Contacts, documents and full notice history are available with a subscription.
Award Notice SDVOSBC 3 notices 1 document

R612--SUBSCRIPTION SOFTWARE CONTRACT 36C25625Q0985

Solicitation 36C25625Q0985 Copied Notice ID 59fbb411d6514ee4b3f04b11ef765411 Copied VETERANS AFFAIRS, DEPARTMENT OF — 256-NETWORK CONTRACT OFFICE 16 (36C256)
SAM.gov
Posted
Jun 06, 2025
Deadline
Jun 06, 2025
Set-aside
SDVOSBC
NAICS
513210
PSC
R612

Summary

AI-generated · Aug 23, 2025

Procure and implement Volpara Breast Health Software (Volpara Patient Hub and Volpara Risk) to accompany the mammography unit at the Overton Brooks VA Medical Center Radiology Service. The vendor will install the software, assume responsibility for design/architecture, provide ongoing technical support and maintenance, and deliver on-site and remote training for staff. The engagement covers a 12-month base period for installation and licensing, with four 12-month option periods for annual software licenses, remote support, and advisory services. The solution must integrate with RIS, PACS, workstations, and voice-recognition systems, including a two-way HL7 interface (ADT/ORM), DICOM-based third-party integration (e.g., PACS/RIS), FHIR, and PowerScribe 360 integration. Licenses include staff access to all features with reassignable licenses and a System Administrator license; on-site initial training (minimum two days) for four radiologists and remote training for staff are required, along with software updates and patches as needed.

Award notice confirms Volpara Health, Inc. as the selected vendor for $18,900 to provide the subscription software contract described above. This follows the prior sources-sought notice outlining the intended software and tasks and indicates the project will proceed under the stated scope at OBVAMC Radiology.

Statement of Work PURPOSE Overton Brooks VA Medical Center s Veteran population is increasing, and the need to provide Women's imaging services is a National Agenda Hot Topic Item. OBVAMC currently has no Mammography services due to a lack of equipment and is relying solely on OCC at a significant cost to the facility. Also, utilization of OCC consistently results in delays in receiving the outside report and is often overburdened on those in the process of obtaining these reports. Radiology requests approval to procure software/license through Volpara Breast Health Software to include Volpara Patient Hub and Volpara Risk software. The software will be purchased to accompany the mammography unit. The addition of the mammography unit and software will significantly improve Veteran access to care at OBVAMC. SCOPE: The vendor shall install all listed software (Volpara Patient Hub and Volpara Risk). All software must meet all salient characteristics defined in this section. The vendor shall furnish all design, transportation, labor, supervision, and training to provide Volpara Software in support of VISN 16. The software shall be delivered/installed to the designated location within this SOW. The Volpara software shall meet all applicable documents, standards, and publications in effect at the time of installation. The vendor must also have the capability of providing software for a 12-month base period with (4) 12-month option periods. PLACE OF PERFORMANCE: Overton Brooks VAMC, Radiology Service (OBVAMC) 510 E. Stoner Ave. Shreveport, LA 71101 2. PERFORMANCE PERIOD: The period of performance shall be a 12-month base for installation and support with four 12- Month option periods to provide annual software license, remote support, advisory/support services, and all other requirements under the U.S. Federal Software License and Services Agreement. 2.1 SPECIFIC TASKS AND DELIVERABLES: At a minimum; the contractor shall: Provide software based on the requirements and functionalities of this Statement of Work Maintain responsibility for their software design and architecture as approved by VA OIT Provide technical support and maintenance of the software Provide on-site and remote training to required end users (staff) Provide software updates and ongoing software patches as required 3. GENERAL REQUIREMENTS: 3.1. Software for these items should meet all functional requirements described herein. 3.2 SALIENT CHARACTERISTICS 3.2.1 Volpara Patient Hub and Volpara Risk Includes Features: Customizable patient tracking and report software worklists, patient record setup, and personal statistical report folders One-touch buttons to submit findings, assessments, conclusions, and final reports Risk calculations using multiple models, including Tyrer-Cuzick v8 Seamless integration into RIS, PACS, Workstation, and voice recognition workflows Easy and accelerated statistical reporting for FDA MQSA EQUIP inspection or ACR accreditation with simple exports Customize mammography workflow and speed of performance with automated reports and communications (Volpara Patient Hub) A full program for identifying and managing high-risk patients (Volpara Risk) Staff Licenses: Saff access to all features and functionality of patient HUB and Volpara risk Licenses may be reassigned among staff as needed System Administrator License: Access to all administrative controls and settings for system setup and maintenance Standard Interface - Patient Hub: HL7 interface between Patient Hub and a third-party software system via transfer of ADT, ORM, and/or ORU messages. See the Interface and Integration Summary section below for details on the interfaces included in this quotation. Third-Party Integration: Custom integration between Patient Hub and a third-party software system (e.g., PACS, RIS, digital reading workstations, and/or voice recognition systems) via DICOM Mammography CAD Structured Report or Fast Healthcare Interoperability Resource (FHIR). See the Interface and Integration Summary section below for details on the integrations included in this Quotation. Interface and Integration Summary: One 2-way HL7 interface (ADT and ORM) One PowerScribe 360 integration - Product PRODUCT NAME DESCRIPTION Patient Hub Risk Bundled Offering Volpara Breast Health Software Customizable patient tracking and reporting software - custom worklists, patient record setup, and personal statistical report folders. One-touch buttons to submit findings, assessments, conclusions, and final reports. Risk calculations using multiple models, including Tyrer-Cuzick v8. Seamless integration into RIS, PACS, workstation, and voice recognition workflows. Easy and accelerated statistical reporting for FDA MQSA EQUIP inspection or ACR accreditation with simple exports Staff Licenses Staff access to all features and functionality of Patient Hub and Volpara Risk Licenses may be reassigned among staff as needed. System Administrator License Access to all administrative controls and settings for system setup and maintenance Standard Interface - Patient Hub HL7 interface between Patient Hub and a third-party software system via transfer of ADT, ORM, and/or ORU messages See the Interface and Integration Summary section below for details on the interfaces included in This quotation. Third-Party Integration Custom integration between Patient Hub and a third-party software system (e.g., PACS, RIS, digital reading workstations, and/or voice recognition systems) via DICOM Mammography CAD Structured Report or Fast Healthcare Interoperability Resource (FHIR) Patient Hub Remote Product Training (hours) Remote initial product training to staff on Patient Hub features and functionality Patient Hub On-Site Initial Training (days) On-site initial training to staff on Patient Hub features and functionality Two (2) day minimum. 4. TRAINING: The vendor shall provide the following training: Patient Hub On-Site Initial Training (days) Onsite Training shall be a minimum of two days. Training will be for four Radiologists. Patient Hub Remote Product Training (hours) Remote initial product training (Patient Hub features and functionality) will be provided to staff.

From Sources Sought posted on Jun 06, 2025

Volpara Health

From Solicitation posted on Jun 06, 2025

Notice history

3
  1. Sources Sought Posted Jun 06, 2025
  2. Solicitation Posted Jun 06, 2025
    • Description: Description was updated
    • Notice Type: Sources SoughtSolicitation
    • Response Deadline: Jun 06, 2025Jun 20, 2025
    • Set-Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)None
  3. Award Notice LATEST Posted Jul 17, 2025

Details

Solicitation number 36C25625Q0985
Notice ID 59fbb411d6514ee4b3f04b11ef765411
Award number 36C25625P1109
Notice type Sources Sought
Product / Service (PSC) R612
NAICS 513210
Place of performance Shreveport, Louisiana
Archive date Aug 05, 2025

Award Information

Awardee
1
Total Awarded
$18,900.00
Award Date
Jul 15, 2025

Awardees

Company Name UEI CAGE Code Location
VOLPARA HEALTH, INC. LUSTJMLCP3T3 1BTF5 LYNNWOOD

Documents

1
View on SAM.gov

Contacts

primary
Angela Kennedy

Contract Specialist

Email

Phone

Agency

VETERANS AFFAIRS, DEPARTMENT OF
VETERANS AFFAIRS, DEPARTMENT OF
256-NETWORK CONTRACT OFFICE 16 (36C256)

Place of Performance

Overton Brooks VAMC Radiology Service
510 E. Stoner Avenue
Shreveport, Louisiana 71101
USA

Dates

Posted Jun 06, 2025 1 year ago
Last Updated Aug 06, 2026 1 day ago
Due Jun 06, 2025 1 year ago