Multi-Therapy Infusion Pump FA4417MTPUMP
Summary
AI-generated · Apr 09, 2026Portable, multi-therapy infusion pump for use in pre-hospital, aeromedical, and military environments that is small, lightweight, and rugged enough to fit into medical packs and rucksacks. It will be operated by licensed military healthcare professionals for intravascular, subcutaneous, intra-arterial, epidural, and perineural infusions in clinical, ambulatory, and medical transport settings (air and ground).
Must meet strict size/weight, power, and ruggedness requirements: dimensions under 6 x 4 x 2 and weight under 15 oz (excluding battery); supports continuous, PCA, intermittent, multi-step, TPN, and epidural infusions; flow 0.1–999 mL/h with 2.5% accuracy; VTBI 0.1–9,999 mL; drug library up to 40 care areas and at least 1,000 drugs per area. Power via AC 100–240V and rechargeable Li-Ion battery with at least 24 hours of continuous operation at 125 mL/h. Features include a wet-enters operable touchscreen, a rugged, splash- and drop-resistant casing, and operation from +5°C to +40°C; MIL-STD-461G EMI/EMC compliance; Safe-to-Fly aeromedical certification; current FDA clearance for indicated uses; wired data connectivity with USB adapters for compatibility with modern systems; consideration of proprietary consumables. Vendors should submit a capability statement or white paper demonstrating compliance with all specifications. Submissions per SAM.gov announcement.
1.0 Product Overview: This document outlines the requirements for a small, lightweight, and durable multi-therapy infusion pump designed for use in pre-hospital, aeromedical, and military environments. The Office of the Command Surgeon is seeking a portable device that offers a wide range of therapeutic applications in a compact and rugged form factor, capable of reliable function in demanding field conditions. The intended use for this device is for intravascular, subcutaneous, intra-arterial, epidural, and perineural infusions administered by licensed military healthcare professionals in clinical, ambulatory, and medical transport settings (both air and ground). 2.0 Core Capabilities and Specifications: The primary requirements for the infusion pump are focused on size, weight, and cube (SWaP) to ensure it can be seamlessly integrated into already existing medical pack-outs and ruck sacks. Feature Required Specification Dimensions Objective: Less than 6 x 4 x 2 Weight Less than 15 oz (excluding battery) Delivery Modes Must support: Continuous, Patient-Controlled Analgesia (PCA), Intermittent, Multi-Step, Total Parenteral (TPN), and Epidural infusions. Flow Rate 0.1 mL/h to 999 mL/h Flow Rate Accuracy 2.5% under normal conditions Volume to be Infused 0.1 mL to 9,999 mL Drug Library Must support up to 40 clinical care areas and at least 1,000 drugs per area. Power Source AC: 100-240V, 50-60 Hz DC: Rechargeable Li-Ion battery Battery Life Minimum of 24 hours of continuous operation at a rate of 125 mL/h. Environmental Device must feature a touch screen that is fully operable when wet. The casing must be designed to withstand drops and fluid splashes. Operating Temperature +5C to +40C (41F to 104F) The device must meet the following minimum standards for military and aeromedical use: Electromagnetic Compatibility: Must meet MIL-STD-461G for Electromagnetic Interference (EMI) and Compatibility (EMC). Aeromedical Certification: Must be certified as "Safe-to-Fly" for use in military and commercial air transport. FDA Clearance: The device must have current FDA clearance for the indicated uses. Technical Considerations: The device must be capable of wired data connectivity. While a non-standard serial port is acceptable, it must be supplied with an appropriate adapter to ensure connectivity with modern computer systems (e.g., USB). Consumables: Please specify if the infusion pump system requires proprietary consumables (e.g., administration sets). Performance Testing: The device will be subject to a series of performance checks measuring the Volume to be Infused (VTBI) to validate accuracy and reliability. Submission: In response to this request for information, vendors shall submit a capability statement or white paper demonstrating that the proposed items meet all outlined specifications. Submissions must be received by the date specified in the SAM.gov announcement and submitted to the point of contact identified therein.
From Sources Sought posted on Apr 08, 2026Notice history
1Details
Award Information
Not yet awarded
Contacts
Phone
Phone
Agency
Place of Performance
USA