Renovate Squadron Operations, Building 25, Project AXQD232620 AXQD232620
Summary
AI-generated · Nov 05, 2025Renovate Building 25 (approximately 25,000 sq ft) at Barnes Air National Guard Base, Westfield, MA. The work includes architectural, mechanical, electrical, telecom, and fire suppression/detection system upgrades, plus the installation of an Intrusion Detection and Access Control System. Non-classified spaces will be repaired to support expanded secure space and finishes, mechanical systems, and electrical distribution will be brought up to current standards. The project must meet ICD/ICS 705 requirements and UFC 4-010-01, using conventional design-construction methods.
This is a planning/market research Sources Sought to identify qualified vendors. Requirement is for firms with recent experience on large renovation projects (magnitude $10–$25 million) and, separately, projects where ICD 705 standards were integral within the past two years. Respondents should submit a Sources Sought Response form and up to five pages of supporting documentation describing the project type, ICD 705 applicability, project value, location, and whether the firm was prime or subcontractor (if subcontractor, provide the prime contact). This is not a request for proposals and does not obligate the Government to award; responses must be submitted in writing by the stated deadline.
Sources Sought Notice Renovate Squadron Operations, Building 25, Project AXQD232620, at Barnes Air National Guard Base, Westfield, MA. This notice is for planning purposes and market research only. The intent of this Sources Sought notice is to gain knowledge of the available vendor pool to determine: Interested vendors that have completed large renovation projects within the past 5 years with a magnitude of construction between $10,000,000 and $25,000,000. Interested vendors that have completed projects were Intelligence Community Directive (ICD) 705 (Sensitive Compartmented Information Facilities) standards were an integral part of the project and were successfully completed within the past 2 years. Description of Proposed Construction: Repair and renovate Building 25 (approx. 25,000 sq. ft.) to meet requirements of ICD/ICS 705 and UFC 4-010-01. Provide architectural, mechanical, electrical, telecom, and fire suppression/detection system improvements. Furnish Intrusion Detection and Access Control System (IDS/ACS). Repair non-classified spaces to accommodate expanded secure space and to bring finishes, mechanical systems and electrical distribution up to current standards. Project will comply with DoD Unified Facilities Criteria using conventional design and construction methods. All interested vendors will provide this office with a complete Sources Sought Response form and may include supplemental supporting documentation of projects completed. Ensure to describe the type of project, the extent that ICD 705 standards applied to the project, dollar value, contract number, location, and Points of Contact. Indicate if you were the prime or a subcontractor. If you acted as a subcontractor, provide the name and point of contact for the prime contractor. Limit your supporting documentation to 5 pages (not including the Sources Sought Response form). Information shall be provided via email to: 104.FW.MSC@us.af.mil. Include the following in the subject line "Sources Sought Notice Renovate Squadron Operations, Building 25". This is a "REQUEST FOR INFORMATION" only. This Sources Sought Notice is not a request for proposals and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing via email and submitted no later than November 19, 2025, at 2:00pm EST.
From Sources Sought posted on Nov 04, 2025Notice history
1Details
Award Information
Not yet awarded
Contacts
Agency
Place of Performance
USA