Sources Sought Notice: Central Laboratory Vacuum System Replacement HFP-2025-128492
Summary
AI-generated · Aug 24, 2025Identify firms capable of planning and executing a full replacement of a central laboratory vacuum system in a federal facility. The project requires disconnecting and removing the existing system and installing a new skid-mounted, tri-plex (three-pump), dry oil-less unit with an integrated, manually switchable redundant control cabinet. The new system must fit the existing footprint, be compatible with the current receiver tank and building utilities, and operate continuously. Deliverables include a site survey, submittals (P&ID, general arrangement drawing, electrical panel dimensions, wiring diagrams) and documentation, delivery, installation in the mechanical penthouse, testing, commissioning, warranty service, installation/operations manuals, and a certificate of performance. Key specifications: inlet pressure 21–25 inHg, inlet temperature 80F, electrical 460 VAC 3-phase 60 Hz with 120 VAC control, 80 psi instrument air, and a footprint of about 5 by 7 feet.
Responses must demonstrate capability to perform construction or mechanical replacement of laboratory infrastructure, including experience in secure federal or laboratory environments, and indicate whether the firm can perform at least 51% of the work as a small business. Provide standard business information, relevant experience, past performance, and any applicable contract vehicles; indicate subcontracts if large business. Complete the required attachments (draft statement of work and an Excel SSN questionnaire) and submit within the page limit by the stated deadline, via the designated email, with the specified subject line; phone inquiries are allowed. No proprietary information should be included, and the government may use non-proprietary information in any resulting solicitation.
MARKET RESEARCH PURPOSES ONLY NOT A REQUEST FOR PROPOSAL OR SOLICITATION This is a Sources Sought Notice to determine the availability of businesses capable to perform a construction project involving the disconnection, removal, and full replacement of a central laboratory vacuum system. This notice is for planning purposes only, and does not constitute an invitation for Bids, Request for Proposal or Request for Quotation or an indication the Government will award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. Introduction The Food and Drug Administration (FDA) is conducting market research to identify small business concerns with the capability to perform a construction project involving the disconnection, removal, and full replacement of a central laboratory vacuum system. The work will be performed at the Harvey W. Wiley Federal Building in College Park, MD. The new system must meet stringent performance specifications, include a redundant control system, and be compatible with existing infrastructure. Tasks include site survey, submittals, delivery, installation, testing, commissioning, and warranty service. The period of performance is approximately 213 calendar days. This Sources Sought Notice is intended to gather capability statements and industry feedback to inform the Government s acquisition strategy, including potential small business set-aside considerations under FAR Part 19. Scope of Work The Contractor shall provide all labor, materials, equipment, supervision, and project management necessary to perform the full replacement of the existing Central Laboratory Vacuum System. The new skid-mounted, tri-plex (three-pump), dry (oil-less) system must include a manually switchable redundant control system integrated into the cabinet for operational continuity. The Contractor shall conduct a site survey and submit all required technical documentation for FDA review and approval, including a Piping and Instrumentation Diagram (P&ID), general arrangement drawing, electrical panel dimensions, and wiring diagrams. Following delivery, the Contractor will disconnect and remove the existing system, install the new system in the mechanical penthouse, and connect it to the building s existing utilities. The project also includes testing, commissioning, and submission of installation manuals and a certificate of performance. All work must comply with applicable technical, safety, and security requirements, and the Contractor is responsible for restoring any affected areas to their original condition upon completion. The Contractor shall furnish and install all necessary equipment required for the full replacement of the Central Laboratory Vacuum System. The new system shall be a skid-mounted, tri-plex (three-pump), dry (oil-less) vacuum unit capable of continuous operation and equivalent in capacity to the original RA0250 vacuum pumps. It shall include an integrated control cabinet housing a programmable, manually switchable A/B redundant control system to ensure uninterrupted operation in the event of primary controller failure. The system must be compatible with the existing receiver tank and be designed to operate within an inlet pressure range of 21 to 25 inches of mercury (Hg) and at an inlet temperature of 80F. All electrical components shall operate on 460 VAC, 3-phase, 60 Hz motor supply, with a control voltage of 120 VAC and support from an 80 psi instrument air supply. The complete assembly must fit within the existing mechanical footprint of approximately 5 feet by 7 feet. All piping, fittings, and associated connection materials necessary to integrate the system with existing vacuum, electrical, and drainage lines shall be provided by the Contractor. The final installation shall include all required monitoring instrumentation, electrical panels, and diagnostic capabilities, and must be accompanied by one electronic and two hard copies of the installation and operations manuals, along with a certificate of performance verifying the system meets all specified operational requirements. Capability Statements Responses to this sources sought notice shall unequivocally demonstrate the respondent s capabilities to provide the services listed above. Though the target audience is small business, all interested parties may respond. At a minimum, responses shall include the following: Business name and bio, Unique Entity Identifier (UEI), and CAGE code. Business address, business website, business size status (i.e., SB, VOSB, SDVOSB, HUBZone SB, SDB, WOSB, LB). Point of contact name, mailing address (if different from business address), phone number and email address. Summary of relevant experience performing construction or mechanical replacement projects involving laboratory infrastructure, such as central utility systems, vacuum systems, or similar mechanical installations. Demonstrated ability to manage construction projects in secure, federal, or laboratory environments. Statement indicating whether the company can perform at least 51% of the work under a small business set-aside, in accordance with FAR 52.219-14. List of applicable contract vehicles (e.g., GSA MAS, OASIS, NIH NITAAC, or agency specific IDIQs) If applicable, identification of the firm's GSA Schedule contract(s) by Schedule number and Schedule Item Numbers (SIN)s that are applicable to this potential requirement are also requested. If a large business, clarify if subcontracting opportunities exist for small business concerns. Respondents are encouraged to include any recent, relevant past performance, and to highlight specialized qualifications or technical expertise that align with the scope of this requirement. Descriptive literature, brochures, marketing material, etc. detailing the nature of services the responding firm is regularly engaged in providing. Response Instructions Responses must be limited to no more than 10 pages, excluding cover page and attachments, and submitted in PDF or Word format. In addition to the capability statement requirements above, respondents are required to review Attachment One Draft Statement of Work and complete Attachment Two SSN Questions as an excel document only as a part of their submission. All respondents should provide capability statements and provide in an excel format "Attachment Two" completed via email to Michele.Jackson@fda.hhs.gov and Freshta.Javid@fda.hhs.gov on or before August 21,2025 @ 10:00AM Eastern Standard Time. Phone calls about this sources sought notice will be accepted. Please include in the subject line of the email the following statement Sources Sought Central Laboratory Vacuum System Replacement HFP-2025-128492 from XXXXXX (Include your business name) Disclaimer and Important Notes: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre?solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation. Confidentiality: No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non?proprietary technical information in any resultant solicitation(s).
From Sources Sought posted on Aug 13, 2025This is a combined synopsis/solicitation forcommerical products and commercial services prepared in accordance with the format in subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. . The solicitation number is: HFP-2025-128492 and is issued as a request for quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2025-05. Offerors shall refer to the attached Statement of Work for a complete description of services, performance expectations, and deliverables .Description of requirement The Food and Drug Administration (FDA) requires a contractor to provide all labor, materials, equipment, supervision, and project management necessary to disconnect, remove, and fully replace the existing central laboratory vacuum system at the Harvey W. Wiley Federal Building in College Park, MD. The new skid-mounted, tri-plex (three-pump), dry (oil-less) system shall include a manually switchable redundant control system integrated into the cabinet, be compatible with existing infrastructure, and meet stringent performance specifications. Work includes site survey, required submittals, delivery, installation, connection to existing utilities, testing, commissioning, and warranty service.. Delivery information Acceptance shall be performed at the delivery locations. The FOB point is DESTINATION. Required delivery date or period of performance: September 29, 2025 to September 28, 2026 Place of performance: 5001 Campus Drive, College Park, MD 2074 The provision at 52.212-1, Instructions to Offerors-Commercial Products and Commercial Services, applies to this acquisition. Addenda to the provision is provided. Addendum to FAR 52.212-1: The quote validity period is to be 90 calendar days from date of quotation deadline. Question Deadline: The deadline for receipt of questions is Monday, September 8, 2025 at 12:00PM ET (Eastern Time). Quotation Deadline: The deadline for receipt of quotations is Wednesday, September 17, 2025 at 12:00 PM ET. Quotation submissions shall be submitted electronically to the primary and secondary POCs identified. Quotation Submission Instructions: Submit quotes to Primary and Secondary point of contact in notice via email that includes a detailed explanation of how the the specific tasks in the Statement of Work will be addressed as well the central vacum system that is being proposed. Pleae include pictures, diagrams, literature, technical and performance requirements of the central vacuum system being proposed. Use Attachment C - Pricing template to submit all Pricing. Reflect all discounts net in unit/extended prices (no separate lines) Include UEI, CAGE, Active SAM, and a POC in the Quote Offerors shall provide at least three (3) contract references completed within the past five (5) years that involved replacement of central laboratory vacuum systems or comparable mechanical utility projects in occupied facilities. Each reference shall include the client name, point of contact, contract or order number, scope, period of performance, and results achieved. Attachments: Attachment A - Combined Synposis Solicitation Attachment B - Statement Of Work Pricing Template Attachment C - Pricing Template
From Combined Synopsis/Solicitation posted on Sep 04, 2025*** FDA is providing responses to the questions that were receved from contractors **** Please refer to Attachment D - Responses to Question 128492 for details. This is a combined synopsis/solicitation forcommerical products and commercial services prepared in accordance with the format in subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. . The solicitation number is: HFP-2025-128492 and is issued as a request for quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2025-05. Offerors shall refer to the attached Statement of Work for a complete description of services, performance expectations, and deliverables .Description of requirement The Food and Drug Administration (FDA) requires a contractor to provide all labor, materials, equipment, supervision, and project management necessary to disconnect, remove, and fully replace the existing central laboratory vacuum system at the Harvey W. Wiley Federal Building in College Park, MD. The new skid-mounted, tri-plex (three-pump), dry (oil-less) system shall include a manually switchable redundant control system integrated into the cabinet, be compatible with existing infrastructure, and meet stringent performance specifications. Work includes site survey, required submittals, delivery, installation, connection to existing utilities, testing, commissioning, and warranty service.. Delivery information Acceptance shall be performed at the delivery locations. The FOB point is DESTINATION. Required delivery date or period of performance: September 29, 2025 to September 28, 2026 Place of performance: 5001 Campus Drive, College Park, MD 2074 The provision at 52.212-1, Instructions to Offerors-Commercial Products and Commercial Services, applies to this acquisition. Addenda to the provision is provided. Addendum to FAR 52.212-1: The quote validity period is to be 90 calendar days from date of quotation deadline. Question Deadline: The deadline for receipt of questions is Monday, September 8, 2025 at 12:00PM ET (Eastern Time). Quotation Deadline: The deadline for receipt of quotations is Wednesday, September 17, 2025 at 12:00 PM ET. Quotation submissions shall be submitted electronically to the primary and secondary POCs identified. Quotation Submission Instructions: Submit quotes to Primary and Secondary point of contact in notice via email that includes a detailed explanation of how the the specific tasks in the Statement of Work will be addressed as well the central vacum system that is being proposed. Pleae include pictures, diagrams, literature, technical and performance requirements of the central vacuum system being proposed. Use Attachment C - Pricing template to submit all Pricing. Reflect all discounts net in unit/extended prices (no separate lines) Include UEI, CAGE, Active SAM, and a POC in the Quote Offerors shall provide at least three (3) contract references completed within the past five (5) years that involved replacement of central laboratory vacuum systems or comparable mechanical utility projects in occupied facilities. Each reference shall include the client name, point of contact, contract or order number, scope, period of performance, and results achieved. Attachments: Attachment A - Combined Synposis Solicitation Attachment B - Statement Of Work Pricing Template Attachment C - Pricing Template Attachment D - Responses to Question 128492
From Combined Synopsis/Solicitation posted on Sep 09, 2025Notice history
3-
Sources Sought Posted Aug 13, 2025
-
Combined Synopsis/Solicitation Posted Sep 04, 2025View changes (4)
- Title: Sources Sought Notice: Central Laboratory Vacuum System Replacement → Central Laboratory Vacuum System Replacement
- Description: Description was updated
- Notice Type: Sources Sought → Combined Synopsis/Solicitation
- Response Deadline: Aug 21, 2025 → Sep 17, 2025
-
Combined Synopsis/Solicitation LATEST Posted Sep 09, 2025View changes (1)
- Description: Description was updated