Contacts, documents and full notice history are available with a subscription.
Sources Sought SBA Expired 1 notice 1 document

Steam Sterilizers 36C26325Q1063

Solicitation 36C26325Q1063 Copied Notice ID 758dd4d4a34244d0b0163d331e0af587 Copied VETERANS AFFAIRS, DEPARTMENT OF — NETWORK CONTRACT OFFICE 23 (36C263)
SAM.gov
Posted
Aug 04, 2025
Deadline
Aug 11, 2025
Set-aside
SBA
NAICS
339113
PSC
6515

Summary

AI-generated · Aug 24, 2025

Two steam sterilizers with a high-capacity chamber are being sought for purchase and installation by the Central Iowa Health Care System. This is a market-research, sources-sought effort limited to American-manufactured equipment; no proposals or pricing are requested or will be awarded from this notice. Responses should indicate the place of manufacture, and the information collected will help the government shape acquisition strategy and potential veteran-owned or other small-business set-aside considerations.

Key requirements include two units with pre-vacuum capability, external steam source, and a 20" x 20" x 38" footprint. Feature highlights include a control lockout, condensate alarm with cycle abort and safe venting, pressure-relief valve, vacuum pump to achieve prescribed vacuum and reduce water use, multiple RTDs for chamber and jacket temperature control, automatic utilities start-up/shutdown and programmable daily restart/shutdown, steam-activated gasket, advanced display with long-range visibility, permanent cycle record printer, and remote monitoring capability. Compliance must cover UL 61010-1 (via ETL), CAN/CSA-C22.2 No. 61010-1, and ASME Section VIII, Division 1 unfired pressure vessels (with ASME Form U-1 and a 45 psig design pressure).

The Central Iowa Health Care System requires the purchase and installation of 2 steam sterilizers with the salient characteristics listed below. This is a SOURCES SOUGHT NOTICE only looking for American manufactured equipment as listed below for market research purposes. No proposals are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS OR PRICING AND NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. The Buy American Act, FAR 52.225-1, applies. Interested vendors shall include the place of manufacture in their responses. Responses to this notice will be treated only as information for the Government to consider as part of their market research efforts. The information provided will be used by the Government in developing its acquisition strategy regarding possible set aside for Veteran Owned and other socio-economic categories of small business. Interested parties are responsible for adequately marking proprietary, restricted or competition sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this notice and parties responding will not be entitled to payment for direct or indirect costs incurred in responding to this notice. The North American Industry Classification System (NAICS) code for this requirement is 339113 Surgical Appliance and Supplies Manufacturing with an SBA Small Business Size Standard of 800 employees. The deadline for this information is 4:00 PM Central Time on Monday, August 11, 2025. Medium Steam Sterilizer features a high-capacity chamber. Control lockout switch - prevents cycle from starting until limit switch signal is received. If signal is lost during cycle, alarm activates, cycle aborts and chamber safely vents controlled exhaust. Chamber float switch - activates alarm, aborts cycle and safely vents chamber if detecting excessive condensate. Pressure relief valve - releases pressure buildup in chamber if approaching or reaching rated pressure. Vacuum pump effectively pulls chamber to specified vacuum levels and reduces water consumption. Resistance Temperature Detectors (RTD) are installed for sterilizer temperature control. Dual element chamber drain line RTD senses and controls temperature variations within sterilizer chamber. Dedicated RTD provides jacket-space temperature control. Electronic water saving control includes an RTD to control water quantity used in condensing chamber steam exhaust. Automatic utilities start-up/shutdown permits utilities conservation. Shutdown may be programmed to activate at a specific time of day. When used, utilities control automatically shuts off utility valves, conserving steam and water. Sterilizer utilities can be restarted automatically or manually. Different daily shutdown and restart times can be programmed Steam activated gasket requires no lubrication and is warranted for 2 years. Enhanced display is located at ergonomic height and features large cycle countdown visible from 15 feet away. Ink on paper impact printer provides permanent cycle record. Utilities usage is minimized with multiple temperature sensors. System operation can be continuously monitored with remote service monitoring. Must have the following approximate dimensions 20" x 20" x 38" Pre-vacuum Single Door External Supplied Steam (Facility Steam/Stand-Alone Generator) meet the applicable requirements of the following listings and standards, and carries the appropriate symbols: Underwriters Laboratory (UL) Standard 61010-1 as certified by ETL Testing Laboratories, Inc. CAN/CSA-C22.2 No. 61010-1. ASME Code, Section VIII, Division 1 for unfired pressure vessels. The pressure vessel is so stamped; ASME FormU- 1 is provided with shipment. Shell and door are constructed to withstand working pressure of 45 psig

From Sources Sought posted on Aug 04, 2025

Notice history

1
  1. Sources Sought LATEST Posted Aug 04, 2025

Details

Solicitation number 36C26325Q1063
Notice ID 758dd4d4a34244d0b0163d331e0af587
Notice type Sources Sought
Product / Service (PSC) 6515
NAICS 339113
Place of performance Des Moines, Iowa
Archive date Aug 26, 2025

Award Information

Not yet awarded

Documents

1
View on SAM.gov

Contacts

primary
Jennifer Watkins-Schoenig

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
NETWORK CONTRACT OFFICE 23 (36C263)

Place of Performance

Des Moines, Iowa 50310
USA

Dates

Posted Aug 04, 2025 1 year ago
Last Updated Aug 06, 2026 2 days ago
Due Aug 11, 2025 11 months ago