AI-generated · Aug 24, 2025

Two Primary Standard Liquid Flow Calibrators (or equivalent) are being sought as a life-cycle replacement for an aging unit at Redstone Arsenal where repair parts are no longer available. This is market research to identify capable sources that can provide two units delivered to APSL, Building 5435, Fowler Road, Redstone Arsenal.

Key requirements (or equivalent): maximum measurement capability up to 60 GPM; includes CFlow+ software; temperature control (heating and cooling); manual and automatic operation; accessible temperature probes and components for easy calibration; fluid draw plumbing attachment; measurement uncertainty of 0.05% or better at k=2; compatibility with all turbine meters and flowmeters (rotameters, frequency output, analog output).

The US Army Contracting Command-Redstone Services & IT Solution Branch, plans to obtain information to serve as market research to help identify potential sources that can provide two (2) Primary Standard Liquid Flow Calibrators or equivalent for a life-cycle replacement for an older similar calibrator that is becoming inoperable due to repair parts being unavailable. The equipment shall be delivered to APSL, located at Building 5435, Fowler Road Redstone Arsenal. The Liquid Flow Calibrators module shall include the following specifications or equivalent (if not brand name): Maximum measurement capability of 60 GPM Utilize CFlow+ software Provide temperature control of fluids (heating and cooling) Manual and automatic operation Access to temperature probes and other components to provide for easy calibration Fluid draw plumbing attachment Flow calibrators must have an uncertainty of 0.05% or better at k=2 Flow meter calibrators must be compatible with all turbine meters and flowmeters (rotameters, frequency output, analog output)

From Sources Sought posted on Jun 18, 2025

Notice history

1
  1. Sources Sought LATEST Posted Jun 18, 2025 View

Details

Solicitation number PANRSA-25-P-0000-014828
Notice ID c81c775f1f7045df92ef65c015a49840
Notice type Sources Sought
Product / Service (PSC) 6680
NAICS 334514
Place of performance Redstone Arsenal, Alabama
Archive date Jul 18, 2025

Award Information

Not yet awarded

Contacts

primary
Taylor Siskoff

Email

secondary
Shalanda McMurry

Email

Agency

DEPT OF DEFENSE
DEPT OF THE ARMY
AMC
ACC
ACC-CTRS
ACC RSA
W6QK ACC-RSA

Place of Performance

Redstone Arsenal, Alabama 35898
USA

Dates

Posted Jun 18, 2025 1 year ago
Last Updated Aug 06, 2026 1 day ago
Due Jul 03, 2025 1 year ago