Kentucky Lock Lift Pump Station Repair/Replacement W912P5-26-Q-KLSR

Solicitation W912P5-26-Q-KLSR Copied Notice ID 3fa39b077e484161a17dc90f7b1e2274 Copied DEPT OF DEFENSE — W072 ENDIST NASHVILLE
SAM.gov
Posted
Dec 15, 2025
Deadline
Dec 29, 2025
Set-aside
SBA
NAICS
238210
PSC
Y1KA

Summary

AI-generated · Dec 16, 2025

Install two new lift-station pumps (40 GPM, 108 ft TDH, 5.0 HP, 3450 RPM, 460/3/60 Hz) at the Lock Wall lift station and furnish all materials, tools, equipment, transportation, supervision, quality control, and labor. Damaged pump supports must be replaced or repaired, and the Conery base must be evaluated for reuse with replacement if needed. Include safe pumping and removal of existing waste as required to perform the work. The existing system includes two grinder pumps; one has already been removed and replaced, and the contractor shall repair the removed Zoeller G7112 pump to full functionality. The transducer, two check valves (Flomatic 508/3235), and two ball valves (Flomatic SSBV1000-20) inside the wet well must be repaired/replaced in-kind, and the operation of the ball valves with the extension handle must be verified.

A functionality test must be performed to confirm: both pumps run automatically via the transducer and via the float system, and the pumps automatically switch from transducer to float if the transducer fails. Test procedures for the functionality test must be submitted for government review and approval. The work is expected to be completed within 30 calendar days of award at the Kentucky Lock Resident Office in Grand Rivers, KY. This is a market-research (sources sought) activity to determine competitive basis; responses should be submitted through the market survey.

Request for Information: The Government is issuing this Request for Information to determine a competitive basis for the procurement described. This is not a solicitation. No reimbursement will be made for any costs associated with providing information in response to this survey. This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information. Requirement: Contractor shall furnish all materials, supplies, tools, equipment, transportation, supervision, quality control, and labor necessary to complete this Scope of Work. All materials and workmanship will be manufactured and accomplished according to industry standards and specifications. For additional information, reference the attached document, Lock Wall Lift Station Pump Repairs Reference Document . Two (2) new pumps, 40 GPM and 108 feet TDH, 5.0 HP, 3450 RPM, 460/3/60 Hz will be procured and installed within the Lock Wall lift station. The existing pump supports within the lift station are damaged and new pump supports will need to be installed. The contractor shall also verify if the Conery base can be reused without modification. If not, the contractor will be responsible for replacing the base. Costs estimated for this work shall include any pumping/removal of existing waste in the lift station that is required to complete this task safely. Reference the provided reference document for additional details related to existing utilities associated with the lift station. The existing lift station contains two (2) grinder pumps. One of the existing pumps has been removed and replaced. The removed pump shall be repaired to full functionality. The removed pump is a Zoeller Model G7112, 7.5 HP, 3450 RPM, 460/3/60 Hz, submersible high head grinder pump complete with 2 inch horizontal discharge flange that is adaptable to 3-inch, SC/SC lower seal, 7.125-inch diameter impeller complete with 25-feet power & control cable. The contractor shall repair or replace the transducer associated with the lift station pump. The currently installed transducer is precision digital PDA6420 Split Core AC Current Transducer. The contractor shall replace in-kind the 2 check valve inside the wet well. The existing check valve is Flomatic Check Valves Model 508 Part Number 3235. The contractor shall replace in-kind the 2 ball valve inside the wet well. The existing ball valve is Flomatic Ball Valves Part Number SSBV1000-20. Verify operation of the new ball valve with the extension handle. The Contractor shall perform a functionality test to ensure the system works as intended. Test procedures describing the functionality test shall be submitted to the Government for review and approval. The following functions shall be tested to verify that they are functioning as intended by design: Both pumps automatically run via the transducer system. Both pumps automatically run via the float system. The pumps automatically switch from the transducer system to the float system if the transducer system fails. Period of Performance: The Period of Performance shall be performed within 30 calendar days of the award date. Place of Performance: Kentucky Lock Resident Office 193 Taylor Park Rd. Grand Rivers, KY 42045 NAICS: The anticipated NAICS code for this requirement is 238210 (Electrical Contractors and Other Wiring Installation Contractors) with a size standard of $19,000,000. Survey: Please send responses to the Market Survey to Samantha Clay at Samantha.J.Clay@usace.army.mil and Cierra Vega at Cierra.R.Vega@usace.army.mil by 12:00PM CT on December 29, 2025. Name of Firm: CAGE: Point of Contact (include email address) Are you classified as a small business under any of the following NAICS code: 238210 (Electrical Contractors and Other Wiring Installation Contractors) 5. If this requirement is advertised, do you anticipate submitting a quote? 6. List three (3) projects completed within ten (10) years of the date of this notice that demonstrates experience with electrical and wiring installation: Project Name / General Description: Contract Number (if applicable): Dollar Amount: Project Name / General Description: Contract Number (if applicable): Dollar Amount: Project Name / General Description: Contract Number (if applicable): Dollar Amount:

From Sources Sought posted on Dec 15, 2025

Notice history

1
  1. Sources Sought LATEST Posted Dec 15, 2025 View

Details

Solicitation number W912P5-26-Q-KLSR
Notice ID 3fa39b077e484161a17dc90f7b1e2274
Notice type Sources Sought
Product / Service (PSC) Y1KA
NAICS 238210
Place of performance Grand Rivers, Kentucky
Archive date Jan 13, 2026

Award Information

Not yet awarded

Documents

No files available

View on SAM.gov

Contacts

primary
Samantha Clay

Email

Phone

secondary
Cierra Vega

Email

Phone

Agency

DEPT OF DEFENSE
DEPT OF THE ARMY
US ARMY CORPS OF ENGINEERS
ENGINEER DIVISION GREAT LAKES AND OHIO
ENDIST NASHVILLE
W072 ENDIST NASHVILLE

Place of Performance

Grand Rivers, Kentucky
USA

Dates

Posted Dec 15, 2025 7 months ago
Last Updated Aug 06, 2026 1 day ago
Due Dec 29, 2025 7 months ago