Contacts, documents and full notice history are available with a subscription.
Sources Sought Expired 2 notices 1 document

LGA Visual Monitoring and Security Updates W912EF26RSS06

Solicitation W912EF26RSS06 Copied Notice ID 839ede5e109644e2bfc34ed7a10fab4c Copied DEPT OF DEFENSE — US ARMY ENGINEER DISTRICT WALLA WAL
SAM.gov
Posted
Jan 06, 2026
Deadline
Jan 19, 2026
Set-aside
None
NAICS
N/A
PSC
N/A

Summary

AI-generated · Jan 07, 2026

Security Upgrades at Little Goose Lock and Dam require a firm-fixed-price construction contract to install new security barriers and related site work at the Little Goose Visual Monitoring project. Work includes concrete saw cutting for underground electrical trench, sidewalk demolition and replacement, misc concrete footings, installation of bollards, fence and gate demolition and replacement with motor-operated cantilevered gate, fencing around the base of an exterior staircase, and installation of conduits (rigid metal and underground PVC). The project also involves asphalt repair and other miscellaneous tasks as shown in the plans, with responsibilities for submittals and as-built drawings.

Rigorous on-site safety and quality control are mandatory. The contractor must implement an EM 385-1-1-compliant Safety and Health program, including a comprehensive Accident Prevention Plan, Activity Hazard Analyses, and a Fall Protection Plan, with a Site Safety and Health Officer on every shift (minimum 5 years of construction safety experience, 30-hour OSHA training in the last 5 years, and 24 hours of safety training per year for the past 5 years). A Contractor Quality Control system is required, with a qualified CQC System Manager on each shift (minimum 5 years in a supervisory/management role and recent Construction Quality Management training). The project will use the Government-furnished QCS RMS software for records and submittals (pre-construction plans, product data, test reports, close-out docs, and as-built drawings). Interested small firms should submit a capability statement detailing qualifications, relevant past projects, bonding capacity, small business status/type, and a point of contact for contracting, to assist in determining whether the work should be set aside.

The U.S. Army Corps of Engineers, Walla Walla District is seeking small business sources for a construction project entitled Little Goose Visual Monitoring Project Security Upgrades The work is located near Starbuck, Washington at the Little Goose Lock and Dam, Juvenile Fish Facility. This will be a firm-fixed price construction contract. Construction magnitude is estimated to be between $100,000 and $250,000. The period of performance is 4 months. The North American Industry Classification System (NAICS) code for this project is 237990 and the associated small business size standard is $45,000,000.00. This sources-sought announcement is being issued to identify small business concerns with the capability to accomplish the work. This is not a solicitation. Only those firms responding to this announcement by submitting the following information will be used in determining whether to set aside this requirement. Please provide the following: A capability statement expressing interest in this requirement, describing your company and its capability to complete a project of this magnitude and complexity. Include a statement detailing any special qualifications and certifications, applicable to the scope of this project, held by your firm and/or in-house personnel. A statement or list of your firm's current or past technical experience similar to or the same as the summary scope of work and construction magnitude for this requirement. Include a brief description of each project scope, schedule, and dollar value, and a point of contact name, phone number and email address for the contracting organization. A statement of your firm's business size and type (HUBZone, Service-Disabled Veteran Owned, 8(a), small business). A statement of your firm's bonding capacity Submit this information to Richard Bonnell, Contract Specialist, via email at richard.w.bonnell@usace.army.mil. Your response to this notice must be received, via email, on or before 3:00PM local time on 19 January 2025. This project will add new security barriers (fence, gate,) for additional personnel safety and project security. The contractor selected to perform this work will be required to perform work to include: Concrete saw cutting for electrical underground trench. Sidewalk concrete demolition and new sidewalk concrete Miscellaneous concrete footings Installation of Misc Bollards Select fence demolition Asphalt Repair Remove existing vehicular swing gate and install motor-operated cantilevered gate Install fence and pedestrian gate around base of existing exterior staircase. Install, rigid metallic conduit and undergroundSCH40 PVC conduit, as shown in the plans The Contractor will be responsible for establishing and managing an effective on-site Safety and Health program in accordance with EM 385-1-1 that will require the development and submission of a comprehensive project specific Accident Prevention Plan for Government acceptance. In addition, the Contractor will be required to develop and submit for Government acceptance Activity Hazard Analyses for each phase of work and a project specific Fall Protection Plan that comply with EM 385-1-1. A Site Safety and Health Officer (SSHO) employed by the prime contractor shall be required for each shift of the contractor's on-site operations. The SSHO shall possess a minimum of 5-years' experience in construction safety on similar projects, shall have completed the 30-Hour OSHA Construction Safety training within the last 5-years, and shall have completed at least 24-hours of formal safety training each year for the past 5-years. The Contractor will be responsible for establishing and managing an effective Contractor Quality Control (CQC) System that will require the development and submission of a comprehensive project specific CQC Plan for Government acceptance. A CQC System Manager employed by the prime contractor shall be required to be on-site for each shift of the Contractor's operations. The CQC System Manager must possess a minimum of 5-years relevant experience in a supervisory or management position such as Quality Control Manager, Quality Assurance Manager, or Construction Manager directly involved in the management of construction quality at the project site. In addition, the CQC System Manager shall have completed the course entitled "Construction Quality Management for Contractors" within the last 5-years. The Contractor will be required to use the Government-furnished Construction Contractor Module (referred to as QCS) of the Resident Management System (RMS) to record, maintain, and submit various information throughout the contract period. QCS is a Windows-based program that can be run on a stand-alone personal computer or on a network. The Government will make the QCS software available to the Contractor after contract award. The project will involve the development and management of Contractor furnished submittals for items such as pre-construction plans, product data, test reports, and contract close-out documentation as required by the technical specifications of the contract. Miscellaneous work within the project includes the delivery of As-Built Drawings. Contracting Office Address: USACE District, Walla Walla, 201 N. Third Avenue, Walla Walla, WA 99362- 1876 Place of Performance: Little Goose Lock and Dam, Dayton, Washington (near Starbuck Washington)

From Sources Sought posted on Jan 06, 2026

The U.S. Army Corps of Engineers, Walla Walla District is seeking small business sources for a construction project entitled Little Goose Visual Monitoring Project Security Upgrades The work is located near Starbuck, Washington at the Little Goose Lock and Dam, Juvenile Fish Facility. This will be a firm-fixed price construction contract. Construction magnitude is estimated to be between $100,000 and $250,000. The period of performance is 4 months. The North American Industry Classification System (NAICS) code for this project is 237990 and the associated small business size standard is $45,000,000.00. This sources-sought announcement is being issued to identify small business concerns with the capability to accomplish the work. This is not a solicitation. Only those firms responding to this announcement by submitting the following information will be used in determining whether to set aside this requirement. Please provide the following: A capability statement expressing interest in this requirement, describing your company and its capability to complete a project of this magnitude and complexity. Include a statement detailing any special qualifications and certifications, applicable to the scope of this project, held by your firm and/or in-house personnel. A statement or list of your firm's current or past technical experience similar to or the same as the summary scope of work and construction magnitude for this requirement. Include a brief description of each project scope, schedule, and dollar value, and a point of contact name, phone number and email address for the contracting organization. A statement of your firm's business size and type (HUBZone, Service-Disabled Veteran Owned, 8(a), small business). A statement of your firm's bonding capacity Submit this information to Richard Bonnell, Contract Specialist, via email at richard.w.bonnell@usace.army.mil. Your response to this notice must be received, via email, on or before 3:00PM local time on 19 January 2025. This project will add new security barriers (fence, gate,) for additional personnel safety and project security. The contractor selected to perform this work will be required to perform work to include: Concrete saw cutting for electrical underground trench. Sidewalk concrete demolition and new sidewalk concrete Miscellaneous concrete footings Installation of Misc Bollards Select fence demolition Asphalt Repair Remove existing vehicular swing gate and install motor-operated cantilevered gate Install fence and pedestrian gate around base of existing exterior staircase. Install, rigid metallic conduit and undergroundSCH40 PVC conduit, as shown in the plans The Contractor will be responsible for establishing and managing an effective on-site Safety and Health program in accordance with EM 385-1-1 that will require the development and submission of a comprehensive project specific Accident Prevention Plan for Government acceptance. In addition, the Contractor will be required to develop and submit for Government acceptance Activity Hazard Analyses for each phase of work and a project specific Fall Protection Plan that comply with EM 385-1-1. A Site Safety and Health Officer (SSHO) employed by the prime contractor shall be required for each shift of the contractor's on-site operations. The SSHO shall possess a minimum of 5-years' experience in construction safety on similar projects, shall have completed the 30-Hour OSHA Construction Safety training within the last 5-years, and shall have completed at least 24-hours of formal safety training each year for the past 5-years. The Contractor will be responsible for establishing and managing an effective Contractor Quality Control (CQC) System that will require the development and submission of a comprehensive project specific CQC Plan for Government acceptance. A CQC System Manager employed by the prime contractor shall be required to be on-site for each shift of the Contractor's operations. The CQC System Manager must possess a minimum of 5-years relevant experience in a supervisory or management position such as Quality Control Manager, Quality Assurance Manager, or Construction Manager directly involved in the management of construction quality at the project site. In addition, the CQC System Manager shall have completed the course entitled "Construction Quality Management for Contractors" within the last 5-years. The Contractor will be required to use the Government-furnished Construction Contractor Module (referred to as QCS) of the Resident Management System (RMS) to record, maintain, and submit various information throughout the contract period. QCS is a Windows-based program that can be run on a stand-alone personal computer or on a network. The Government will make the QCS software available to the Contractor after contract award. The project will involve the development and management of Contractor furnished submittals for items such as pre-construction plans, product data, test reports, and contract close-out documentation as required by the technical specifications of the contract. Miscellaneous work within the project includes the delivery of As-Built Drawings. Contracting Office Address: USACE District, Walla Walla, 201 N. Third Avenue, Walla Walla, WA 99362- 1876 Place of Performance: Little Goose Lock and Dam, Dayton, Washington (near Starbuck Washington)

From Sources Sought posted on Jan 13, 2026

Notice history

2
  1. Sources Sought Posted Jan 06, 2026
  2. Sources Sought LATEST Posted Jan 13, 2026
    • Response Deadline: Jan 19, 2026Jan 20, 2026

Details

Solicitation number W912EF26RSS06
Notice ID 839ede5e109644e2bfc34ed7a10fab4c
Notice type Sources Sought
Place of performance Lacrosse, Washington
Archive date Feb 03, 2026

Award Information

Not yet awarded

Documents

1
View on SAM.gov

Contacts

primary
Richard W. Bonnell

Email

secondary
Cynthia Jacobsen

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE ARMY
US ARMY CORPS OF ENGINEERS
ENGINEER DIVISION NORTHWESTERN
ENDIST WALLA WALLA
US ARMY ENGINEER DISTRICT WALLA WAL

Place of Performance

Lacrosse, Washington
USA

Dates

Posted Jan 06, 2026 7 months ago
Last Updated Aug 06, 2026 1 day ago