Combined Synopsis/Solicitation NONE Expired 3 notices 7 documents

Operation and Maintenance (O&M) of Defense Information Systems Network (DISN) Power Plants and Station Battery Systems FA520926Q0004

Solicitation FA520926Q0004 Copied Notice ID 4bc23ebf120445cd904c347ebf23db5f Copied DEPT OF DEFENSE — FA5209 374 CONS PK
SAM.gov
Posted
Jan 22, 2026
Deadline
Feb 26, 2026
Set-aside
NONE
NAICS
811210
PSC
M1BG

Summary

AI-generated · Jan 23, 2026

Contractor shall provide all personnel, equipment, tools, vehicles, materials, and supervision (excluding government-furnished items) to operate, maintain, and repair the electric generating plants, uninterruptible power supply (UPS), station battery systems, and applicable HVAC units and related equipment (rectifiers, inverters, etc.) located at Owada Communications Station, U.S. Fleet Activities Sasebo, Tokorozawa Transmitter Site, Camp Zama, Yokota AB 714 and MAN Shelters, as listed in Appendix A Equipment Listing. Work must be performed in accordance with the manufacturers’ instructions and applicable commercial standards, including any updates or changes to those standards.

The operation service is limited to the equipment listed in Paragraph 1.2.1.2, and preventive maintenance must follow this schedule: weekly at Owada, Tokorozawa, and 714 Yokota AB; bi-monthly (twice monthly) for MAN Shelters; and monthly at Zama and Sasebo.

The contractor shall provide all personnel, equipment, tools, vehicles, materials, supervision, except that specifically identified as Government furnished in Section 3, Government Furnished Property and Services, to operate, maintain, and repair the electric generating plants, uninterruptible power supply (UPS), station battery systems, applicable HVAC units and associated equipment (rectifiers, inverters, etc.); located at Owada Communications Station (Owada)(Saitama-ken, Niiza-shi, Nishibori 3 chome 8), U.S. Fleet Activities Sasebo (Sasebo)(Nagasaki-ken, Sasebo-shi, Hirase-cho), Tokorozawa Transmitter Site (Tokorozawa)(Saitama-ken, Tokorozawa-shi, Namiki 6 chome), Camp Zama (Zama)(Kanagawa-ken, Zama-shi, Zama), Yokota AB 714 and Metropolitan Area Network (MAN) Shelters)(Tokyo-to, Fussa-shi, Fussa) as listed in Appendix A, Equipment Listing, and in accordance with existing (IAW) manufacturer s instructions and commercial standards/practices, any updates, revisions, or changes made to them, or any new or emerging standards that are established. The contractor s operation service is required for the electric generating plants and its associated equipment only as listed in Para 1.2.1.2 below. Preventive maintenance is required weekly for Owada, Tokorozawa, and 714 Yokota AB. Preventive maintenance is required bimonthly (two times a month) for MAN Shelters. Preventive maintenance is required monthly for Zama. Sasebo is required on a monthly basis.

From Combined Synopsis/Solicitation posted on Jan 22, 2026

The contractor shall provide all personnel, equipment, tools, vehicles, materials, supervision, except that specifically identified as Government furnished in Section 3, Government Furnished Property and Services, to operate, maintain, and repair the electric generating plants, uninterruptible power supply (UPS), station battery systems, applicable HVAC units and associated equipment (rectifiers, inverters, etc.); located at Owada Communications Station (Owada)(Saitama-ken, Niiza-shi, Nishibori 3 chome 8), U.S. Fleet Activities Sasebo (Sasebo)(Nagasaki-ken, Sasebo-shi, Hirase-cho), Tokorozawa Transmitter Site (Tokorozawa)(Saitama-ken, Tokorozawa-shi, Namiki 6 chome), Camp Zama (Zama)(Kanagawa-ken, Zama-shi, Zama), Yokota AB 714 and Metropolitan Area Network (MAN) Shelters)(Tokyo-to, Fussa-shi, Fussa) as listed in Appendix A, Equipment Listing, and in accordance with existing (IAW) manufacturer s instructions and commercial standards/practices, any updates, revisions, or changes made to them, or any new or emerging standards that are established. The contractor s operation service is required for the electric generating plants and its associated equipment only as listed in Para 1.2.1.2 below. Preventive maintenance is required weekly for Owada, Tokorozawa, and 714 Yokota AB. Preventive maintenance is required bimonthly (two times a month) for MAN Shelters. Preventive maintenance is required monthly for Zama. Sasebo is required on a monthly basis.

From Combined Synopsis/Solicitation posted on Jan 26, 2026

The contractor shall provide all personnel, equipment, tools, vehicles, materials, supervision, except that specifically identified as Government furnished in Section 3, Government Furnished Property and Services, to operate, maintain, and repair the electric generating plants, uninterruptible power supply (UPS), station battery systems, applicable HVAC units and associated equipment (rectifiers, inverters, etc.); located at Owada Communications Station (Owada)(Saitama-ken, Niiza-shi, Nishibori 3 chome 8), U.S. Fleet Activities Sasebo (Sasebo)(Nagasaki-ken, Sasebo-shi, Hirase-cho), Tokorozawa Transmitter Site (Tokorozawa)(Saitama-ken, Tokorozawa-shi, Namiki 6 chome), Camp Zama (Zama)(Kanagawa-ken, Zama-shi, Zama), Yokota AB 714 and Metropolitan Area Network (MAN) Shelters)(Tokyo-to, Fussa-shi, Fussa) as listed in Appendix A, Equipment Listing, and in accordance with existing (IAW) manufacturer s instructions and commercial standards/practices, any updates, revisions, or changes made to them, or any new or emerging standards that are established. The contractor s operation service is required for the electric generating plants and its associated equipment only as listed in Para 1.2.1.2 below. Preventive maintenance is required weekly for Owada, Tokorozawa, and 714 Yokota AB. Preventive maintenance is required bimonthly (two times a month) for MAN Shelters. Preventive maintenance is required monthly for Zama. Sasebo is required on a monthly basis.

From Combined Synopsis/Solicitation posted on Feb 25, 2026

Notice history

3
  1. Combined Synopsis/Solicitation Posted Jan 22, 2026
  2. Combined Synopsis/Solicitation Posted Jan 26, 2026
    No changes from previous notice
  3. Combined Synopsis/Solicitation LATEST Posted Feb 25, 2026
    • Response Deadline: Feb 26, 2026Mar 04, 2026

Details

Solicitation number FA520926Q0004
Notice ID 4bc23ebf120445cd904c347ebf23db5f
Notice type Combined Synopsis/Solicitation
Product / Service (PSC) M1BG
NAICS 811210
Set-aside No Set aside used
Place of performance Fussa-shi, Tōkyō
Archive date Mar 13, 2026

Award Information

Not yet awarded

Contacts

primary
Mio Miyabayashi

Email

Phone

secondary
BENJAMIN WARREN

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE AIR FORCE
PACIFIC AIR FORCES
FA5209 374 CONS PK

Place of Performance

Fussa-shi, Tōkyō
JPN

Dates

Posted Jan 22, 2026 6 months ago
Last Updated Aug 06, 2026 2 days ago
Due Feb 26, 2026 5 months ago