Quaestor 8000 Standard W911S225U0848
Summary
AI-generated · Aug 23, 2025Requires a Quaestor 8000 Standard, a fully automatic test instrument capable of testing Drager PSS 7000SCBAs and Drager PAS-Colt Escape paks, for evaluating full-face masks, compressed air breathing apparatus, and closed-circuit breathing apparatus. It must include features such as an external microphone, gauge holder, low-pressure measuring point, test head with gel face, component storage area, CPS filling connection, medium- and high-pressure inlets/outlets, and an adjustable breathing volume of at least 134 L/min with an artificial-lung breathing rate of 5–38 strokes per minute. Accuracy must be <1 (per DIN EN 837); permissible air pressure range from 22 to 36 inHg; weight at least 45 lbs; storage temperature from -20°F to 136°F; high/medium/low pressure ranges of at least 350 bar, 25 bar, and -40 to +30 mbar respectively; adapters for 4500 psi and 3000 psi escape devices; external microphone connection; and a 24V power adapter compatible with 110/230V. Training on the new equipment must be provided by the seller.
Included components and ancillary items comprise a Quaestor case (3712635), a Q6/8k bypass relief valve (3731941), a spare 200-bar bar module with output (R58367), and Quaestor 8000 Training.
Salient Characteristics:001: Quaestor 8000 Standard: (R63260) Must be able to test Drager PSS 7000SCBA?s and Drager Pas-Colt Escape paks Must be a fully automatic test instrument for thetesting of full-face masks, compressed air breathing apparatus and closed-circuit breathingapparatus Must have training on new equipment provided by seller Must have an externalmicrophone Must have a gauge holder Must have a low-pressure measuring point Musthave a test head with gel face Must have a storage area for components Must have a CPSfilling connection Must have a medium pressure extractable inlet and a rotatable outletMust have a high-pressure inlet and outlet Must have a breathing volume of at least 134L/min The breathing frequency of the artificial lung must be at least 5 to 38 strokes a min.Must have a pressure sensor accuracy less than 1 according to DIN EN 837 Must havepermitted air pressure no less than 22 inHg and no more than 36 inHg Must weigh at least45 lbs. Must have a permitted low storage temperature of -20F and a permitted high storagetemperature of 136F Must have a high-pressure range of at least 350 bar Must have amedium pressure range of at least 25 bar Must have a low-pressure range of at least -40 to+30 mbar Must have adapters for 4500 psi systems and adapters for 3000 psi escapedevices Must have a connection for external microphone and external microphone must beprovided Must have a 24V power adapter for 110/230V power supply.002: Case Quaestor (3712635)003: Set Q6/8k bypass relief valve (3731941)004: Bar module, Spare set 200 bar module with output. (R58367)005: Quaestor 8000 Training
From Combined Synopsis/Solicitation posted on Jun 03, 2025Notice history
1-
Combined Synopsis/Solicitation LATEST Posted Jun 03, 2025
Details
Award Information
Not yet awarded
Contacts
Phone
Phone
Agency
Place of Performance
65473