Contacts, documents and full notice history are available with a subscription.
Presolicitation Expired 1 notice

Notice of Intent to Sole Source- Super Resolution Microscope NB644020-25-01702

Solicitation NB644020-25-01702 Copied Notice ID 4799bdc4d6ff408389299ae05e3ea820 Copied COMMERCE, DEPARTMENT OF — DEPT OF COMMERCE NIST
SAM.gov
Posted
Aug 04, 2025
Deadline
Aug 19, 2025
Set-aside
None
NAICS
334516
PSC
6640

Summary

AI-generated · Aug 24, 2025

Acquire a super-resolution microscopy system for quantitative, nanometer- to micrometer-scale measurements of biological materials such as viruses, viral vectors, nanoparticles, and living cells. The instrument must be imaging-based with 100x magnification and include brightfield and fluorescence capabilities, specifically epifluorescence, highly inclined and laminated optical sheet (HILO) fluorescence, and total internal reflection fluorescence (TIRF) illumination. It must fit inside an existing biological safety cabinet, with a footprint no larger than 36" W x 24" D x 20" H and a maximum weight of 70 kg, and require no external vibration isolation beyond what the cabinet can provide. Operation must be at a class 1 laser level at all times due to safety constraints, given the lab’s biosafety setup.

Justification for sole-source: only the Oxford NanoImaging ONI NanoImager meets all three critical criteria—appropriate imaging capabilities, cabinet-fit footprint and weight, and class 1 laser operation—so the procurement will be awarded without competition under FAR 6.302-1. The system will be used with biosafety materials at levels 1–2+, and must integrate into a single conventional biosafety cabinet without additional measurement-specific enclosures.

Notice of Intent to Sole Source Agency Name: National Institute of Standards and Technology (NIST Description: The National Institute of Standards and Technology (NIST) intends to award a sole-source contract to Oxford NanoImaging Inc of San Diego CA, for a Super Resolution Microscope. The Biosystems and Biomaterials Division (BBD) of the National Institute of Standards and Technology requires a super-resolution microscopy system for the quantitative, spatial measurement of biological molecules in viruses, viral vectors, biological nanoparticles, and living cells. This need has three critical criteria, one related to the required capabilities and two related to safety, for integration into existing laboratory engineering safety controls and for the laser safety of the system itself. BBD has considered conventional format microscope systems that can deliver the needed measurement capabilities and found none that include both necessary safety criteria. BBD has also considered non-conventional format, integrated microscopy systems and found that only the Oxford Nanoimaging ONI Nanoimager instrument meets all three critical criteria of the Government's need. Justification: This sole-source procurement is justified under FAR 6.302-1, as Oxford NanoImaging is the only responsible source capable of providing the Super Resolution Microscope due to critical criteria 1, the system must be imaging based with brightfield and fluorescence modes hardware capabilities for 100x magnification, epifluorescence illumination, highly inclined and laminated optical sheet (HILO) fluorescence illumination, and total internal reflectance fluorescence (TIRF) illumination. These criteria are necessary for the single system to be capable of providing required measurements across the nanometer to micrometer length scales presented by the range of biological materials BBD currently needs to measure and characterize. Critical criteria 2, the system must be compatible with placement inside an existing, conventional biological safety cabinet (BSC) within BBD's laboratories. As such, the system must have an overall footprint no larger than 36" x 24" x 20" (w x d x h) to fit within the working volume of the BSC. In addition, the system must be constructed so as not to require any external vibration isolation or stabilization in excess of a placement surface that can support the physical weight of the system with a maximum system weight of 70 kg. These criteria are necessary since the biological materials to be studied by BBD include biological materials at biosafety levels 1 to 2+ and, therefore, require a biosafety enclosure for operator (person) protection during manipulations of the measurement samples. Furthermore, BBD needs to incorporate these new measurement capabilities into an existing laboratory space with one conventional BSC and no capacity to accommodate any measurement instrument-specific biological safety enclosures. Critical criteria 3, the system must operate as a class 1 laser device at all times during user operation. BBD's existing laboratory space for these measurements with biological materials is not equipped with the necessary engineering controls that would allow safe operation of laser devices classified above class 1 during user operation, and such engineering modifications are not currently feasible. Contact Information: For inquiries, please contact Don Graham, Contracting Officer at donald.graham@nist.gov

From Presolicitation posted on Aug 04, 2025

Notice history

1
  1. Presolicitation LATEST Posted Aug 04, 2025 View

Details

Solicitation number NB644020-25-01702
Notice ID 4799bdc4d6ff408389299ae05e3ea820
Notice type Presolicitation
Product / Service (PSC) 6640
NAICS 334516
Place of performance Gaithersburg, Maryland
Archive date Sep 03, 2025

Award Information

Not yet awarded

Documents

No files available

View on SAM.gov

Contacts

primary
Don Graham

Email

Phone

Agency

COMMERCE, DEPARTMENT OF
NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY
DEPT OF COMMERCE NIST

Place of Performance

Gaithersburg, Maryland 20899
USA

Dates

Posted Aug 04, 2025 1 year ago
Last Updated Aug 06, 2026 1 day ago
Due Aug 19, 2025 11 months ago