND CLIMATE CONTROL:Generator: Minimum 20kW Onan (or equivalent) commercial-grade diesel generator with remote interior start and custom fabricated fuel cell.Climate Control: Three (3) 15,000 BTU roof-mounted HVAC units with heat pumps/strips, ducted for even air distribution, capable of maintaining 70�F interior temperature in extreme high-heat environments (110�F+ ambient).Shore Power: Heavy-duty shore power connection (e.g., 50A or 100A as appropriate for load) with a minimum 50-foot heavy-duty male-end umbilical cord.Power Protection: Rack-mounted Uninterruptible Power Supply (UPS) sized to support the communications and server rack to prevent drop-outs during power transition.INTERIOR LAYOUT AND FINISHES:Zones: Trailer must be divided into a Main Operations Area and a secure Conference Area, separated by a sound-deadening door. No lavatory or kitchenette to be included.Workstations: Six (6) total dedicated workstations. One (1) workstation must be customized specifically for a Dispatch Console.Desks/Cabinetry: Heavy-duty, commercial-grade desks and overhead/under-desk aluminum or high-pressure laminate storage cabinetry for each workstation.Whiteboards: Two (2) large magnetic dry-erase whiteboards (one in the main area, one in the conference area).COMMUNICATIONS AND TECHNOLOGY:Server Rack: Minimum one (1) full-height or half-height 19 inch EIA equipment rack structurally mounted and cooled.Radio Prep: Pre-wired for Government Furnished Equipment (GFE) Motorola and Harris radios. Must include roof-mounted antenna bases and coaxial cable runs to all six (6) workstations.Network/Data: Trailer must be pre-wired with CAT6 ethernet drops at all workstations, routed back to the server rack, ready for Government-installed FirstNet routing equipment.Monitors:One (1) large touchscreen interactive monitor mounted in the Conference Area.

From Combined Synopsis/Solicitation posted on Aug 06, 2026

The purpose of this amendment is to attach the graphics requirements and provide additional specifications for the trailer height, UPS system, EIA equipment rack, roof-mounted antennas, and exterior monitor. Procurement: 42 ft. Mobile Command Center (MCC) TrailerSCOPE:The contractor shall design, manufacture, and deliver one (1) custom-built, heavy-duty Mobile Command Center (MCC) trailer. The MCC will serve as a multi-agency incident command post for FES, Police, Guards, and Garrison Command Staff during large-scale emergencies.PLATFORM AND EXTERIOR SPECIFICATIONS:Dimensions: Minimum 42 ft. Length x 8 ft. Width (nominal).Hitch Type: Heavy-duty 5th-Wheel Kingpin (or Gooseneck) configuration, matched to a GVWR appropriate for the fully loaded trailer.Slide-Outs: Minimum of two (2) flat-floor slide-outs to maximize interior operational space.Leveling System: Heavy-duty automatic hydraulic leveling system (minimum 4-point).Awning: One (1) heavy-duty motorized awning on the curbside, positioned to cover the exterior monitor, with an automatic wind-retraction sensor.Graphics: Full custom exterior vinyl wrap with Department of War / Garrison FES branding and reflective striping (graphics package to be approved by the Government post-award).Lighting:Minimum of two (2) high-lumen LED scene lights per side (8 total).Full emergency warning light package (Red/Blue LEDs) conforming to emergency vehicle standards.POWER AND CLIMATE CONTROL:Generator: Minimum 20kW Onan (or equivalent) commercial-grade diesel generator with remote interior start and custom fabricated fuel cell.Climate Control: Three (3) 15,000 BTU roof-mounted HVAC units with heat pumps/strips, ducted for even air distribution, capable of maintaining 70�F interior temperature in extreme high-heat environments (110�F+ ambient).Shore Power: Heavy-duty shore power connection (e.g., 50A or 100A as appropriate for load) with a minimum 50-foot heavy-duty male-end umbilical cord.Power Protection: Rack-mounted Uninterruptible Power Supply (UPS) sized to support the communications and server rack to prevent drop-outs during power transition.INTERIOR LAYOUT AND FINISHES:Zones: Trailer must be divided into a Main Operations Area and a secure Conference Area, separated by a sound-deadening door. No lavatory or kitchenette to be included.Workstations: Six (6) total dedicated workstations. One (1) workstation must be customized specifically for a Dispatch Console.Desks/Cabinetry: Heavy-duty, commercial-grade desks and overhead/under-desk aluminum or high-pressure laminate storage cabinetry for each workstation.Whiteboards: Two (2) large magnetic dry-erase whiteboards (one in the main area, one in the conference area).COMMUNICATIONS AND TECHNOLOGY:Server Rack: Minimum one (1) full-height or half-height 19 inch EIA equipment rack structurally mounted and cooled.Radio Prep: Pre-wired for Government Furnished Equipment (GFE) Motorola and Harris radios. Must include roof-mounted antenna bases and coaxial cable runs to all six (6) workstations.Network/Data: Trailer must be pre-wired with CAT6 ethernet drops at all workstations, routed back to the server rack, ready for Government-installed FirstNet routing equipment.Monitors:One (1) large touchscreen interactive monitor mounted in the Conference Area. Interior Height: Thetrailer must have a minimum interior height of 80 inches (6 ft. 8 inches). This ensuresadequate head clearance for personnel and allows for the installation of overhead LEDlighting, wire runways, and ducted HVAC systems without restricting movement. ExteriorHeight: The overall exterior height of the trailer must not exceed 12 feet 6 inches (150inches) in its stowed/transport configuration. This measurement must include all roofmountedequipment, such as low-profile HVAC units, stowed light towers, and antennas, toguarantee clearance under standard highway bridges and overpasses. Runtime: The UPSsystem must be capable of powering all critical communication and network routingequipment for a minimum of 30 minutes under a full operational load. This runtime isintended to act as a power bridge, allowing safe power transition between Shore Power andthe onboard generator, or enabling a graceful shutdown of critical systems during a powerfailure. Wattage/Capacity: The syFor tstem must support a minimum continuous load of3,000VA / 2,700 Watts. The vendor must supply a double-conversion online UPS to ensuresensitive radio and IT equipment receive clean, regulated power, isolated from voltagespikes or generator sags. Rack Units (RU): The equipment rack must provide a minimumof 16U of usable rack space to accommodate patch panels, network switches, routers, theUPS, and radio chassis, while leaving room for future expansion. Rack Depth: The rackmust have a minimum usable depth of 25 inches (front-to-back rail depth) to safely housedeeper server-style equipment and the UPS chassis. The rack must also feature front andrear adjustable mounting rails and robust rear cable-management brackets designed towithstand transit vibration. Antenna Bases: The trailer must be equipped with a minimumof 6 roof-mounted antenna bases (standard threaded NMO mounts). Installation Detail: Thebases must be spaced at least 3 feet apart to prevent RF interference. They must be prewiredto the internal EIA equipment rack using low-loss coaxial cable (such as LMR-400or equivalent) and must include solid copper grounding planes integrated into the roofstructure. Monitor Size: The exterior display must be a 49-inch to 55-inch high-brightness,daylight-readable (minimum 1000 nits), commercial-grade outdoor monitor. Mounting andHousing: The monitor must be permanently housed in a recessed, weatherproof, andlockable exterior compartment rather than a removable mount. The compartment mustfeature gas-shock-assisted doors, integrated LED compartment lighting, and a heavy-dutyarticulating pull-out mount that allows the monitor to be angled for group briefings. Allexterior graphics require Government approval prior to application.

From Combined Synopsis/Solicitation posted on Aug 07, 2026

Notice history

2
  1. Combined Synopsis/Solicitation Posted Aug 06, 2026 View
  2. Combined Synopsis/Solicitation LATEST Posted Aug 07, 2026
    • Description: Description was updated

Details

Solicitation number W911S226U3970
Notice ID 3c3937a6f62c48e9abe0536dd59ab6ad
Notice type Combined Synopsis/Solicitation
Product / Service (PSC) 4210
NAICS 336212
Archive date Aug 07, 2027

Award Information

Not yet awarded

Documents

No files available

View on SAM.gov

Contacts

primary
Andre Bishop

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE ARMY
AMC
ACC
MISSION INSTALLATION CONTRACTING COMMAND
419TH CSB
W6QM MICC-FT DRUM

Place of Performance

Fort Sill, OK
73503

Dates

Posted Aug 07, 2026 1 day ago
Last Updated Aug 07, 2026 8 hours ago
Due Aug 12, 2026 4 days from now