Sources Sought: IRVHAFL Autoclave Install Electrical Prep Work HFP-2026-133044
Summary
AI-generated · Feb 27, 2026A market-research notice seeks qualified small businesses capable of performing electrical prep work for replacing four autoclaves at the FDA Irvine facility. The project requires electrical infrastructure modifications before installation, including upscaling panel capacity, new conduit and wiring, breaker and disconnect installations, panel schedule updates, and related electrical changes on both the first and second floor lab wings. Work must be done in an active laboratory and federal facility environment, with de-energizing procedures (LOTO) and proper labeling/documentation, and involves 150-amp 3-phase circuits, reconditioned Siemens breakers, fused disconnects, and various 120V/208V support circuits.
Respondents must be small businesses and indicate their size status. Interested firms should complete a Vendor Questionnaire in Excel (xlsx) addressing years of electrical experience, lab/federal facilities experience, 150-amp or greater 3-phase circuit work, panel upgrades and breaker installations, licensing (C-10) confirmation, and relevant project references. Submissions must be electronic via the xlsx questionnaire to the designated FDA contracting specialist, using the subject line: FDA IRV Autoclave Electrical Work Sources Sought Response [Company Name]. No marketing materials are requested.
Project Title: IRVHAFL Autoclave Install Electrical Prep Work Irvine, CA 1. Notice Type Sources Sought Small Business Market Research This is a Sources Sought Notice issued for market research purposes only. The Government is seeking information from qualified small businesses to assess industry capability, availability, and interest in the autoclave specialty electrical work at the FDA Irvine location. This is not a solicitation and does not constitute a commitment by the Government to issue a solicitation in the future. No contract will be awarded from this notice. The Government will not pay for information submitted in response to this notice. 2. Project Background The FDA Irvine Human and Animal Food Laboratory (IRVHAFL) is replacing four aging built-in autoclaves. The newly procured units have different electrical requirements than the existing units and require electrical infrastructure modifications prior to installation. The required work includes electrical panel capacity upgrades, new conduit and wiring installations, breaker installation, disconnect installation, panel schedule updates, and associated electrical modifications across first and second floor laboratory wings. Performance location: IRVHAFL 19701 Fairchild Rd. Irvine, CA 92612 3. Scope Summary The contractor must be properly licensed (C-10 Electrical Contractor or equivalent) and capable of performing work including, but not limited to: De-energizing existing autoclaves and implementing LOTO procedures Removal and replacement of conduit and wiring Installation of 150-amp 3-phase circuits Installation of reconditioned Siemens breakers Installation of fused disconnects Installation of 120V and 208V support circuits Panel upgrades and schedule updates Labeling and documentation Work in active laboratory and federal facility environments The contractor must provide service completion records upon completion. Period of performance begins upon award execution. 4. Small Business Participation FDA is seeking responses from Small Businesses. Respondents must indicate business size status under the identified NAICS code. 5. Submission Requirements Interested small businesses shall respond ONLY by completing and submitting the provided Vendor Questionnaire in xlsx format. No capability statements, brochures, or supplemental marketing materials are requested or will be evaluated. The questionnaire requires vendors to address: Years of commercial/industrial electrical experience Experience in laboratory/federal facilities Experience with 150-amp or greater 3-phase circuits Experience with panel upgrades and breaker installations Licensing confirmation (C-10) Relevant project references. Incomplete questionnaires may not be considered. 6. Response Instructions All responses are to be electronically provided via the xlsx format to Sr Contractor Contract Specialist, Sheneil Green, at Sheneil.green@fda.hhs.gov. Subject Line: FDA IRV Autoclave Electrical Work Sources Sought Response [Company Name] No phone calls will be accepted regarding this notice. 7. Disclaimer This Sources Sought Notice is for market research purposes only and does not constitute a Request for Quote (RFQ) or Request for Proposal (RFP). The Government reserves the right to determine the appropriate acquisition strategy based on responses received.
From Sources Sought posted on Feb 26, 2026Notice history
1Details
Award Information
Not yet awarded
Contacts
Phone
Agency
Place of Performance
USA