NVARNG AASF Fuel Farm Pump and Motor Repair W9124X26QA004

Solicitation W9124X26QA004 Copied Notice ID 0e00ebf37b88449282f6b4e61f7140d6 Copied DEPT OF DEFENSE — W7NM USPFO ACTIVITY NV ARNG
SAM.gov
Posted
Apr 03, 2026
Deadline
May 05, 2026
Set-aside
SBA
NAICS
811310
PSC
J091

Summary

AI-generated · Apr 04, 2026

Replace the fuel farm motor, rebuild the pump, and repair the flow meter to ensure reliable fuel transfer from underground tanks into the refueling vehicles. Damage to the Scully switch and bypassed safeguards have stressed the motor, pump, and meter, risking motor seizure, overheating, and potential fire, which would prevent delivering fuel to the NVARNG’s refuelers.

Work is divided into three line items: motor replacement, pump rebuild, and meter repair. There is no current contract, and a site visit to view the equipment is available, though attendance is not required to bid. Proposals will be evaluated for price, conformance to technical requirements, and past performance, with awards going to the responsible offeror whose conforming bid is most advantageous. Full requirements are described in the attached documents.

Description of Requirements: (a) The United States Property and Fiscal Office Purchasing and Contracting Division on behalf of the NVARNG AASF requires fuel farm replacement of the pump motor, rebuild of the pump, and repair to the meter to reliably pull fuel from the underground tanks into the refueling vehicles. Previous damage to the fuel farm s Scully switch and bypass of the safeguards on it placed undue stress on the motor, pump and meter, which are beginning to fail. If the motor or pump seizes, the fuel farm will be unable to deliver fuel from the tanks into the HEMTT refueler vehicles. They also have the potential to overheat and set the fuel farm on fire. 1. Objectives: A. Replace the fuel farm Motor. B. Rebuild the pump. C. Repair the fuel meter. (b) There is no current contract for this requirement. (c) Dates with Line Item Numbers (LINs): (1) LIN 0001 Fuel Farm Motor Replacement (1-12 June 2026); (2) LIN 0002 Fuel Farm Pump Rebuild (1-12 June 2026); (3) LIN 0003 Fuel Farm Meter Repair (1-12 June 26) (d) The NVARNG is offering interested parties the opportunity for a site visit on 16 April 2026 at 11:00 A.M. PST in order to see the equipment that needs repairs. Site Address: Harry Reid Training Center 20000 Army Aviation Drive Reno, NV 89506 The site visit POC is Contract Specialist Andrew Simbeck. Interested parties do not have to attend to submit a quotation in accordance with FAR 52.237-1. The NVARNG will not offer other site visits. (e) Evaluation factors. The Government will award a contract resulting from this solicitation to the responsible Offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors will be used to evaluate offers: Price Conformance to Technical Requirements Past Performance (f) See attached "Solicitation - W9124X26QA004" and "PWS -Fuel Farm Motor and Pump" for a full description of requirements. (g) Questions/Clarifications submisison date and time: Tuesday, April 21, 2026 11:30 PM PDT. Responses will be consolidated and posted as an amendment to this solicitation.

From Solicitation posted on Apr 03, 2026

Amendment 0001 Questions from Industry with responses (also see attachment "W9124X26QA004 0001 Questions and Answers") Request For Information (RFI) 1: What is the make and model of the pumping unit? Gorman-Rupp Pumps Model No. RD3A31 BAR~ RFI 2: Motor nameplate data/specifications. The data plate is weather worn, but appears to state: NO C97000007 SER # C1904040472 SPEC 12-0000-0485 CAT. No. H.P. 40 T. CODE T3C VOLTS 460 AMPS 44 R.P.M. 3545 HZ 60 PH 3 CLASS H SER. F. 1.15 DES B CODE G RATING 4C AMB-CONT FRAME 324TS NEMA NOM EFF 92.4% UABLE @ 208V A PF 91% BALDOR ELECTRIC CO. FT. SMITH, AR U.S.A. NP0015XPSLEV RFI 3: Confirm whether the unit is mobile or installed at a fixed refueling rack location. Installed at a fixed refueling rack location. RFI 4: Drive configuration. Coupled system. RFI 5: Coupler model/type. Unfortunately, the manual does not go into this level of detail. RFI 6: Additional pictures of equipment. Included in attachment 'W9124X26QA004 0001 Questions and Answers." End of Amendment 0001 -------------------------------------------------- Description of Requirements: (a) The United States Property and Fiscal Office Purchasing and Contracting Division on behalf of the NVARNG AASF requires fuel farm replacement of the pump motor, rebuild of the pump, and repair to the meter to reliably pull fuel from the underground tanks into the refueling vehicles. Previous damage to the fuel farm s Scully switch and bypass of the safeguards on it placed undue stress on the motor, pump and meter, which are beginning to fail. If the motor or pump seizes, the fuel farm will be unable to deliver fuel from the tanks into the HEMTT refueler vehicles. They also have the potential to overheat and set the fuel farm on fire. 1. Objectives: A. Replace the fuel farm Motor. B. Rebuild the pump. C. Repair the fuel meter. (b) There is no current contract for this requirement. (c) Dates with Line Item Numbers (LINs): (1) LIN 0001 Fuel Farm Motor Replacement (1-12 June 2026); (2) LIN 0002 Fuel Farm Pump Rebuild (1-12 June 2026); (3) LIN 0003 Fuel Farm Meter Repair (1-12 June 26) (d) The NVARNG is offering interested parties the opportunity for a site visit on 16 April 2026 at 11:00 A.M. PST in order to see the equipment that needs repairs. Site Address: Harry Reid Training Center 20000 Army Aviation Drive Reno, NV 89506 The site visit POC is Contract Specialist Andrew Simbeck. Interested parties do not have to attend to submit a quotation in accordance with FAR 52.237-1. The NVARNG will not offer other site visits. (e) Evaluation factors. The Government will award a contract resulting from this solicitation to the responsible Offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors will be used to evaluate offers: Price Conformance to Technical Requirements Past Performance (f) See attached "Solicitation - W9124X26QA004" and "PWS -Fuel Farm Motor and Pump" for a full description of requirements. (g) Questions/Clarifications submisison date and time: Tuesday, April 21, 2026 11:30 PM PDT. Responses will be consolidated and posted as an amendment to this solicitation.

From Solicitation posted on Apr 20, 2026

Notice history

2
  1. Solicitation Posted Apr 03, 2026
  2. Solicitation LATEST Posted Apr 20, 2026
    • Description: Description was updated

Details

Solicitation number W9124X26QA004
Notice ID 0e00ebf37b88449282f6b4e61f7140d6
Notice type Solicitation
Product / Service (PSC) J091
NAICS 811310
Place of performance Nevada
Archive date May 20, 2026

Award Information

Not yet awarded

Contacts

primary
Andrew Simbeck

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE ARMY
NATIONAL GUARD BUREAU
JFHQ USPFO NV
USPFO NV PROCUREMENT
W7NM USPFO ACTIVITY NV ARNG

Place of Performance

Nevada 89506
USA

Dates

Posted Apr 03, 2026 4 months ago
Last Updated Aug 06, 2026 2 days ago
Due May 05, 2026 3 months ago