Repair AC Systems, Bldg 501, Maui, HI W50SLF-25-X-1A0U
Summary
AI-generated · Aug 24, 2025Replace the Building 501 air conditioning system: remove the existing Carrier air-cooled liquid chiller (40-ton nominal) and install a new 40-ton air-cooled chiller with identical or compatible specifications that can be integrated with the current ductwork and control systems. Also replace two close-coupled centrifugal chilled-water pumps (WEG NEMA Premium CC029A, 7.5 HP). This planning activity seeks interested sources for a project estimated between $250,000 and $500,000 and may be set aside for small business or open to all bidders depending on the response.
Respondents should provide a written notice of intent to bid as the prime contractor, a completed Source Sought Information Request Form, and a summary of relevant projects from the past three years (type, value, contract number, location, and point of contact), indicating prime or subcontractor status (if subcontractor, provide prime contractor name and point of contact). Include a brief outline of proposed resources, subcontractors, and key personnel to perform the contract. Submissions must be made by email (no faxes). Note: if adequate small-business competition is not available, the procurement may be advertised unrestricted, and subcontracting limitations under the applicable rules require the prime to perform a majority of the work with its own personnel or similarly situated subcontractors (75% cap for non-similarly situated subcontractors, excluding materials, for construction by special trade contractors).
Repair B1116 Roof, PMRF, HI Category: J Maint, Repair, and Rebuilding of Equipment Potential Sources Sought Date Published: August 2, 2025 Contact: Purchasing & Contracting Division, USPFO-HI, 91-1179 Enterprise Ave, Bldg. 117, Kapolei, HI 96707-2150, P.O.C.: SMSgt Cezar de Veas Synopsis: Repair AC Systems, Bldg 501, Maui, HI Work covered in this project includes but not limited to: Remove one (1) existing Carrier Air-Cooled Liquid Chiller (CH, Model 30RAP Size 040) serving Building 501 and replace it with one (1) new 40 Nominal Ton Air-Cooled Chiller. The new CH shall have at least identical specifications, quality, and standards; thus, it shall be compatible (or minor changes/improvements needed) with the current duct configuration and capable of being integrated with the existing control systems. Further, the CH system has two (2) close-coupled centrifugal chilled water pumps (WEG NEMA PREMIUM CC029A 7.5 HP) that also need replacement. The purpose of this synopsis is to gain knowledge of potential sources for this project including interested Small Business sources. This notice is for planning purposes only. All interested parties should respond. Hawaii Air National Guard Base, JBPHH-HI, 96853 intends to issue a solicitation and award of a contract to Repair AC Systems, Bldg 501, Maui, HI The magnitude of this project is between $250,000 and $500,000. All interested concerns will provide this office, in writing, a notice stating their positive intent to submit a proposal as a prime contractor no later than 08 Aug 2025. This notification, which shall not exceed ten (10) typewritten pages, must include (1) positive statement of intent to bid as a prime contractor, and (2) a completed and signed Source Sought Information Request Form and (3) A listing of projects completed during the past three years, both for government and private industry. The type of project, dollar value, Contract number, location, and Point of Contact are to be included. Indicate if you were prime or subcontractor, and if subcontractor, provide the name and point of contact for the prime contractor and (4) A brief outline of resources, subcontractors, and key personnel that would be used to accomplish the contract. In the event adequate Small Business contractors are not available for adequate competition for this project, it may be advertised as unrestricted. Information shall be provided via email to: cezar.y.deveas.mil@army.mil. Include the following in the subject line "Sources Sought W50SLF-25-X-1A0U". No facsimile responses will be honored. Your attention is directed to FAR Clause 52.219-14(e)(4) LIMITATIONS ON SUBCONTRACTING, Construction by special trade contractors which states, "By submission of an offer and execution of a contract, the Contractor agrees that in performance of the contract assigned a North American Industry Classification System (NAICS) code for in the case of a contract for Construction by special trade contractors, the concern will not pay more than 75 percent of the amount paid by the Government for contract performance, excluding the cost of materials, to subcontractors that are not similarly situated entities. Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 75 percent subcontract amount that cannot be exceeded, applies to this project if set aside for small business.
From Sources Sought posted on Aug 02, 2025Notice history
1Details
Award Information
Not yet awarded
Contacts
Phone
8088446340
Phone
Agency
Place of Performance
USA