Q522--Symbia Mobile Gamma Camera Rental 36C24726Q0347
Summary
AI-generated · Mar 11, 2026Provide full leasing, preventative maintenance, and repair services for one mobile gamma camera (Siemens Symbia mobile or compatible) for the Central Alabama Veterans Health Care System in Montgomery, AL, for a period of 6 to 8 months. The camera must include acquisition and processing software and be able to transmit to Philips VUE PACS via DICOM. Deliver and park the unit at 215 Perry Hill Road (near the Emergency Department), with installation within 30 days of award or project need, and provide a plan to minimize downtime at contract start, including anticipated maintenance and personnel training dates. Training must cover use, handling, and applications, and onsite instruction is required.
The contractor must provide OEM-certified preventative maintenance and repairs, with on-site service during normal business hours (7 am–4 pm) and 24/7 technical support. Repairs or replacements must occur within 48 hours if the unit fails to function or fails quality control tests, and work must be performed per OEM specifications to avoid voiding the warranty. All maintenance/repair service reports must be submitted to the COR and used to verify timeliness and functionality. The unit must be removed within one week after contract completion, and any hard drives storing patient data must be removed by the contractor and destroyed by approved VA HTM staff prior to removal. Training and on-site support shall be provided by the contractor.
Sources Sought Notice Request for Information for Symbia Mobile Gamma Camera Sources Sought Notice Page 3 of 4 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 4 STATEMENT OF WORK Mobile Dual Head Gamma Camera, Preventative Maintenance, and Repair Services Contractor shall provide full leasing, preventative maintenance, and repair services for one mobile gamma camera to Central Alabama Veteran s Healthcare System (CAVHCS) in Montgomery, Alabama. The expected Period of Performance is six to 8 months. REQUIRED EQUIPMENT AND THEIR RELATED KEY CHARACTERISTICS: QUANTITY EQUIPMENT DESCRIPTION KEY CHARACTERISTICS # 1 Siemens Symbia mobile GAMMA CAMERA Must be Siemens Symbia GAMMA CAMERA or compatible software so current Montgomery VA GAMMA CAMERA protocols can be transferred. Must include acquisition and processing software and must be able to transmit to Philips VUE PACS via DICOM data. SERVICES INCLUDED: The contractor shall deliver the gamma camera to 215 Perry Hill Road and park it in the lot just outside of building #1 in the designated location near the Emergency Department. The unit will remain onsite for 6 to 8 months from the date it arrives. The Contractor shall provide a plan to minimize the mobile gamma camera down-time for the start of the contract. Installation of the mobile GAMMA CAMERA unit shall take place within 30 days of award or customer need date, whichever is applicable due to construction timelines. This plan shall include anticipated maintenance and personnel training dates. Training shall include the use, handling, and applications training for the leased equipment. Onsite training shall be provided by the Contractor. The contractor shall be responsible for all maintenance and costs associated with repairs and will repair or replace the mobile unit within 48 hours as necessary if the equipment fails to function properly or pass quality control tests. Onsite repair services shall be offered during normal business hours from 7am to 4pm. Technical telephone support services for troubleshooting scopes and related equipment shall be available 24 hours a day, 7 days a week. The Contractor shall have the ability to repair/service the equipment per the Original Equipment Manufacturers (OEM) specifications in order to not void the leased equipment s warranty. The Contractor shall provide full preventative maintenance and repair service coverage for all contracted equipment. The preventative maintenance and repair services shall be completed by OEM certified service personnel. The contractor shall submit equipment service reports to the Contracting Officer s Representative (COR), confirming completion of said repair/maintenance service that was provided. Contract performance shall be monitored using this report, indicating the timeliness of the repair, the completion of the services provided, and shall act as a guide for confirming that the repaired equipment is operational. The Contractor shall remove the mobile GAMMA CAMERA unit within one week upon completion of the contract. Hard drives that store patient data will be removed by the contractor and given to an approved VA Healthcare Technology Management (HTM) staff member to be destroyed by the HTM staff at the completion of the contract and prior to removal of the GAMMA CAMERA mobile unit from 215 Perry Hill Road, Montgomery, AL 36109.
From Sources Sought posted on Mar 10, 2026Notice history
1-
Sources Sought LATEST Posted Mar 10, 2026
Details
Award Information
Contacts
Contract Specialist
Phone
None
Agency
Place of Performance
215 Perry Hill Rd.
Montgomery, AL 36109
USA