RFI-Recommendation or Suggestion for a Replacement AC Unit FA3016FY2620TONAC
Summary
AI-generated · Feb 13, 2026Request for Information seeks recommendations for a comparable replacement for a 20-ton split air-conditioning unit. Replacement must be compatible with the current system specs: outdoor condenser nominal 20 ton (240,000 BTU/h), 208/230V 3-phase 60Hz, R-22 refrigerant, two-stage dual scroll compressors, two fans, efficiency up to 11.0 EER / 14.8 IEER, roughly 50.4 in H x 103.4 in W x 54.3 in D and weight of 1133 lb; indoor air handler nominal 20 ton (240,000 BTU/h), 3 HP blower motor, 8000 CFM, 208/230V 3-phase 60Hz, 4-row direct expansion cooling coil, 20-ton heating kit with 240V 3-phase 60Hz heating capacity 19.1 W and total amps 46 A. The statement of need and photos of the current unit are attached for reference.
This is an RFI for market research and not a solicitation or RFQ; responses will not result in a contract. Please submit any recommendations no later than Friday, February 20 at 16:00 CST.
This message is a Request for Information issued for market research purposes. We are looking for any recomendations or suggestions for a comparable replacement for a 20 TON Split A/C unit. The replacement needs to be compatible with the following specifications: Outdoor Unit (Condenser): Nominal Capacity: 20 TON (240,000 BTU/h) Voltage: 208/230V 3 Phase 60HZ Refrigerant TYPE: R-22 Compressors: 2-Stage (Dual) Scroll Compressors Fans: 2 Efficiency: Up to 11.0 EER / 14.8 IEER Dimensions: ~50.4 H x 103.4 W x 54.3 D Weight: 1133lbs Inside Unit (Air Handler): Nominal Capacity: 20 TON (240,000 BTU/h) Fan Motor Horsepower: 3HP Nominal Air Flow: 8000 CFM Electrical: 208/230 Volt, 3-Phrase, 60Hz Cooling Coil: 4-Row Direct Expansion (DX) Coil (Copper Tube, Aluminum Fin) Commercial Heat Element Kit For Air Handler Unit: 20 TON Voltage: 240Volts 3 Phase 60HZ 240 Volts, 3 Phrase Heating Capacity 19.1W Total Amps: 46 AMPS The Statement Of Need and pictures of the current unit are attached for reference. Please be advised this is an RFI only. This inquiry does not constitute a solicitation, a Request for Quote (RFQ), or a promise to issue and RFQ in the future. A contract will not be awarded based on responses to this notice. We kindly request that you provide any recommendations no later than, Friday, February 20th by 16:00 CST.
From Presolicitation posted on Feb 12, 2026Notice history
1Details
Award Information
Not yet awarded
Contacts
Agency
Place of Performance
USA