Sources Sought for Schneider Electric Power Logic ION8650B Meters N6274225SCHNEIDER
Summary
AI-generated · Aug 24, 2025Brand-name product is intended; NAVFAC Pacific is conducting a market survey to identify other sources that can supply meters with performance and listing/approval requirements equal to the Schneider Electric PowerLogic ION8650B (64 MB) for a Guam project. Three meters are needed that will be fully compatible with the existing Schneider PowerLogic ION Enterprise Control System servers in Building 3190, and will support revenue metering, cogeneration and IPP monitoring, compliance, power quality analysis, demand and power-factor control, load curtailment, equipment monitoring and control, energy pulsing and totalization, and outage notification.
Meters must meet detailed electrical, environmental, and communications specifications, including true RMS measurement with 1024 samples per cycle, high accuracy (0.1% for voltage/current and power, 0.001 Hz for power, 0.1% for energy), broad input voltage/current ranges, multiple input/output configurations, and support for multiple communication protocols (RS-232/RS-485, Ethernet, Modbus, DNP3, DLMS, IEC 61850 Ed.2, etc.). They should include appropriate digital I/O, isolation, environmental tolerances (-40 to 85 C operating, 5% to 95% RH non-condensing), and 64 MB memory. This is a market research request, not a bid or proposal; responses must provide detailed technical data demonstrating compatibility, with no brochures, and information becomes government property.
Notice of intent to use a brand name product. The Naval Facilities Engineering Systems Command, Pacific (NAVFAC Pacific) is performing a market survey to determine if other potential sources of supply can provide meters that have equal performance and listing/approval requirements to the Schneider Electric PowerLogic ION8650B, 64MB Memory Meter. FY26 Military Construction Army Project P-219 Pacific Deterrence Initiative: Guam Defense System, Forward Operating Sites, JR Marianas, Guam requires three (3) meters with the following characteristics: a. Fully compatible with existing Schnieder Power Logics ION enterprise control system platform servers in Building 3190. b. Application: Revenue metering, cogeneration and IPP monitoring, compliance monitoring, power quality analysis, demand and power factor control, load curtailment, equipment monitoring and control; energy pulsing and totalization, instrument transformer correction and outage notification. c. Type of measurement: True rms 1024 samples per cycle. Measurement accuracy 0.1% Reading for current and voltage 0.1% Power 0.001 Hz 0.1% Power factor 0.1% Energy d. Date update rate: 0.5 cycle or 1 second e. Input-voltage characteristics 57V to 277V V L-N rms nominal voltage 600 V L-L rms (9s) maximum voltage 5M?/Phase impedance Inputs: V1, V2, V3, VREF f. Input-current characteristics 1A, 2A, 5A and 10A rated nominal current 0.01-20A accuracy range 0.001-24A measurement range 500A rms for 1 second, non-recurring permissible overload Socket, 3W, 8VA/Phase, 3 Phase g. Standard Power Supply: 120-277V, L-N RMS (-15%/+20%) 47-63Hz or 120-480V, L-L RMS (-15%/+20%) 47-63Hz h. Auxiliary powered low voltage: AC: 65-120 (+/- 15%) VLN RMS, 47-63Hz DC: 80-160 (+/- 20%) VDC i. Auxiliary powered high voltage: AC: 160-277 (+/- 20%) VLN RMS, 47-63Hz DC: 200-300 (+/- 20%) VDC j. Digital Outputs: 4 (Form C) solid state relays (130V AC/200V DC) 50mA AC/DC, 1 (Form A) output k. Digital Inputs: up to 3 self-excited, dry contact sensing inputs l. Environmental: Operating Temperature: -40 Degree Celsius to 85 Degree Celsius Display Operating Range: -40 Degree Celsius to 70 Degree Celsius Storage Temperature: -40 Degree Celsius to 85 Degree Celsius Humidity Rating: 5% to 95% RH non-condensing Dielectric withstand: 2.5kV m. Communication: RS-232/RS-485 port (COM1): 300-115,200 baud (RS-485 to 57,600 bps); Protocols: ION, Modbus/RTU/Mastering, DLMS, DNP 3.0, GPSTRUETIME/DATUM Internal modem port (COM2): 300-57,600 bps ANSI 12.18 Type Optical Port (COM3): up to 57,600 bps RS-485 (COM4): up to 57,600 baud, Modbus, direct connection to a PC or Modem Ethernet port: 10/100BASE-T, RJ45 connector, protocols: DNP, ION, Modbus/TCP/Mastering, IEC 61850 Ed.2 or 100BASE-FX multimode, male ST connectors, DLMS EtherGate: Up to 31 Slave devices via serial ports ModemGate: Up to 31 slave devices n. Memory: 64MB This notification is for market research purposes only to identify if other potential sources of supply can meet the requirements of the Government. This is not a request for proposals, quotes, or an invitation for bid. The intent of this notice is to identify other potential sources of this product. To be considered, please submit detailed technical data in order for the Government to conduct a comprehensive evaluation of your product to ensure compatibility with the existing system. In accordance with FAR 15.201(e), a response to this notice is not an offer and cannot be accepted by the Government to form a binding contract. The responder is solely responsible for the information it submits and any associated costs. The Government reserves the right to disregard any submittal that is incomplete or vague. Please do not submit company brochures. Please submit complete information by electronic mail to Ms. Carly Essex at carly.t.essex.civ@us.navy.mil no later than 3 September 2025 at 2:00 p.m. H.S.T. Information received after the due date/time will not be considered. Any information provided to the Government in response to this Request for Information (RFI) will become U.S. Government property and will not be returned. All proprietary or classified information will be treated appropriately.
From Sources Sought posted on Aug 19, 2025Notice history
1Details
Award Information
Not yet awarded
Contacts
Phone