AI-generated · Aug 28, 2025Procure a stylus profilometer through a combined synopsis/solicitation issued as an RFQ for commercial items. This is the sole solicitation; quotes are requested and no separate written solicitation will be issued. The procurement uses streamlined, simplified acquisition procedures.
Competition is unrestricted (full and open). The notice does not indicate any brand-name restrictions, required site visits, or special certifications.
COMBINED SYNOPSIS/SOLICITATION 1333ND25QNB640339 Stylus Profilometer This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6 Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested, and a separate written solicitation document will not be issued. This solicitation is being issued under the authority of FAR Part 13 Simplified Acquisition Procedures. This solicitation is a Request for Quotations (RFQ) for a Stylus Profilometer. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisitions Circular (FAC) 2025-05, effective 8/7/2025. The associated North American Industrial Classification System (NAICS) code for this procurement is 334516 Analytical Laboratory Instrument Manufacturing with a small business size standard of 1,000. This acquisition is utilizing Full and Open (unrestricted) competition procedures.
From Combined Synopsis/Solicitation posted on Aug 27, 2025Inquiries and Responses: 1. Is there a required step distance between profiles for the topography evaluations? Response: For the spacing between profiles on the Type 1. Line height, width, or spacing standard, our focus is around 1mm, 5mm, or 10 mm for both line width and spacing. One order of magnitude difference between the listed values and those of the standards is acceptable, greater than that becomes a judgement call when justifying traceability (e.g., calibrating with a 5 micrometer standard when measuring 10 mm features is hard to justify). The takeaway: a reasonable leeway will be given when considering the requirement as met. Q2. Is it possible to specify the sa/sq tolerances? Response: For the Type 2. Roughness calibration standard, it will be accepted that the certificates list sa (arithmetic mean height) and/or sq (squared mean height) tolerances, for as long as the values are traceable to a National Metrology Institute. All other terms and conditions remain unchanged, as a resilt of this post. COMBINED SYNOPSIS/SOLICITATION 1333ND25QNB640339 Stylus Profilometer This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6 Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested, and a separate written solicitation document will not be issued. This solicitation is being issued under the authority of FAR Part 13 Simplified Acquisition Procedures. This solicitation is a Request for Quotations (RFQ) for a Stylus Profilometer. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisitions Circular (FAC) 2025-05, effective 8/7/2025. The associated North American Industrial Classification System (NAICS) code for this procurement is 334516 Analytical Laboratory Instrument Manufacturing with a small business size standard of 1,000. This acquisition is utilizing Full and Open (unrestricted) competition procedures.
From Combined Synopsis/Solicitation posted on Sep 05, 2025Notice history