Contacts, documents and full notice history are available with a subscription.
Special Notice SBA Expired 1 notice 2 documents

NOCA-MXRD 250030-Rpr (Sustain) Chilled Beam HVAC and Controls, Service and Maintenance FA2835-26-1564

Solicitation FA2835-26-1564 Copied Notice ID cf2f11f6e83e4ab780b5866a4bf1f780 Copied DEPT OF DEFENSE — FA2835 AFLCMC HANSCOM PZI
SAM.gov
Posted
Nov 26, 2025
Deadline
Dec 11, 2025
Set-aside
SBA
NAICS
238210
PSC
J059

Summary

AI-generated · Nov 27, 2025

Provide ongoing preventative maintenance and timely repairs for the Chilled Beam HVAC system and its controls, including connectivity to master controls in the designated buildings. The goal is to keep the system responsive to weather and seasonal changes, improve efficiency, and prevent malfunctions that affect temperature, humidity, and condensation in occupied spaces.

Include training of base personnel to restore, operate, and modify programming of the existing system. Require trained and certified technicians to service, maintain, and train base personnel on a custom, multi-integrated control system using KMC, Delta, Semco, Schneider, Lochinvar, and Niagara controllers to ensure maximum performance year-round. The contract must verify existing conditions, calibrate and program the system, update graphics, perform testing and performance verification, produce shop drawings, and provide O&M documentation. See attached SSJ for additional detail.

The intent of this effort is to provide regular preventative maintenance and timely repairs to the Heating, Ventilation and Air Conditioning (HVAC) Chilled Beam System and System Controls in building XXXX and connectivity to master controls in building XXXX. This will ensure the HVAC system stays responsive to the weather, seasonal changes, and improved efficiency. This action will mitigate system malfunctions by maintaining temperature, humidity and the elimination of condensation buildup in occupied spaces consistently. Furthermore, this action will result in the training of base personnel, to restore, operate, and make programming changes to the existing HVAC system. Trained/Certified technicians are required to service, maintain, and train base personnel on custom multi-integrated KMC, Delta, Semco, Schneider, Lochinvar, Niagara controllers control system and perform activities to ensure maximum HVAC (Chilled beam) system controls maintain operational capability during all seasons. The service contract requires verification of existing conditions, calibration, programming, graphics, testing, performance verification, shop drawings, and O&M documents. See attached SSJ for additional detail.

From Special Notice posted on Nov 26, 2025

Notice history

1
  1. Special Notice LATEST Posted Nov 26, 2025 View

Details

Solicitation number FA2835-26-1564
Notice ID cf2f11f6e83e4ab780b5866a4bf1f780
Notice type Special Notice
Product / Service (PSC) J059
NAICS 238210
Place of performance Hanscom AFB, Massachusetts
Archive date Dec 12, 2025

Award Information

Not yet awarded

Contacts

primary
Jenny Desaulniers

Email

secondary
Michelle Huard

Email

Agency

DEPT OF DEFENSE
DEPT OF THE AIR FORCE
AIR FORCE MATERIEL COMMAND
AIR FORCE LIFE CYCLE MANAGEMENT CENTER
FA2835 AFLCMC HANSCOM PZI

Place of Performance

Hanscom AFB, Massachusetts 01731
USA

Dates

Posted Nov 26, 2025 8 months ago
Last Updated Aug 06, 2026 1 day ago
Due Dec 11, 2025 7 months ago