LCO2 Tank FA560626QA023
Summary
AI-generated · Apr 02, 2026Provide a liquid CO2 storage tank with a 6,000–7,000 liter capacity, featuring a vacuum-insulated double-wall design: an inner low-temperature resistant austenitic stainless steel vessel and an outer carbon steel vessel with an anti-corrosion primer and topcoat. The interspace is filled with perlite insulating powder and an absorbent to maintain a vacuum pressure below 0.05 millibar during operation. The inner vessel must withstand up to 22 bar gauge over the specified temperature range from -196°C to 20°C, and it should deliver pressurized LCO2 at 189–261 psi (13–18 bar) to a Dry Ice Production Hub via a flexible hose attachment. Include a safety valve system to prevent overpressurization and a safety shutoff valve.
Manufacture and test the tank in accordance with EU 97/23/EC and EN 13458. The supplier’s Quality Management System must satisfy EN ISO 9001/2000 or ASME (U, U2, R-Stamp). The inquiry also asks whether a specialized foundation is required to safely support long-term positioning of the tank, and, if so, what specifications such a foundation would need. This is an information request; feedback is encouraged and formal bids or quotes are not being sought at this time.
Spangdahlem AB is conducting market research for the below requirement. Be advised, this is NOT a solicitation, nor does it guarantee a solicitation for this requirement to be posted in the future. This is an official request for information (RFI) to notify prospective offerors. Feedback is encouraged. Quotes are not currently being requested. Currently, there is no specialised foundation for the LCO2 tank to stand upon: is a specialised foundation required and if so, what specifications would such a foundation have to fulfill to safely support a long-term positioning of a LCO2 tank? The purpose of this requirement is to provide a liquid CO2 storage tank with the following draft-requirements: The tank should have a capacity of 6,000 - 7,000 liters and be a vacuum-insulated double wall tank consisting of two concentric vessels, a low-temperature resistant austenitic steel inner tank and an outer tank made of carbon steel with an anti-corrosion primer and a top coat of paint. The interspace between the two tanks should be filled with perlite insulating powder and an absorbent to maintain a vacuum pressure of < 0.05 millibar during tank operation. The maximum allowable working pressure for the inner vessel must be 22 bar gauge for temperatures ranging from -196 up to 20C. It must supply pressurized LCO2 at 189-261 psi (13-18 bar) to a Dry Ice Production Hub through a flexible hose attachment. It will include a safety valve system to prevent overpressurizaton and a safety shutoff valve. The tank must be manufactured and tested in accordance with EU 97/23/EC and EN 13458. The company's Quality Management System must satisfy all elements of the EN ISO 9001/2000 program or ASME (U, U2, R-Stamp).
From Sources Sought posted on Apr 01, 2026Notice history
1Details
Award Information
Not yet awarded
Contacts
Phone
Phone
Agency
Place of Performance
DEU