Special Notice - Intent to Sole Source Synopsis - Presby Advanced Enviro-Septic (AES) Wastewater Treatment System W9128A-26-Z-0006
Summary
AI-generated · Dec 19, 2025Capability statements from firms offering an alternative to the Presby AES wastewater treatment system must demonstrate the ability to fully meet the performance specifications required to treat Pohakuloa Training Area pre-treated wastewater to HAR 11-62-26 discharge limits. The system handles between 5,000 and 67,000 gallons per day of influent, with about 150 mg/L for both BOD5 and TSS, and must produce effluent of 60 mg/L or less for BOD5 and TSS. The Presby AES arrangement includes an 84,000-gallon septic tank feeding 12-inch corrugated perforated pipes with geotextile, coarse fibers, and bio-accelerator fabric, all on a sand filtration absorption bed, using passive treatment to reduce solids and BOD5 before soil discharge. Firms proposing alternatives should be prepared to show equivalent performance.
Submissions must include fully detailed specification sheets for the offered product (manufacturer name, address, and country of manufacture) and a two-page narrative explaining how the alternative is fully comparable and will operate in the same manner to deliver the same functionality. Email capability statements to Jennifer Ko and Christie Lee no later than January 6, 2026, 2:00 pm Hawaii Standard Time, at the addresses listed. The government will not reimburse any costs incurred in preparing or submitting information.
This is a notice of intent to acquire Presby Advanced Enviro-Septic (AES) Wastewater Treatment System to treat 5,000 gallons per day to 67,000 gallons per day of pre-treated wastewater influent generated from Pohakuloa Training Area (PTA) facilities to the effluent discharge requirements of Hawaii Administration Rules (HAR) section 11-62-26. The pre-treated wastewater influent is estimated to have a concentration of approximately 150 milligrams per liter (mg/L) for both BOD5 and TSS. Per HAR section 11-62-26, the treated wastewater generated from PTA facilities must meet effluent limits of 60 mg/L for BOD5 and 60 mg/L for TSS. The Presby AES Wastewater Treatment System receives the pre-treated influent from an 84,000 gallon septic tank and evenly distributes the wastewater to air vented 12-inch corrugated and perforated plastic pipes wrapped with geotextile, coarse fibers, and bio-accelerator fabric. The 12-inch pipes are manifolded and installed on a sand filtration absorption bed. The Presby AES Wastewater Treatment System uses passive treatment methodology to reduce suspended solids (TSS) and 5-day biochemical oxygen demand (BOD5) of the wastewater influent prior to discharge into the ground. Firms that believe they have an alternative to the Presby AES Wastewater Treatment system capable of fully meeting the performance specifications of the Presby AES Product may submit a capabilities statement. The capability statement shall be submitted by email to Jennifer Ko at jennifer.i.ko@usace.army.mil and Christie Lee at christie.s.lee@usace.army.mil no later than 6 January 2026, 2:00 pm., Hawaii Standard Time. The Government will not be responsible for any costs incurred in the preparation or submission of information in response to this announcement. The capability statement shall include the following: Provide fully detailed specification sheets for the product offered that is equivalent to the Presby AES wastewater treatment system. The specification sheets must include the manufacturer s name, address and country of manufacture. Provide a narrative, not exceeding two (2) pages, detailing how the alternate product offered is fully comparable to the Presby AES treatment system. The narrative should explain how your product will function and operate in the same manner, delivering the same functionality as the Presby AES wastewater treatment system.
From Special Notice posted on Dec 18, 2025Notice history
1Details
Award Information
Not yet awarded
Contacts
Phone
Agency
Place of Performance