Site Visit - Awning and Installation 78190
Summary
AI-generated · Sep 28, 2025Manufacture and install two custom free-standing awnings with three side walls on existing concrete pads on the east-northeast side of Building 59. Each unit measures 19 ft 6 in long by 5 ft wide by 8 ft high, with a 2/12 shed/monopitch roof and a reverse slope—the highest point along the back wall—and includes gutters on all sides with downspouts at the two front corners. Legs must be buried 2 inches below the finished surface and secured with concrete; provide awning and wall installation instructions. Awnings must be weather-resistant and have a high wind rating of Category C per ASCE/SEI 7, Chap 26. Paint scheme requires primary Robins 22 or 32 with accent Robins 48 or 62, and installation is Awning #1 on Pad #1 and Awning #2 on Pad #2. The two notices are identical; no changes between them.
Manufacture and install two (2) free-standing awnings with walls according to the specifications detailed below. Install each awning on existing concrete pads (one awning per pad) on the East-Northeast side of Building 59. Bury the awning legs 2 inches below the finished surface and secure them with concrete. Provide awning and wall installation instructions. Specific Requirements: Two (2) custom free-standing awnings with 3 side walls Dimensions: 19 6 (length) x 5 (width) x 8 (height) 2/12 shed/monopitch roof, reverse slope with the highest point along the back wall. Gutters shall be manufactured and installed on all sides with down spouts located on the two front corners Material shall be weather resistant Structure shall have a high wind rating of Category C In accordance with (IAW) American Society of Civil Engineers (ASCE)/Structural Engineering Institute (SEI) ASCE/SEI 7, Chap 26. Paint Options: The primary color shall be ROBINS 22 or ROBINS 32 and any accent colors shall be ROBINS 48 or ROBINS 62. Installation: Awning #1 is to be installed on Pad #1, and Awning #2 on Pad #2.
From Special Notice posted on Sep 24, 2025Manufacture and install two (2) free-standing awnings with walls according to the specifications detailed below. Install each awning on existing concrete pads (one awning per pad) on the East-Northeast side of Building 59. Bury the awning legs 2 inches below the finished surface and secure them with concrete. Provide awning and wall installation instructions. Specific Requirements: Two (2) custom free-standing awnings with 3 side walls Dimensions: 19 6 (length) x 5 (width) x 8 (height) 2/12 shed/monopitch roof, reverse slope with the highest point along the back wall. Gutters shall be manufactured and installed on all sides with down spouts located on the two front corners Material shall be weather resistant Structure shall have a high wind rating of Category C In accordance with (IAW) American Society of Civil Engineers (ASCE)/Structural Engineering Institute (SEI) ASCE/SEI 7, Chap 26. Paint Options: The primary color shall be ROBINS 22 or ROBINS 32 and any accent colors shall be ROBINS 48 or ROBINS 62. Installation: Awning #1 is to be installed on Pad #1, and Awning #2 on Pad #2.
From Special Notice posted on Sep 25, 2025Notice history
2-
Special Notice Posted Sep 24, 2025
-
Special Notice LATEST Posted Sep 25, 2025No changes from previous notice
Details
Award Information
Not yet awarded
Contacts
Agency
Place of Performance
USA