Repair Water Storage Tank 2, Bldg. 762, NAS Lemoore, CA N62473-25-R-J505
Summary
AI-generated · Aug 26, 2025Repair Water Storage Tank 2, Building 762 at NAS Lemoore requires demolishing existing components (tank gauge, float system, anodes for cathodic protection, roof vents and screens, overflow piping, roof hatch, ladder) and then constructing a renovated tank system per plans. After demolition, the contractor must clean and inspect the tank, provide a certified structural and leakage inspection report to NAVFAC FEAD CM at project closeout, and assess and recommend repairs for the Floating Spray Nozzle. Construction tasks include installing government-provided side vents, roof hatch and vents, new cathodic protection anodes, exterior stainless steel gauge board and cables, an 8-inch overflow pipe positioned 6 inches below the side vents, new stairs and landings, top railing, patching holes and severe corrosion, applying interior and exterior coatings, disinfecting per AWWA C652, and performing an operational check for NAS Lemoore staff, with all cleanup and disposal per NAS Lemoore requirements. Deliverables include as-built drawings, daily reports, and required closeout documentation to FEAD CM upon project completion.
Awarded to Bethel Downstream JV for $1,348,956.
1.3.1 Project Description The work includes B762 Repair Water Storage Tank 2 and incidental related work. Demo: 1. Drain Tank per NAS Lemoore requirements. 2. Demo existing wood gauge board, tank gauge and float system. 3. Demo existing anodes for cathodic protection system. 4. Remove existing metal roof vents and side screens. 5. Remove existing 3 inch diameter overflow piping. 6. Demo existing roof hatch. 7. Demo existing tank ladder. 8. Clean up and dispose of construction refuge per NAS Lemoore requirements. Construction: 1. Clean and Inspect Tank. Provide a certified tank inspection to include structural and leakage testing. Provide a certified report to NAVFAC Facilities Engineering and Acquisitions Division (FEAD) CM upon project closeout. 2. Inspect and provide recommendations for repair of the Floating Spray Nozzle. 3. Install new Goverment provided side vents per plans. 4. Install new roof hatch per plans and specifications. 5. Install new roof vents per plans and specifications. 6. Install new anodes on the cathodic protection system per plans and specifications. 7. Install new exterior stainless steel gauge board and SS cables for float/gauge system. 8. Install new 8 inch diameter pipe overflow 6 inches below the side vents. 9. Install new stairs and landings per plans and specifications. 10. Install new top railing per plans and specifications. 11. Patch holes and repair severe corrosion spots as needed. 12. Install new interior coating per plans and specifications. 13. Install new exterior coating per plans and specifications. 14. Disinfect Tank per AWWA C652. 15. Perform operational check to NAS Lemoore staff Standards. 16. Clean up and dispose of construction refuge per NAS Lemoore requirements. 17. Provide NAVFAC Facilities Engineering and Acquisitions Division (FEAD) CM with As-built drawings, Contractor daily reports and required documentation as specified to complete the scope of work upon project closeout.
From Award Notice posted on Jul 07, 2025Notice history
1Details
Award Information
Award Notices
Posted: Jul 07, 2025
1.3.1 Project Description The work includes B762 Repair Water Storage Tank 2 and incidental related work. Demo: 1. Drain Tank per NAS Lemoore requirements. 2. Demo existing wood gauge board, tank gauge and float system. 3. Demo existing anodes for cathodic protection system. 4. Remove existing metal...
Awardees
| Company Name | UEI | CAGE Code | Location |
|---|---|---|---|
| Bethel Downstream JV | LT2FZTK42669 | 9P5W4 | Anchorage, AK |