Contacts, documents and full notice history are available with a subscription.
Combined Synopsis/Solicitation NONE Expired 1 notice 1 document

PURCHASE OF TECNIPLAST DIGITAL VENTILATED CAGE (DVC) RACK NOI-NIAID-25-2266817

Solicitation NOI-NIAID-25-2266817 Copied Notice ID c61dc96a01b04568b58a39f852d8da2e Copied HEALTH AND HUMAN SERVICES, DEPARTMENT OF — NATIONAL INSTITUTES OF HEALTH NIAID
SAM.gov
Posted
Jul 10, 2025
Deadline
Jul 21, 2025
Set-aside
NONE
NAICS
332999
PSC
6515

Summary

AI-generated · Aug 25, 2025

Procure a digital ventilated cage (DVC) rack using Tecniplast DVC GM500 technology to support 160 cage spaces, with digital ventilation and 24/7 monitoring capabilities. The system must continuously monitor food and water availability, track spontaneous animal locomotion for welfare checks, and include daily evaluation of bedding moisture, plus 24/7 loss prevention against unexpected water events. It should offer customization to balance vivarium workload and provide data analytics including automated cage tracking, real-time data collection without disturbing animals, and the ability to filter, analyze, and display data. Only Tecniplast USA DVC system racks will meet these requirements and maintain compatibility with the existing DVC infrastructure. This is a sole-source requirement under 41 U.S.C. 1901(a)(1) as implemented by FAR 13.106-1.

Delivery to NIH, NIAID, 40 Convent Drive, Bethesda, MD 20814 is required within 10 days of receipt and acceptance of award. This is not a request for proposal. All responsible sources may submit a capability statement by email to Mildred Moss at mildred.moss@nih.gov by 10:00 am EST on July 21, 2025 (subject: NOI-NIAID-25-2266817), including evidence of Original Manufacturer parts obtained from Tecniplast USA Inc. Late submissions will be handled per FAR 52.212-1(f). The Government reserves the right to determine whether to compete the requirement.

This is a Notice of Intent (NOI), NOT a request for proposal. The National Institute of Allergy and Infectious Diseases (NIAID) of the National Institutes of Health (NIH) intends to negotiate on an other than full and open competition basis with Tecniplast, USA Inc., 1345 Enterprise Drive, West Chester, PA 19380, United States, to procure a digital animal cage. Minimum Requirements: The NIH seeks to procure an animal cage essential for enhancing animal welfare, improving research quality, and meeting modern standards in laboratory animal care and facility management. Specified below are required capabilities: Tecniplast USA Inc. DVC GM500 technology is required. Specifications below apply: Digital Ventilation required. 160 cage spaces required. Monitoring abilities required 24/7: food and water availabilities, monitoring of spontaneous animal locomotion to support welfare check Daily Evaluation of bedding condition based on real moisture content. 24/7 animal loss prevention due to unexpected water floods (bottle or AWS). Ability to customize, streamline, and balance Vivarium workload Data and Analytics: Automated cage tracking with real-time data collection, ability to collect animal activity data from cage with no disturbance to animals, ability to collect, filter, analyze, and display data Only Tecniplast USA DVC system racks are required to ensure full compatibility with the existing DVC infrastructure. Any other source of caging would fail to meet technical requirements, compromise research and operational efficiency, and result in the loss of prior investment. Therefore, the requested supply/service is the only solution that satisfies the requirement. Place of delivery: NIH, NIAID, 40 Convent Drive, Bethesda, MD 20814 Delivery date: Within 10 days of receipt and acceptance of award. The statutory authority for this sole source requirement is 41 U.S.C. 1901 (a) (1) as implemented by FAR 13.106-1 only one responsible source and no other supply of service will satisfy agency requirements. THIS IS NOT A REQUEST FOR PROPOSAL. All responsible sources that could provide the required items may submit a capability statement that will be considered by email (subject line to reference NOI-NIAID-25-2266817) to Mildred Moss at mildred.moss@nih.gov by 10:00 am EST, on July 21, 2025. All responsible sources that could provide the required cages must submit evidence of Original Manufacturer parts originally obtained from Tecniplast USA Inc. All responses received by the closing date of this synopsis will be considered by the Government. Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f). A determination not to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government.

From Combined Synopsis/Solicitation posted on Jul 10, 2025

Notice history

1
  1. Combined Synopsis/Solicitation LATEST Posted Jul 10, 2025 View

Details

Solicitation number NOI-NIAID-25-2266817
Notice ID c61dc96a01b04568b58a39f852d8da2e
Notice type Combined Synopsis/Solicitation
Product / Service (PSC) 6515
NAICS 332999
Set-aside No Set aside used
Place of performance Bethesda, Maryland
Archive date Aug 05, 2025

Award Information

Not yet awarded

Documents

1
View on SAM.gov

Contacts

primary
Tonia Alexander

Email

Phone

secondary
Mildred Moss

Email

Phone

Agency

HEALTH AND HUMAN SERVICES, DEPARTMENT OF
NATIONAL INSTITUTES OF HEALTH
NATIONAL INSTITUTES OF HEALTH NIAID

Place of Performance

Bethesda, Maryland 20814
USA

Dates

Posted Jul 10, 2025 1 year ago
Last Updated Aug 06, 2026 1 day ago
Due Jul 21, 2025 1 year ago