Contacts, documents and full notice history are available with a subscription.
Combined Synopsis/Solicitation NONE Expired 1 notice 6 documents

Repair Fire Sprinkler System-Facility 128, Vance AFB, Oklahoma XTLF25-1019

Solicitation XTLF25-1019 Copied Notice ID 989490a8003449fe8c3d0bea6be55cbe Copied DEPT OF DEFENSE — FA3029 71 FTW CVC
SAM.gov
Posted
May 20, 2026
Deadline
Jun 18, 2026
Set-aside
NONE
NAICS
23822
PSC
Z2NZ

Summary

AI-generated · May 21, 2026

Repair and replace the fire sprinkler system at Facility 128, Vance AFB, OK under a firm-fixed-price contract. Funding is not guaranteed at this time; an award will occur only if funds become available. The project requires removing the existing system and installing two new wet-pipe sprinkler systems per NFPA 13, 24, and 72, relocating risers to a designated mechanical room, and integrating fire alarm monitoring (valves, flow switches, and interconnections). It also includes hydraulic calculations and a water-supply test, installation of a Fire Department Connection and PIV valve, underground tie-ins, concrete repair, seismic bracing, new mains/branch lines, hangers, sprinkler heads, drains, inspector’s test connections, signage, flushing, acceptance/hydrostatic testing, final inspection, and delivery of as-builts, O&M manuals, warranties, and spare sprinklers. All work must follow the SOW, attached drawings, UFC 3-600-01, and applicable NFPA standards; field verification of existing conditions is required.

Submit a complete quotation package using the attached bid form, including total price for all labor, materials, testing, commissioning, and deliverables; technical submittals showing proposed components (cut sheets, model numbers, listings), NFPA compliance, and a draft schedule; and documentation of key personnel qualifications (NICET III Sprinkler Designer and an experienced installer). Quote validity is required for a specified period, and the award will be Lowest Price Technically Acceptable (LPTA) based on technical acceptability, licensing, scheduling ability, and price. A site visit is scheduled and attendance is strongly encouraged; questions must be submitted using the attached Q&A form by the deadline, and responses will be provided via an amendment. Access to the site will follow base security requirements.

Amendment #1 Quote Validity: The purpose of this amendment is to extend the required quote validity period. All offerors shall ensure their quotes remain valid for 180 days from the date and time of the solicitation closes. This extended timeframe will provide the government with the strongest opportunity to secure the necessary funding and ensure continuity in the procurement process. ASRC Federal Gulf State Constructors (AFGSC), as Prime Contractor to the United States Government, hereby solicits quotes from qualified firms for the following Firm-Fixed-Price requirement. Important Funding Notice: This requirement is unfunded at this time. Neither AFGSC nor the Government is obligated to award or reimburse proposal costs. Award will only occur when/if funding becomes available. AFGSC or the Government may cancel this solicitation at any time before or after the closing date. Description of Requirement: AFGSC requests Firm-Fixed-Price quotes to repair and replace the fire sprinkler system in Facility 128, Vance AFB, OK. Work includes, but is not limited to (Statement of Work is attached and in conjunction with this notice). Full removal of the existing fire sprinkler system Installation of two new wet-pipe fire sprinkler systems per NFPA 13 Relocation of sprinkler risers to the designated mechanical room Fire alarm interface work, including monitoring of valves, flow switches, and device tie-ins Hydraulic calculations and a new water supply flow test Installation of a new Fire Department Connection (FDC) Installation of a new PIV valve, underground tie-ins, concrete repair, and required thrust blocking Installation of new mains, branch lines, hangers, seismic bracing, and sprinkler heads Installation of auxiliary drains, inspector's test connections, signage, and identification System flushing, acceptance testing, hydrostatic testing, and final inspection Delivery of as-builts, O&M manuals, warranties, and spare sprinklers All work shall comply with: NFPA 13, 24, and 72 UFC 3-600-01 Specifications contained in the attached XTLF 25-1019 Repair Fire Sprinkler Specifications Drawings in XTLF 25-1019 Repair Fire Sprinkler Drawings AFGSC and Vance AFB requirements. Contractor must field verify all dimensions and existing conditions. Instructions to Offerors: Offerors must submit a complete quotation package including: 1. Firm-Fixed Price Proposal, using the attached bid sheet form and to include total cost for all labor, equipment, materials, testing, commissioning, and deliverables. 2. Technical Submittals, including: Proposed sprinkler system components (cut sheets, model numbers, listings) Confirmation of NFPA 13/24 compliance Draft schedule 3. Key Personnel Qualifications: NICET III Sprinkler Designer Qualified installer with documented fire sprinkler experience Quote Validity Certification through September 30, 2026. Email Quotes To: Betty Kliewer - betty.kliewer.ctr@us.af.mil NLT June 18, 2026 at 1:00 PM CST Late quotes will not be evaluated or accepted. Evaluation Criteria: This procurement will be awarded using Lowest Price Technically Acceptable (LPTA). Technical Acceptability Includes: Conformance with all specifications and drawings Correct licensing, NICET requirements, and experience Complete and compliant submittals Ability to meet schedule Compliance with NFPA codes and Vance AFB requirements Price; Lowest evaluated price among technically acceptable offers FFP only - no alternate pricing structures accepted Site Visit: A site visit is scheduled for May 28, 2026 at 10:00 AM CST at 400 Young Rd, Bld 200 Room 224. Attendance is strongly encouraged but not mandatory. If you intend to come you may email Betty Kliewer; betty.kliewer.ctr@us.af.mil and Shannon Perry; shannon.perry.1.ctr@us.af.mil 48 hours before scheduled time to ensure your name is on the list. Further instructions will be given upon email. Contractors/visitors must comply with Vance AFB access requirements, including REAL ID-compliant identification, vehicle insurance, and security vetting. Q&A Procedures: All questions must be submitted using the attached Q&A Form ONLY. Email completed forms to betty.kliewer.ctr@us.af.mil by the deadline of June 15, 2026. Additional questions will not be accepted after the cutoff. Responses will be provided via formal solicitation amendment. Offerors are responsible for checking SAM.gov for updates. Attachments: Specifications (SOW) Drawings Bid Form Wage Determination Q&A Form Vendor Information

From Combined Synopsis/Solicitation posted on May 20, 2026

Notice history

1
  1. Combined Synopsis/Solicitation LATEST Posted May 20, 2026 View

Details

Solicitation number XTLF25-1019
Notice ID 989490a8003449fe8c3d0bea6be55cbe
Notice type Combined Synopsis/Solicitation
Product / Service (PSC) Z2NZ
NAICS 23822
Set-aside No Set aside used
Place of performance Enid, Oklahoma
Archive date Jul 03, 2026

Award Information

Not yet awarded

Contacts

primary
Betty S. Kliewer

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE AIR FORCE
AIR EDUCATION AND TRAINING COMMAND
FA3029 71 FTW CVC

Place of Performance

Enid, Oklahoma 73705
USA

Dates

Posted May 20, 2026 2 months ago
Last Updated Aug 06, 2026 1 day ago
Due Jun 18, 2026 1 month ago