Contacts, documents and full notice history are available with a subscription.
Combined Synopsis/Solicitation SBA Expired 2 notices 14 documents

RFP - Rewrite of Existing Technical Manual W911QY-25-R-A010

Solicitation W911QY-25-R-A010 Copied Notice ID 1d109c96e36c46f6923dd91c844eea93 Copied DEPT OF DEFENSE — W6QK ACC-APG NATICK
SAM.gov
Posted
Jun 18, 2025
Deadline
Jul 07, 2025
Set-aside
SBA
NAICS
541990
PSC
R425

Summary

AI-generated · Aug 25, 2025

Rewrite the CP DEPMEDS Technical Manual to reflect a shift from a four-level maintenance philosophy to a two-level maintenance approach in line with MIL-STD 40051-2 and DTD standards, and to incorporate updated JECP-based equipment. The manual must describe the replacement of legacy components with modern equivalents, including replacing the Alaska Shelter System with TEMPER Airbeam Supported shelters, substituting the Field Deployable Environmental Control Unit with a JECP 6-ton ECU, upgrading the M28 filtration kits to a 400 CFM Fan Filter Assembly, replacing TALPs and Protective Entrance airlocks with a JECP Multi-Person Airlock variant, and updating CB liners to sealed-zipper designs. It must also reflect the configuration change from the legacy Medical Re-engineering Initiative hospital layout to the modern Force Design Update layout, which uses four CP DEPMEDS set sizes: 32-bed HUB, 24-bed Surgical Augment, 32-bed Medical Augment, and 60-bed Intensive Care Ward.

Access to the Government Furnished Information comprises four restricted attachments. Requests must be submitted by email to the designated point of contact and include a signed DD2345 (signed by both the JCPO and the vendor) and a signed Standard Form 312, with the company’s EIN used instead of an individual SSN, and the government will grant access within five business days of receipt. The notice indicates the same scope and requirements as the prior notice, with no new changes between notices.

Please see attached Solicitation W911QY-25-R-A010 and accompanying enclosures. Government Furnished Information (GFI): There are four attachments listed as GFI in this Solicitation: 1. TM 10-8340-244-13&P TEMPER 2. TM 3-6665-430-13&P-1, JECP SAL PT 1 3. TM 3-6665-430-13&P-2, JECP SAL PT 2 4. TM 10-5410-286-14&P, CP DEPMEDS These documents are listed in SAM under restricted access. Vendors shall send all request for GFI via email to Andy Rhodes (andrew.r.rhodes10.civ@army.mil) by 5:00 PM EST on 30 June 2025. The request shall have the Subject Line: "W911QY-25-R-A010 Request for GFI" and shall include a signed DD2345 (must be signed by both the JCPO and the vendor) and a signed Standard Form 312 (Interested companies should use the company's EIN as opposed to an individual's SSN). The Government will grant access to these documents within 5 business days of receiving the request. The current version of the Chemically Protected Deployable Medical System (CP DEPMEDS) Technical Manual (TM) requires rewrite to address three aspects. The existing TM requires rewrite to reflect conversion from its existing four-level maintenance philosophy to a two-level maintenance compliant with the latest MIL-STD 40051-2 and Document Type Definition (DTD) standard. Several of the CP DEPMEDS components of the legacy CP DEPMEDS equipment sets have been replaced by modern components that are in use by the Joint Expeditionary Collective Protection (JECP) system. The rewritten CP DEPMEDS TM shall reflect these equipment changes, which include the following: Replacement of the existing framed tent systems (the Alaska Shelter System) to the modern TEMPER Airbeam Supported (TAS) shelter system. Replacement of the existing Field Deployable Environmental Control Unit (FDECU) with the JECP 6-ton Environmental Control Unit (ECU). Replacement of the existing M28 Simplified Collective Protection Equipment filtration support kits with the modern 400 CFM (Cubic Feet per Minute) Fan Filter Assembly (FFA). Replacement of the existing Tunnel, Airlock, Litter Patients (TALPs) and Protective Entrance (PE) airlocks with a variant of the JECP Multi-Person Airlock (MPE). Replacement of the existing chemical/biological (CB) protective liners with the modern equivalents that utilize sealed zippers to replace the two-track closures on the legacy liners. The rewritten CP DEPMEDS TM must reflect the change in configuration of the CP DEPMEDS equipment sets. The configuration of the CP DEPMEDS sets has changed from the legacy Medical Re-engineering Initiative (MRI) hospital configuration to modern Force Design Update (FDU) hospital configuration. The legacy MRI configuration included three CP DEPMEDs set sizes: a 40-bed set, a 44-bed set, and a 164-bed set. The modern FDU configuration includes four CP DEPMEDS set sizes: a 32-bed Hospital Unit Base (HUB) set, a 24-bed Surgical Augment set, a 32-bed Medical Augment set, and a 60-ned Intensive Care Ward set.

From Combined Synopsis/Solicitation posted on Jun 18, 2025

Please see attached Solicitation W911QY-25-R-A010 and accompanying enclosures. Government Furnished Information (GFI): There are four attachments listed as GFI in this Solicitation: 1. TM 10-8340-244-13&P TEMPER 2. TM 3-6665-430-13&P-1, JECP SAL PT 1 3. TM 3-6665-430-13&P-2, JECP SAL PT 2 4. TM 10-5410-286-14&P, CP DEPMEDS These documents are listed in SAM under restricted access. Vendors shall send all request for GFI via email to Andy Rhodes (andrew.r.rhodes10.civ@army.mil) by 5:00 PM EST on 30 June 2025. The request shall have the Subject Line: "W911QY-25-R-A010 Request for GFI" and shall include a signed DD2345 (must be signed by both the JCPO and the vendor) and a signed Standard Form 312 (Interested companies should use the company's EIN as opposed to an individual's SSN). The Government will grant access to these documents within 5 business days of receiving the request. The current version of the Chemically Protected Deployable Medical System (CP DEPMEDS) Technical Manual (TM) requires rewrite to address three aspects. The existing TM requires rewrite to reflect conversion from its existing four-level maintenance philosophy to a two-level maintenance compliant with the latest MIL-STD 40051-2 and Document Type Definition (DTD) standard. Several of the CP DEPMEDS components of the legacy CP DEPMEDS equipment sets have been replaced by modern components that are in use by the Joint Expeditionary Collective Protection (JECP) system. The rewritten CP DEPMEDS TM shall reflect these equipment changes, which include the following: Replacement of the existing framed tent systems (the Alaska Shelter System) to the modern TEMPER Airbeam Supported (TAS) shelter system. Replacement of the existing Field Deployable Environmental Control Unit (FDECU) with the JECP 6-ton Environmental Control Unit (ECU). Replacement of the existing M28 Simplified Collective Protection Equipment filtration support kits with the modern 400 CFM (Cubic Feet per Minute) Fan Filter Assembly (FFA). Replacement of the existing Tunnel, Airlock, Litter Patients (TALPs) and Protective Entrance (PE) airlocks with a variant of the JECP Multi-Person Airlock (MPE). Replacement of the existing chemical/biological (CB) protective liners with the modern equivalents that utilize sealed zippers to replace the two-track closures on the legacy liners. The rewritten CP DEPMEDS TM must reflect the change in configuration of the CP DEPMEDS equipment sets. The configuration of the CP DEPMEDS sets has changed from the legacy Medical Re-engineering Initiative (MRI) hospital configuration to modern Force Design Update (FDU) hospital configuration. The legacy MRI configuration included three CP DEPMEDs set sizes: a 40-bed set, a 44-bed set, and a 164-bed set. The modern FDU configuration includes four CP DEPMEDS set sizes: a 32-bed Hospital Unit Base (HUB) set, a 24-bed Surgical Augment set, a 32-bed Medical Augment set, and a 60-ned Intensive Care Ward set.

From Combined Synopsis/Solicitation posted on Jul 03, 2025

Notice history

2
  1. Combined Synopsis/Solicitation Posted Jun 18, 2025
  2. Combined Synopsis/Solicitation LATEST Posted Jul 03, 2025
    • Response Deadline: Jul 07, 2025Jul 09, 2025

Details

Solicitation number W911QY-25-R-A010
Notice ID 1d109c96e36c46f6923dd91c844eea93
Notice type Combined Synopsis/Solicitation
Product / Service (PSC) R425
NAICS 541990
Place of performance Aberdeen Proving Ground, Maryland
Archive date Jul 22, 2025

Award Information

Not yet awarded

Contacts

primary
Andrew R. Rhodes

Email

secondary
Dan Adams

Email

Agency

DEPT OF DEFENSE
DEPT OF THE ARMY
AMC
ACC
ACC-CTRS
ACC-APG
W6QK ACC-APG NATICK

Place of Performance

Aberdeen Proving Ground, Maryland
USA

Dates

Posted Jun 18, 2025 1 year ago
Last Updated Aug 06, 2026 1 day ago
Due Jul 07, 2025 1 year ago